604710
101
Zoom out
Zoom in
Vorherige Seite
1/103
Nächste Seite
-
100
-
'13 • SRK-T-144
Model SRK50ZMX-S
( 4/ )
Information to identify the model(s) to which the information relates to: If function includes heating: Indicate the heating season the
Indoor unit model name SRK50ZMX-S information relates to. Indicated values should relate to one
Outdoor unit model name SRC50ZMX-S heating season at a time. Include at least the heating season 'Average'.
Function(indicate if present) Average(mandatory) Yes
cooling Yes Warmer(if designated) No
heating Yes Colder(if designated) No
Item symbol value unit Item symbol value class
Design load Seasonal efficiency and energy efficiency class
cooling Pdesignc 5.00 kW cooling SEER 6.70 A++
heating / Average Pdesignh 5.30 kW heating / Average SCOP/A 4.60 A++
heating / Warmer Pdesignh - kW heating / Warmer SCOP/W - -
heating / Colder Pdesignh - kW heating / Colder SCOP/C - -
unit
Declared capacity at outdoor temperature Tdesignh Back up heating capacity at outdoor temperature Tdesignh
heating / Average (-10
) Pdh 4.85 kW heating / Average (-10
) elbu 0.45 kW
heating / Warmer (2
) Pdh - kW heating / Warmer (2
) elbu - kW
heating / Colder (-22
) Pdh - kW heating / Colder (-22
) elbu - kW
Declared capacity for cooling, at indoor temperature 27(19)
and Declared energy efficiency ratio, at indoor temperature 27(19)
and
outdoor temperature Tj outdoor temperature Tj
Tj=35
Pdc 5.00 kW Tj=35
EERd 3.85 -
Tj=30
Pdc 3.68 kW Tj=30
EERd 5.80 -
Tj=25 Pdc 2.37 kW Tj=25 EERd 9.90 -
Tj=20
Pdc 3.60 kW Tj=20
EERd 8.70 -
Declared capacity for heating / Average season, at indoor Declared coefficient of performance / Average season, at indoor
temperature 20
and outdoor temperature Tj temperature 20
and outdoor temperature Tj
Tj=-7
Pdh 4.69 kW Tj=-7
COPd 2.80 -
Tj=2
Pdh 2.85 kW Tj=2
COPd 4.75 -
Tj=7
Pdh 1.83 kW Tj=7
COPd 5.75 -
Tj=12
Pdh 1.16 kW Tj=12
COPd 6.65 -
Tj=bivalent temperature Pdh 4.69 kW Tj=bivalent temperature COPd 2.80 -
Tj=operating limit Pdh 5.11 kW Tj=operating limit COPd 2.70 -
Declared capacity for heating / Warmer season, at indoor Declared coefficient of performance / Warmer season, at indoor
temperature 20
and outdoor temperature Tj temperature 20
and outdoor temperature Tj
Tj=2
Pdh - kW Tj=2
COPd - -
Tj=7 Pdh - kW Tj=7 COPd - -
Tj=12
Pdh - kW Tj=12
COPd - -
Tj=bivalent temperature Pdh - kW Tj=bivalent temperature COPd - -
Tj=operating limit Pdh - kW Tj=operating limit COPd - -
Declared capacity for heating / Colder season, at indoor Declared coefficient of performance / Colder season, at indoor
temperature 20
and outdoor temperature Tj temperature 20
and outdoor temperature Tj
Tj=-7
Pdh - kW Tj=-7
COPd - -
Tj=2
Pdh - kW Tj=2
COPd - -
Tj=7 Pdh - kW Tj=7 COPd - -
Tj=12
Pdh - kW Tj=12
COPd - -
Tj=bivalent temperature Pdh - kW Tj=bivalent temperature COPd - -
Tj=operating limit Pdh - kW Tj=operating limit COPd - -
Tj=-15
Pdh - kW Tj=-15
COPd - -
Bivalent temperature Operating limit temperature
heating / Average Tbiv -7
heating / Average Tol -15
heating / Warmer Tbiv - heating / Warmer Tol -
heating / Colder Tbiv -
heating / Colder Tol -
Cycling interval capacity Cycling interval efficiency
for cooling Pcycc - kW for cooling EERcyc - -
for heating Pcych - kW for heating COPcyc - -
Degradation coefficient Degradation coefficient
cooling Cdc 0.25 - heating Cdh 0.25 -
Electric power input in power modes other than 'active mode'
Annual electricity consumption
off mode Poff 5 W cooling Qce 262 kWh/a
standby mode Psb 5 W heating / Average Qhe 1614 kWh/a
thermostat-off mode Pto 45 W heating / Warmer Qhe - kWh/a
crankcase heater mode Pck 0 W heating / colder Qhe - kWh/a
Capacity control(indicate one of three options) Other items
Sound power level(indoor) Lwa 60 dB(A)
Sound power level(outdoor) Lwa 63 dB(A)
fixed No Global warming potential GWP 1975 kgCO2eq.
staged No Rated air flow(indoor) - 810 m3/h
variable Yes Rated air flow(outdoor) - 2340 m3/h
Contact details for obtaining Name and address of the manufacturer or of its authorised representative.
more information Mitsubishi Heavy Industries Air-Conditioning Europe, Ltd.
7 Roundwood Avenue, Stockley Park, Uxbridge, Middlesex, UB11 1AX,
United Kingdom
B RWA000Z252-3
B
RWA000Z252B
101

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Mitsubishi SRK35ZMX-S wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Mitsubishi SRK35ZMX-S

Mitsubishi SRK35ZMX-S Bedienungsanleitung - Deutsch - 34 seiten

Mitsubishi SRK35ZMX-S Bedienungsanleitung - Englisch - 34 seiten

Mitsubishi SRK35ZMX-S Bedienungsanleitung - Holländisch - 34 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info