646330
6
Zoom out
Zoom in
Vorherige Seite
1/36
Nächste Seite
6
SECTION 1 - USERS INSTRUCTIONS
To unblock a frozen condensate pipe;
1. Follow the routing of the plastic pipe from its exit point on the
appliance, through its route to its termination point.
Locate the frozen blockage. It is likely that the pipe is frozen
at the most exposed point external to the building or where
thereissomeobstructiontoow.Thiscouldbeattheopen
end of the pipe, at a bend or elbow, or where there is a dip in
the pipe in which condensate can collect. The location of the
blockageshouldbeidentiedascloselyaspossiblebefore
taking further action.
2. Apply a hot water bottle, microwaveable heat pack or a warm
damp cloth to the frozen blockage area. Several applications
may have to be made before it fully defrosts. Warm water
can also be poured onto the pipe from a watering can or
similar. DO NOT use boiling water.
3. Caution when using warm water as this may freeze and
cause other localised hazards.
4.
Oncetheblockageisremovedandthecondensatecanow
freely, reset the appliance. (Refer to “To Light the boiler”)
5.
If the appliance fails to ignite, call your Gas Safe Registered Engineer,
orinothercountriesaqualiedandcompetentGasInstaller.
Preventative solutions
During cold weather, set the boiler stat to maximum, (Must return
to original setting once cold spell is over)
Place the heating on continuous and turn the room stat down to 15ºC
overnight. (Return to normal after cold spell).
Escape of gas
Should a gas leak or fault be suspected contact the Gas Supplier
without Delay. TURN OFF ALL GAS SUPPLIES.
Do NOT search for gas leaks with a naked ame.
Cleaning
For normal cleaning simply dust with a dry cloth.
To remove stubborn marks and stains, wipe with a damp cloth
andnishoffwithadrycloth.
DO NOT use abrasive cleaning materials.
Maintenance
The appliance should be serviced at least once a year by a Gas
SafeRegisteredEngineer,orinothercountriesaqualiedand
competent Gas Installer.
Loss of system water pressure
The pressure gauge indicates the central heating system
pressure. If the pressure is seen to fall below the original
installation pressure of 1-2 bar over a period of time then a water
leak may be indicated. In this event re-pressurise the boiler.
If unable to do so or if the pressure continues to drop a Gas
SafeRegisteredEngineer,orinothercountriesaqualiedand
competent Gas Installer should be consulted.
INDICATED BY “F1” (LOW WATER PRESSURE) - THE BOILER
WILL NOT OPERATE IF THE PRESSURE HAS REDUCED TO
LESS THAN 0.3 BAR UNDER THIS CONDITION.
Condensate Drain
Thisapplianceisttedwithasiphoniccondensatetrapsystem
that reduces the risk of the appliance condensate from freezing.
However should the condensate pipe to this appliance freeze,
please follow these instructions:
a. If you do not feel competent to carry out the defrosting
instructions below please call your local Gas Safe Registered
Engineer,orinothercountriesaqualiedandcompetentGas
Installer for assistance.
b.
If you do feel competent to carry out the following instructions
please do so with care when handling hot utensils. Do not attempt
to thaw pipework above ground level.
If this appliance develops a blockage in its condensate pipe, its
condensate will build up to a point where it will make a gurgling
noise prior to locking out an “L2” fault code. If the appliance is
reset it will make a gurgling noise prior to it locking out on a failed
ignition “L2” code.
MECHANICAL 24 HOUR TIMER
PROGRAMMING THE TIMER
1.
Decide what times you would like the timeswitch to switch ON and OFF.
2. Push segments towards the programme ring for an OFF period and
push away from ring for an ON period. The minimum switching
interval is 15 minutes and this can be increased in 15 minute steps.
3. Bring the timeswitch into the correct condition by manually turning
the programme ring clockwise through a 24 hour cycle.
4. Turn the programme ring clockwise until the correct time of day on
the ring lines up with the time indicator.
Note. The segment dial can be turned when the time controller is
operating. In case of power failure, re-adjust the time controller to the
correct time of day, turning the dial in a clockwise direction.
Permanent Override
By rotating the central switch so that the symbol (
1) lines up with the
time indicator ( ) the unit will be permanently ON.
With the symbol (
) lining up with the time indicator ( ) the unit acts as
a timeswitch.
With the symbol (
) lining up with the time indicator ( ) the unit will be
permanently OFF.
1
9
20
2
1
2
2
23
24
1
2
3
4
5
6
7
8
9
10
1
1
1
2
1
3
1
4
15
1
6
17
18
Time & Control
Indicator
24hr Programme Ring
Timer control segments
1 Segment = 15 mins
Push towards programme ring = OFF
Push away from programme ring = ON
OFF segment
ON segment
Permanently ON
Permanently OFF
Timer Control
PRESSURE GAUGE
1
9
20
2
1
2
2
23
24
1
2
3
4
5
6
7
8
9
10
1
1
1
2
1
3
1
4
15
1
6
17
18
0
0
I
preheat
preheat
min
min
max
mode
reset
off
status burner
max
e
6

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

morco-gb24

Suche zurücksetzen

  • Hallo. Wir haben eine GB 24. obwohl wir die Urzeit und alles eingestellt haben springt die Heizung nicht von alleine an morgens. Wir müssen immer das bedienteil an der Wand von Hand betätigen und die Heizung anzustellen. Woran kann das liegen? Und auch die Temperatur im Raum ist so tief da müsste sie doch automatisch anspringen. Danke schonmal Eingereicht am 25-3-2024 07:55

    Antworten Frage melden
  • warum bekomme ich keine deutsche Bedienungs -und Installationsanleitung ? Eingereicht am 23-1-2022 14:31

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Morco GB24 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Morco GB24

Morco GB24 Bedienungsanleitung - Englisch - 8 seiten

Morco GB24 Bedienungsanleitung - Holländisch - 10 seiten

Morco GB24 Bedienungsanleitung - Französisch - 10 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info