583413
4
Zoom out
Zoom in
Vorherige Seite
1/19
Nächste Seite
2
Do not touch the aluminum fin.
Otherwise it may lead to injuries.
Do not clean the inside of the indoor unit by yourself.
Make sure to consult your dealer or user inquiry
counter specified by our company.
If you select incorrect detergent or improper method, resin parts
may be damaged and lead to water leakage. If the detergent is
dropped on the electric component or motor, it may lead to failure,
smoking or ignition.
Do not place objects on the outdoor unit, nor mount on
it.
It may lead to injuries resulting from dropping or falling.
During the operation or maintenance, do not use an
unstable footrest.
It may lead to injuries resulting from falling.
During thunderstorm, stop the operation and turn off
the switch.
A lightning strike may lead to failure.
After several seasons of operating, inspections and
maintenances are required except routine care and
cleaning.
Accumulated dirt or dust inside the indoor unit may cause odor,
water leakage through the clogging of water discharging pipe for
dehumidification. Specialized information and skills are required for
inspections and maintenances. Therefore contact your dealer.
Do not place any object around the outdoor unit, nor
allow fallen leaves to pile up.
Fallen leaves may induce insects and worms in them, and
they may lead to failure, ignition or smoking by touching electric
components.
Do not use with inlet/outlet grilles or other panel
removed.
Otherwise, it may lead to injuries.
Do not operate or stop the unit by using the power
supply switch.
It may lead to fire or water leakage.
If auto restart is set effectively, the fan may rotate suddenly
causing injuries.
Do not touch blowout port when the swing louver
moves.
Otherwise, it may lead to injuries.
Do not strain the remote control cord.
A part of core wire may be cut off causing electric leakage.
Do not use water heater etc. near the indoor unit or
remote control.
If a Vapor-generating appliance is used near them, it may
lead to water drop causing electric leakage or short circuit.
Do not use the unit where powder or fiber is floating.
Fine powder or fiber passing through the air filter may
stagnate inside the unit and lead to electric leak or short
circuit.
Do not place objects under the unit which must avoid
being exposed to water.
Over 80 percent humidity or the clogging of drain pipe may
damage them through dew dropping.
Never perform any modification. Contact your dealer for
repairing.
Improper repairing may lead to water leakage, electric
shock or fire. Normally the refrigerant does not leak. But if it leaks
and contacts fire such as fan heater, space heater or cooking
heater, it may produce toxic chemicals. When repairing refrigerant
leakage, determine the service with the service staff that the repair
has been finished without fault.
If it is required to relocation and reinstall the unit, consult
your dealer or a specialist.
Improper installation of air conditioning unit may cause
water leakage, electric shock and/or fire.
Before repairing or checking indoor unit, be sure to turn
off “Indoor unit power supply breaker”.
It can result in electric shock or injury due to rotation of
indoor unit fan if you perform check or repair with the “Indoor unit
power supply breaker” turned on.
Place the panels removed for repairing or checking on
the stable spot.
Otherwise, dropping or falling may lead to injury.
CAUTION
PRECAUTIONS FOR RELOCATION OR REPAIRING
PRECAUTIONS FOR WASTE DISPOSAL
Your Air Conditioning product may be marked with this symbol. It means that waste electrical and electronic
equipment (WEEE as in directive 2002/96/EC) should not be mixed with general household waste. Air
conditioners should be treated at an authorized treatment facility for re-use, recycling and recovery and
not be disposed of in the municipal waste stream. Please contact the installer or local authority for more
information.
Ventilation display
Displayed during ventilation operation
See page 10
Weekly timer display
Displays the settings of the
weekly timer.
Operation setting display area
Displays setting temperature, airflow
volume, operation mode and operation
message.
Operation/check indicator light
During operation: Lit in green
In case of error: Flashing in red
Operation/stop button
This button is used to operate and stop
the air conditioning system.
Press the button once to operate the
system and press it once again to stop
the system.
MODE button
This button is used to change the
operation mode.
FAN SPEED button
This button is used to set the airflow
volume.
VENT button
This button is used to operate external
ventilator. See page 10
LOUVER button
This button is used to operate/stop the
swing louver. See page 9
SET button
•This button is used to fix the setting.
•This button is used to set the silent mode.
See page 3 to 10
RESET button
•Press this button while making settings to go back to the
previous operation. See page 3 to 10
•This button is also used to reset the “FILTER CLEANING” display.
(Press it after cleaning the air filter)
Central control display
Displayed when the air conditioning system is
controlled by centralized remote control.
Timer operation display
Displays the timer operation setting.
Temperature setting buttons
These buttons are used to set the
temperature of the room.
Timer button
This button is used to set
the timer mode.
See page 3
Timer setting buttons
These buttons are used to set
the timer mode and the time.
See page 3 to 10
GRILL button
This button has no function.
When this button is pressed,
(Invalid Operation)
is displayed,but it does not mean a failure.
AIR CON No. button
•Display the indoor unit number connected to this
remote control.
•This button is used for indoor unit address setting.
CHECK button
This button is used at servicing.
TEST button
This button is used during test operation.
NAMES AND FUNCTIONS OF REMOTE CONTROL BUTTONS
(WIRED REMOTE CONTROL)
Wired remote control
• The figure below shows the remote control with the cover opened. Note that the items in the liquid
crystal display (LCD) area are shown for explanation purpose.
Pull the cover downwards to open.
HOW TO USE< WIRED REMOTE CONTROL >
PSA012B735A_B_EN.indd 2PSA012B735A_B_EN.indd 2 2010-6-30 9:35:062010-6-30 9:35:06
4

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Mitsubishi RC-E5 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Mitsubishi RC-E5

Mitsubishi RC-E5 Bedienungsanleitung - Holländisch - 18 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info