HOW TO MAINTAIN
Ceiling cassette −4 way Compact (600 x 600 mm)− (FDTC)
1. Slide the inlet grille levers in the direction of the
arrow (
), and open it downwards.
2. Turn the inlet grille stopper.
3. Pull the filter toward you.
4. When the filter is put in place, insert the filter into
the hooks on the inlet grille, and be sure to return
the stopper to its original position.
5. When putting the inlet grille back in place, slide the
levers in the opposite direction and check to be
sure that the grille does not come open.
Hooks
Hooks
Stopper
HOW TO MAINTAIN
Air filter is attached when the air conditioner is installed, so consult your dealer about how to remove or clean it.
Duct connected −High static pressure− (FDU)
Duct connected −Middle static pressure− (FDUM)
Duct connected (Ultra thin) −Low static pressure− (FDQS)
Duct connected −Compact & Flexible− (FDUH)
Duct connected −High static pressure Out door Air processing unit (FDU -F)
Duct connected −Low static pressure− (FDUT)
Floor standing -2way- (FDFW)
<How to open, close the inlet panel>
Open
Place fingers at the recesses on both sides of the panel
and pull down the panel forward so that it will be open by
about 15°.
Close
Push both ends evenly and press further lightly at the
center.
Ceiling cassette −1 way− (FDTS)
1. Slide the lever of the suction grille in the arrow ( ) direction
to open the grille.
2. While light pushing up, remove the filter from the tabs at the
left and righit, and pull towards the front
.
Ceiling cassette −1 way compact− (FDTQ)
1. Slide the lever of the suction grille in the arrow ( ) direction
to open the grille.
2. While light pushing up, remove the filter from the tabs at the
left and righit, and pull towards the front
.
Air filter
Ta b
Suction grille
Tabs
Air filter
Ta b
Suction grille
Tabs
<How to remove, install the inlet panel>
Remove
When removing the panel for internal cleaning or others,
open the panel, remove the string and then pull it forward.
Install
Secure the upper edge of the panel by lightly pushing it
in, place the string as illustrated and then close the panel.
<How to remove, install the filter>
Remove
1. Pull up the air inlet panel forwards.
2. Lightly hold the knobs at the both sides and lift a little to
remove the panel forward.
Install
1.
Hold firmly the filter at the both sides as shown at right
and insert securely.
2.
Close the air inlet panel.
Floor standing (with casing) (FDFL)
Remove the front panel and pull the air filter out from the
bottom of the unit.
Floor standing (without casing) (FDFU)
Pull the air filter out from the bottom of the unit.
Wall mounted (FDK)
1.
Pull up the suction grille forward.
Hold the concave sections at both the righit and left side
with your hands and pull the suction grille forward.
It stops while being open at about 60
°
.
2.
Lightly hold the handle of the air filter , slightly lift it upward,
and then pull it out forward.
When mounting, press the lever forward untill it snaps.
When morrting, snab the filter into the tabs of inlet grille.
Ceiling suspended (FDE)
1. Slide the lever of the inlet grille backward ( direction) and
open it downwards.
2. Pressing the inlet grille, press the filter to remove it from the
tab and pull it
downwards.
Air filter
tabs
Ceiling cassette −2 way− (FDTW)
1. Push one side of the inlet panel (pin A side) upward.
2. Disengage the panel from pin A.
3. Disengage the panel from the pin B and remove the panel.
4. Press the air filter and turn the stopper to remove the air
filter.
e
Disengage the pin B side.
c Push the pin A side upward.
d Disengage the pin A side.
Pin B Pin A
Panel
Stopper
Number of stoppers
FDTW 28 - 71 6pc.
FDTW 90-140 10pc.
Caution
Install the air filter in the correct order.
Tu r n
18

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Mitsubishi FDFU wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Mitsubishi FDFU

Mitsubishi FDFU Bedienungsanleitung - Deutsch - 22 seiten

Mitsubishi FDFU Bedienungsanleitung - Holländisch - seiten

Mitsubishi FDFU Bedienungsanleitung - Französisch - 22 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info