13
INSTALLER
Certification, Category and Type: MODEL F-11 E L
E
C Type test certificate 99CN922
C
ategory I
2E+
I
2h
I
3+
I
38/P
Country of destination
BE, FR ES, GB, IE, IT, PT BE, ES, FR, GB, IE, IT, PT NL
T
ype C
12
D
egree of electrical protecction IP-44
S
ymbol Units Model F-11E L
Power an energy consumption
Nominal output power Pn Kw 19,2
Minimun output power Pmin Kw 8,4
Power modulation range Pmin - Pn Kw 8,4-19,2
Nominal energy consumption Qn Kw 22,1
Minimun energy consumption Qmin Kw 9,8
Gas Data
2 H Natural G20 mbar 20
2 E+ Natural G20/G25 mbar 20-25
Connection pressure 3 + Butane G30 mbar 28-30
Propane G31 mbar 37
3 B/P Butane G30 mbar 30
2 H/2 E+
Natural G20
Hi=9,45 Kwh/m
3
m
3
/h 2,34
Gas consumption Natural G25
Hi=8,13 h/m
3
m
3
/h 2,32
3+/(3B/P)
Butane G30
Hi=12,68 Kwh/kg
Kg/h 1,74
Propane G31
Hi=12,87 Kwh/kg
Kg/h 1,72
2 H/2 E+
Natural G20 mbar 12,7
Burner pressure at Natural G25 mbar 16
nominal power
3+/(3B/P)
Butane G30 mbar 27
Propane G31 mbar 33,5
2H/2E+
Natural G20 m
3
/h 23,06
Air Flow needed for Natural G25 m
3
/h 23,37
the combustion
3+/(3B/P)
Butane G30 kg/h 20,19
Propane G31 kg/h 20,27
Water data
Water flow
∆ 50º C l/min 2,-5,5
∆ 25º C l/min 3,7-11
Max operating pressure MPa (bar) 1,3 (13)
Min operating pressure
Max. tp selector MPa (bar) 0,015 (0,15)
Min. tp. selector MPa (bar) 0,025 (0,25)
Combustion products
Flow g/s 15,2
Temperature ºC 160
Electrical Data
Electrical supply V/Hz
220-230V-50 Hz
Maximun absorbed power W 35
Connector dimensions and pipe diameters
Gas inlet Natural 3/4 “
Connections /inner Ø (mm) Butane - Propane 3/4 “
Cold Water Inlet 3/8 “
Hot Water Outlet 1/2 “
Flue outlet (mm) Ø 60-100
8.- TECHNICAL CHARACTERISTICS