646333
32
Zoom out
Zoom in
Vorherige Seite
1/36
Nächste Seite
SECTION 9 - faulT COdES
32
Return Thermistor
Returntemperaturegreaterthanowtemperature.PleasecontactMorco.
9 FAULT CODES
5 Boiler Resets in 15 minutes
1. Turn electrical supply to boiler off and on.
2. If the boiler fails to operate please contact
Morco
(if under warranty) or alternatively a
Gas Safe Registered Engineer if outside of the warranty period. In all other countries
contact a Registered Gas Installer.
False Flame Lockout
Restart the appliance - if the boiler fails to operate then please contact
Morco
(if under
warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty
period. In all other countries contact a Registered Gas Installer.
BCC Activation Fault
Restart the appliance - if the boiler fails to operate then please contact Morco (if under
warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty
period. In all other countries contact a Registered Gas Installer.
DISPLAY CODE ON BOILER
DESCRIPTION
Low Water Pressure
ACTION
Checksystemwaterpressureisbetween1&1.5baronthesystempressure
gauge (G).
To re-pressurise the system see Section 3. If the boiler still fails to operate then please
contact Morco (if under
warranty) or alternatively a Gas Safe Registered Engineer if outside
of the warranty period. In all other countries contact a Registered Gas Installer.
Checksystemwaterpressureisbetween1&1.5baronthesystempressure
gauge (G).
To re-pressurise the system see Section 3. If the boiler fails to operate then please contact
Morco
(if under
warranty) or alternatively a Gas Safe Registered Engineer if outside of the
warranty period. In all other countries contact a Registered Gas Installer.
Flow Temperature Overheat
or No Water Flow
BCC Fault
Flame Loss
Flame Loss
1.Checkothergasappliancesinthehouseareworkingtoconrmasupplyispresentin
the property.
2
.
If other appliances do not work or there are no other appliances, check the gas supply is on
at the meter and/or pre payment meter has credit. If the boiler fails to operate then please
contact Morco (if under warranty) or alternatively a Gas Safe Registered Engineer if outside
of the warranty period.
In all other countries contact a Registered Gas Installer.
1.Checkothergasappliancesinthehouseareworkingtoconrmasupplyispresentin
the property.
2.
If other appliances do not work or there are no other appliances, check the gas supply
is on at the meter and/or pre payment meter has credit. If the boiler fails to operate then
please contact
Morco
(if under warranty) or alternatively a Gas Safe Registered Engineer if
outside of the warranty period.
In all other countries contact a Registered Gas Installer.
Fan Fault
Restart the appliance - if the boiler fails to operate then please contact
Morco
(if under
warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty
period. In all other countries contact a Registered Gas Installer.
Flow Thermistor
Restart the appliance - if the boiler fails to operate then please contact
Morco
(if under
warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty
period. In all other countries contact a Registered Gas Installer.
Return Thermistor
Restart the appliance - if the boiler fails to operate then please contact
Morco
(if under
warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty
period. In all other countries contact a Registered Gas Installer.
Outside Sensor Failure
Restart the appliance - if the boiler fails to operate then please contact
Morco
(if under
warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty
period. In all other countries contact a Registered Gas Installer.
Low Mains Voltage
Contactaqualiedelectricianoryourelectricityprovider.
UnconguredPCB
UnconguredPCB.Pleasecontact
Morco
(if under warranty) or alternatively a Gas Safe
Registered Engineer if outside of the warranty period. In all other countries contact a
Registered Gas Installer.
32

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Morco GB30 SII wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Morco GB30 SII

Morco GB30 SII Bedienungsanleitung - Holländisch - 10 seiten

Morco GB30 SII Bedienungsanleitung - Französisch - 10 seiten