8 | M-10 Instruction Guide M-10 Instruction Guide | 9
FREQUENCY BAND CHART
Digits displayed Country
EC 40CH FM 4W
EU Europe 40CH FM 4W / 40CH AM 1W
I2 Italy 34CH AM/FM 4W
IT Italy 40CH AM/FM 4W
PL Poland 40CH AM/FM 4W
D3 Germany 80CH FM 4W /40CH AM 1W
D4 Germany 80CH FM 4W /40CH AM 4W
UK England 40CH FM 4W UK frequencies + EC 40CH FM 4W
FOR EXTRA EU MARKET ONLY
PX Poland 400CH AM/FM 4W Polish frequencies
RU Russia 400CH AM/FM 4W
PC Private Channels 50CH AM/FM
TECHNICAL SPECIFICATIONS
GENERAL
Channels ...................................................................... (see the frequency band chart)
Frequency Range* .................................................................. 26.565-27.99125 MHz
Duty cycle (% on 1 hour) ......................................... TX 5% - RX 5% - Stand-by 90%
Frequency Control ....................................................................................................PLL
Operating Temperature Range ..................................................................-10°/+55° C
DC input voltage ..................................................................................12.6V DC ±10%
Size...........................................................................................................122x35x195mm
Weight ...................................................................................................................... 820 g
RECEIVER
Receiving system ..................................................... dual conversion superheterodyne
Intermediate frequency ......................................I° IF: 10.695 MHz • II° IF: 455 KHz
Sensitivity ..................................................................................≤ 1µV for 20 dB SINAD
Audio output power @10% THD ..........................................................4W @ 8 Ohm
Audio distortion ............................................................................less than 8% @ 1 KHz
Image rejection ........................................................................................................65 dB
Adjacent channel rejection ....................................................................................65 dB
Signal/Noise ratio ....................................................................................................45 dB
Current drain at stand/by.................................................................................< 250mA
TRANSMITTER
Output power ......................................................................................................4W max
Modulation ................................................................................FM: 1,8 KHz ± 0,2 KHz
..........................................................................................................................AM: ≥ 90%
Frequency response ............................................................................... 300 Hz/3 KHz
Output impedance .................................................................RF 50 Ohm unbalanced
Signal/Noise Ratio ........................................................................................ 40 dB MIN
Current drain ....................................................................................................... 1100mA
* covering all approved EU frequency bands
Specifications are subject to change without notice.
A readily accessible disconnect device shall be incorporated in the installation wiring.
The disconnect device shall disconnect both poles simultaneously.
12

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Midland M10 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info