section 3 - tecHnicAL DAtA
Note. Gas consumption is calculated using a
caloric value of 95.65 MJ/m
3
(2569 Btu/ft
3
)
gross or 88.0 MJ/m
3
(2,360 Btu/ft
3
) nett
To obtain the gas consumption at a different
caloric value:
a. For l/s - divide the gross heat input (kW) by
the gross C.V. of the gas (MJ/m
3
)
b. For ft
3
/h - divide the gross heat input (Btu/h)
by the gross C.V. of the gas (Btu/ft
3
)
c. For m
3
/h - multiply l/s by 3.6.
Key to symbols
PMS = Maximum operating pressure of water
C
13
C
33
= A room sealed appliance designed for connection via ducts to a horizontal
or vertical terminal, which admits fresh air to the burner and discharges
theproductsofcombustiontotheoutsidethroughoriceswhich,inthis
case, are concentric. The fan is up stream of the combustion chamber.
I
3P
= An appliance designed for use on 3rd Family gas, Group P only.
* The value is used in the UK Government’s Standard Assessment Procedure (SAP) for energy rating of dwellings. The test data from
whichithasbeencalculatedhavebeencertiedbyanotiedbody.
Morco GB 24 30
Gas supply I
3p
- G31 - 37mbar
Gas Supply Connection 15mm copper compression
Injector Size (mm) 3.75 3.75
Inlet Connection Domestic Hot Water G
1
/2
Outlet Connection Domestic Hot Water G
1
/2
Flow Connection Central Heating G
3
/4
Return Connection Central Heating G
3
/4
Flue Terminal Diameter mm (in) 100 (4)
Average Flue Temp-Mass Flow Rate (DHW) 63
o
C - 11g/s 68
o
C - 13g/s
Maximum Working Pressure (Sealed Systems) bar (lb/in
2
) 2.5 (36.3)
Maximum Domestic Hot Water Inlet Pressure bar (lb/in
2
) 10.0 (145)
Minimum Domestic Hot Water Inlet Pressure* bar (lb/in
2
) 0.8 (11.6) 1.3 (18.9)
Electrical Supply 230 V ~ 50 Hz.
Power Consumption W 146 152
Fuse Rating
External : 3A Internal : T4H HRC L250 V
Water content Central Heating litre (gal) 1.2 (0.26)
Domestic Hot Water litre (gal) 0.5 (0.11)
Packaged Weight kg (lb) 33.8 (74.4) 34.1 (75.2)
Maximum Installation Weight kg (lb) 31 (68.3) 31.2 (68.8)
Boiler Casing Size Height mm (in) 700 (27.5)
Width mm (in) 395 (15.5)
Depth mm (in) 285 (11.2)
Table 1 - General Data
*Required for maximum ow rate. Boiler operates down to 2 l/min DHW delivery
Maximum DHW Input : 24 30
Nett CV kW 24.3 30.4
Btu/h 82,912 103,725
Gross CV kW 26.4 33
Btu/h 90,077 112,596
Gas Consumption m
3
/h 1.00 1.25
ft
3
/h 35.33 44.20
kg/hr 1.83 2.26
Maximum kW 24.2 30.3
DHW Output Btu/h 82,570 103,384
DHW Flow Rate l/min 9.9 12.4
at 35°C temp. rise. gpm 2.2 2.8
DHWSpecicRate l/min 11.5 14.5
gpm 2.5 3.2
Boiler Input : Max. Min.
24 30 24 30
Boiler Input ‘Q’ Nett CV kW 24.3 24.3 8.0 8.0
Btu/h 82,912 82,912 27,296 27,296
Gross CV kW 26.4 26.4 8.7 8.7
Btu/h 90,077 90,077 29,684 29,684
Gas Consumption m
3
/h 1.00 1.25 0.329 0.329
ft
3
/h 35.33 44.20 11.62 11.62
kg/hr 1.83 2.26 0.58 0.58
Boiler Output :
Non Condensing kW 24.2 24.2 8.00 8.00
70
o
C Mean Water temp. Btu/h 82,570 82,570 27,296 27,296
Condensing kW 25.6 25.6 8.5 8.5
40
o
C Mean Water temp. Btu/h 87,347 87,347 29,002 29,002
Seasonalefciency*SEDBUK2005 91% 91.1%
Seasonalefciency*SEDBUK2009 89% 89%
NOxClassication CLASS5
Table 2 - Performance Data - Central Heating
Table 3 - Performance Data - Domestic Hot Water
10

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Morco GB30 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Morco GB30

Morco GB30 Bedienungsanleitung - Englisch - 8 seiten

Morco GB30 Bedienungsanleitung - Holländisch - 10 seiten

Morco GB30 Bedienungsanleitung - Französisch - 10 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info