1.3 Flue Connection
The stove is supplied from the factory with a ue collar tted to the top plate and a round
blanking plate blocking o the rear ue exit (behind the rear shield plate).
Use a 24 MSG black or blue chimney connector or listed double wall chimney connector. Re-
fer to local codes and the chimney manufacturer’s instructions for precautions required for
passing a chimney through a combustible wall or ceiling. Remember to secure the chimney
connector with a minimum of three screws to the product and to each adjoining section.
The collar can be tted to the rear outlet. Simply knock out the round panel on the rear heat
shield plate to reveal the cast iron plate. Untwist the blanking plate and the ue collar and
swap their positions. Re-secure by pushing down and tighten the enclosed screws.
Position the stove and connect to the ue system.
Wear gloves and protective eyewear when drilling, cutting or joining sections of chim-
ney connector.
1.4 Connection to the existing chimney
A chimney connector is the double-wall or single-wall pipe that connects the stove to the chim-
ney. The chimney itself is the masonry or prefabricated structure that encloses the ue. Chim-
ney connectors are used only to connect the stove to the chimney.
Double-wall connectors must be tested and listed for use with solid-fuel burning applianc-
es. Single-wall connectors should be made of 24 gauge or heavier gauge steel. Do not use
galvanized connector; it cannot withstand the high-temperatures that smoke and exhaust
gases can reach, and may release toxic furnes under high heat. The connector must be 6
inches (150mm) in diameter.
If possible, do not pass the chimney connector through a combustible wall or ceiling.
If passage through a combustible wall is unavoidable, refer to the sections on Wall Pass-
Throughs. Do not pass the connector through an attic, a closet or similar concealed space
when installing the chimney connectors.
It is important to keep the ue gases moving smoothly in the right direction. Do not vent
into a large void at this location; rather form one continuous section all the way up. Use mild
bends (e.g. 45º vs. 90º) rather than sharp angles where a change of direction is required. All
parts of the venting must be accessible for cleaning purposes.
In horizontal runs of chimney, maintain a distance of 18 inches from the ceiling. Keep it as
short and direct as possible, with no more than two 90 degree turns. Slope horizontal runs
of connector upward 1/4 inch per foot (20 mm per metre) going from the stove toward the
chimney. The recommended maximum length of a horizontal run is 3 feet (1 metre), and the
total length should be no longer than 8 feet (2.5 metres).
Information on assembling and installing connectors is provided by the manufacturer’s in-
structions exactly as you assemble the connector and attach it to the stove and chimney.
Be sure the installed stove and chimney connector are correct distances from near by
combustible materials. See the clearance paragraph page 8.
6

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Morso 3400 series wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Morso 3400 series

Morso 3400 series Bedienungsanleitung und Installationsanweisung - Deutsch - 20 seiten

Morso 3400 series Bedienungsanleitung und Installationsanweisung - Holländisch, Französisch - 32 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info