18 Video outputs as BNC jacks to connect monitors
19
DMR-180 / DMR-184:
audio inputs AIN 1 4 for the channels CH 1 4
as RCA jacks to connect the audio outputs of
cameras with microphones;
DMR-188
only has one audio input which can be
assigned to the desired video input in the setting
menu
20 Audio outputs as RCA jacks, e. g. to connect the
audio inputs of monitors
21 USB port to connect the mouse provided
22 USB port to connect an external storage
medium (USB stick or hard disk) for data backup
or for processing the video recordings
23 Jack LAN to connect a computer network (Ether-
net) for remote control via a computer
24 Terminals
RS485 + /
-
:
data bus for PTZ control of cameras (
chap-
ter 11)
SENSOR 1 4 (
DMR-188:
Sensor 1 8):
connections for sensors triggering an alarm (e. g.
motion detectors;
chapter 10.1)
ALARM:
output for units processing an alarm (e. g. signal
devices)
25 Jack VGA to connect a computer monitor with
VGA input
26 Jack DC 12 V for power supply via the power
supply unit provided and connected to 100 240 V~ /
50 – 60 Hz
1.3 Infrared remote control
27 Buttons 0 9 to display the corresponding chan-
nel (CH 1 to CH 4 or
for DMR-188:
CH 1 to CH 8)
as a full image; in the setting menu, to enter num-
bers
28
DMR-180 / DMR-184:
button ALL to change from full image display of a
channel to the quadrant display of all channels
DMR-188:
to change from full image display of a channel to
the display of several channels; each time the
button is pressed, the view will switch between
the quadrant display of the channels CH 1 to
CH 4, CH 5 to CH 8 and the simultaneous display
of all eight channels
29 Buttons , , and to select a menu item,
an input field, a list entry, an inserting position or
a button
30 Button AUDIO / SEARCH without function
31 Buttons for the recorder functions:
start or continuation of replay
interruption of replay (
PAUSE), sequential
frames (FRAME); activation / deactivation of
the sequence function
replay at 2-fold, 4-fold or 8-fold forward
speed
replay at 2-fold, 4-fold or 8-fold reverse
speed
manual start of a recording
end of replay or of a recording started manu-
ally
32 Button MENU to activate / deactivate the main
menu, to deactivate submenus or an input field
33 Button SEL to activate the menu list or a sub-
menu and to confirm a selection or input
34 Button MUTE without function
35 Battery compartment latch
36 Battery compartment cover
2 Safety Notes
The units (video recorder and power supply unit)
correspond to all required directives of the EU and
are therefore marked with .
Please observe the following items in any case:
G
The units are suitable for indoor use only. Protect
them against dripping water and splash water,
high air humidity and heat (admissible ambient
temperature range 0 40 °C).
G
Do not place any vessel filled with liquid on the
units, e. g. a drinking glass.
G
The heat generated within the video recorder must
be dissipated by air circulation. Therefore, the air
vents of the housing must not be covered.
G
Do not operate the units and immediately discon-
nect the mains plug of the power supply unit from
the socket
1. if one of the units or the mains cable is visibly
damaged,
2. if a defect might have occurred after a unit was
dropped or suffered a similar accident,
3. if malfunctions occur.
In any case the units must be repaired by skilled
personnel.
G
Never pull the mains cable for disconnecting the
mains plug from the socket, always seize the plug.
G
For cleaning only use a dry, soft cloth; never use
water or chemicals.
G
No guarantee claims for the units and no liability
for any resulting personal damage or material
damage will be accepted if the units are used for
other purposes than originally intended, if they are
not correctly connected or operated, or if they are
not repaired in an expert way. Likewise, no liability
will be accepted for operating errors or for data
loss caused by a defect and for consequential
damage of this data loss.
3 Applications
The digital video recorders DMR-180, DMR-184 and
DMR-188 are specially designed for applications in
video surveillance systems. Recordings of up to 4
(DMR-180 and DMR-184) or 8 (DMR-188) camera
signals are made on a hard disk of 1 TB max.
according to the highly efficient H.264 compression
procedure. DMR-180 is already equipped with a
250 GB hard disk and is supplied with two cameras
with infrared LEDs and connection cables in the set
DMR-180SET.
The features of the recorder include, among others:
3 recording qualities
audio recording for 4 channels (DMR-180 and
DMR-184) or 1 channel (DMR-188)
4 recording modes: started manually, time-con-
trolled, triggered by external alarm signal or by the
internal motion detector
image corrections to be adjusted separately for
each camera channel
video motion detector to be configured differently
for each camera channel
2-stage password protection against unauthorized
operation
2 video outputs and 1 VGA output, 2 audio outputs
(DMR-180, DMR-184) or 1 audio output (DMR-
188)
camera signals to be reproduced individually as a
full image or simultaneously with a split screen
video system to be selected: PAL / NTSC
easy operation via mouse control (mouse pro-
vided)
infrared remote control
4 (DMR-180 and DMR-184) or 8 (DMR-188) alarm
inputs, 1 alarm output
alarm triggering via motion detection, via external
alarm signal, in case of video signal loss or if hard
disk is full or missing
USB 2.0 interface for exporting video files
RS-485 interface for remote control of suitable
cameras (PTZ)
– LAN interface for connection to a computer net-
work / to the Internet
remote access for live surveillance, replay of
recordings and configuration of the recorder
via LAN / Internet by computer or mobile phone
with the software provided or
Windows Internet
Explorer
recording, live surveillance and remote access
possible at the same time
replay of exported recordings via software pro-
vided
4 Installing a Hard Disk
To make video recordings, install a hard disk (con-
nection type SATA, 1 TB max.) first. DMR-180 is
supplied with a 250 GB hard disk already installed
which may also be replaced by a 1 TB hard disk, if
required. To install the hard disk:
1) Disconnect the recorder from the power supply.
2) Release the screws fixing the cover of the hous-
ing, then remove the cover.
3) Connect the plugs of the power supply cable (a)
and of the data cable (b) to the contacts of the
hard disk according to figure 7.
4) Fasten the hard disk to the supporting rails via
two screws each on the right and left sides.
5) Replace the cover of the housing and fasten the
screws again.
5 Connecting Units
Figures 69 and 70 on the last pages of the instruc-
tion manual show an example for connection each
for DMR-180 or DMR-184 and DMR-188; however,
it will not be necessary to use all of the connection
possibilities shown.
Switch off the recorder before connecting any
units or changing any existing connections.
5.1 Video connections
1) Connect the video outputs of the cameras to the
jacks CH 1 CH 4 or CH 1 CH 8 (17).
2) Connect the video input of a monitor to one of the
two jacks VIDEO OUTPUT (18) and / or connect a
computer monitor with VGA input to the jack VGA
(25). The second jack VIDEO OUTPUT (18)
allows to connect another monitor or, for exam-
ple, another video recorder.
5.2 Audio connections
1) For audio recordings and / or live surveillance, the
RCA input jacks AIN1 AIN4 (19) allow to con-
nect, for example, the audio outputs of cameras
with integrated microphones or the preamplifiers
of microphones set up separately. DMR-188 only
offers one AUDIO INPUT (19). This input may be
assigned to any desired video input for recording
(
chapter 8.1).
2) For audio replay, the mono signal of the channel
currently displayed will be available at both RCA
output jacks AUDIO OUTPUT (20). If several
channels are displayed at the same time, the
sound of the last channel shown as a full image
will be replayed.
For DMR-188
, there will be an audio signal at
the jack AUDIO OUTPUT (20) if the channel
assigned is displayed or was the last channel
selected as a full image.
If the units are to be put out of operation
definitively, take them to a local recycling
plant for a disposal which will not be harm-
ful to the environment.
WARNING The power supply unit uses danger-
ous mains voltage. Leave servicing to
skilled personnel only. Inexpert han-
dling or modification of the unit may
result in electric shock.
23

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Monacor DMR-180 SET wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info