INSTRUCTION MANUAL INPUT/OUTPUT MODULE EA 36.32 KNX HUGO MÜLLER GMBH & CO KG, STURMBÜHLSTR. 145-149, 78054 VS-SCHWENNINGEN
SAFETY INSTRUCTIONS AND BASICS
EA 36.32 knx
Service:
Hugo Müller GmbH & Co KG
Sturmbühlstraße 145-149
D-78054 VS-Schwenningen
Germany
+49 7720 80836
www.hugo-mueller.de
Technical data
Safety instructions / Intended use
Power supply:
Bus current:
24 V DC (via KNX bus voltage)
< 10 mA
CAUTION! DANGER OF FIRE AND ELECTRIC SHOCK!
!!!Installation and assembly of electrical equipment must be carried out only by a skilled person!!!
Bus system:
KNX-TP/S
Connect only to suitable supply voltage [KNX bus voltage (nominal voltage 29V)].
Warranty void if housing opened by unauthorized person!
The electronic circuit is protected against a wide range of external influences. Incorrect operating may occur if external in fluences
exceed certain limits!
Installation and assembly of electrical equipment must be in accordance with national building, electrical and safety codes!
Defective devices / sensors have to be put out of service immediately!
Observe the regulations and instructions in the ZVEI/ZVEH handbook (building system technology). Especially the professional
installation of the bus lines and the professional installation and start -up of KNX devices must be observed!
The device fits for the particular use of the following tasks: monitoring of the air quality in building systems technology (schools,
offices, hotels, conference venue etc.), data transfer and regulation via bus system.
The device is intended for use in accordance with the defined technical data.
Operate the device exclusively in a dry room!
The device is not qualified for security relevant tasks such as emergency doors, fire protection equipment, fermenting cellar s etc.
Inputs:
3x binary Inputs (INPUT 1 / 2 / 3)
Input 2/3 can also be used as Input for external
temperature probes (PT1000 / Müller TF06). This
function requires use of both Inputs (2 and 3).
Outputs:
2x outputs (OUTPUT 1, OUTPUT 2)
- Can be configured as LED-driver (< 3 mA)
- Can be configured as Open-collector output
with the following specifications:
ext. supply voltage (U
max
) = 50 V DC
max. switching current (I
max
) = 80 mA
max. switching power (P
max
) = 200 mW
Voltage level on low signal = 0,5 V DC
Permitted ambient temperature:
-5°+45 °C
Housing:
self-extinguishing thermoplastic
Mounting:
Flush-mount (hollow-wall box)
Type of connection:
KNX bus terminal
Type of protection:
IP 20 to DIN EN 60529
Class of protection:
III when installed according to regulations
Inappropriate use / disposal
Input / Output Description (examples)
The device is not intended for use of unauthorized constructional alterations , repairs
and security relevant tasks.
The device is not intended for use in outdoor areas or wet rooms.
The device is not qualified for security relevant tasks. The intended use of the device is
only for comfort functions in home automation systems.
The inappropriate use of the device can cause damage to property and persons .
The device has to be disposed in an environmentally friendly manner according to the
current electrical codes!
Assembly
Disconnect device from power supply for wiring and installation
purposes! Check power supply is disconnected!
Attention! You have to check and consider the safety instructions above!
This device is suitable for mounting in a flush-mounting box.
Ensure that no dust gets inside of the device.
STEP 1: Connect the required inputs / outputs according to the schematics diagram.
STEP 2: Connect the KNX bus cable according to the color-coded connectors.
STEP 3: After wiring, press the programming buttonto set the device into
programming mode for addressing & configuration via ETS application.
STEP 4: Place / install device into the hollow-wall box.
Installation note: Make sure that no wires are pinched or squeezed when placing the device into the hollow-wall box.
Inputs configured as binary inputs
Outputs configured as LED drivers
Input 1 = binary input, Input 2/3 = temperature probe input
Outputs configured asopen-collector
Uext.:
Umax= 50 V DC
Imax = 80 mA
Pmax = 200 mW
2

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Muller EA 36.32 knx wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info