ANNEX: PROTECTIONS AND FUNCTIONS
1. Frost protection function:
In cooling or dehumidifying mode, if the temperature of the copper tube is too low, the machine will automatically
work in the defrost state; If the temperature of the copper pipe rises to a certain temperature, it can automatically
return to normal operation.
2. Protection function against water overflow:
When the water in the water tray exceeds the warning level, the machine will automatically sound an alarm and
the 'Water Full' indicator will flash. At this point, it is necessary to connect the machine or remove the water plug to
empty the water. After draining the water, the machine will automatically return to the working mode.
3. Compressor funciton protection
To increase the life of the compressor, it has a start protection function with a delay of 3 minutes after turning off
the compressor.