HI-LINE RC & HI-LINE RC Heater/Cooler
10.0 Technical Data
Model Fan Speed
Heat Output (watts)
Temperature Difference (°C)
Heat Output (Btu/h)
Temperature Difference (°F)
2737 3101 3468 3836 4207 4579
3457 3917 4380 4845 5314 5784
3917 4436 4959 5485 6014 6545
1941 2199 2459 2721 2983 3248
2197 2489 2783 3079 3376 3675
2913 3300 3690 4082 4477 4873
1271 1440 1610 1781 1953 2126
1546 1752 1959 2167 2376 2587
1990 2255 2521 2789 3059 3330
734 831 930 1029 1128 1228
1020 1156 1292 1430 1568 1707
1344 1522 1702 1883 2065 2248
Normal
Medium
Boost
Normal
Medium
Boost
Normal
Medium
Boost
Normal
Medium
Boost
20-14
15-10
10-6
7-4
9339 10581 11831 13089 14354 15625
11796 13365 14944 16533 18130 19735
13363 15136 16920 18715 20518 22331
6625 7504 8391 9282 10179 11081
7495 8492 9495 10504 11519 12539
9939 11260 12591 13929 15275 16628
4336 4912 5493 6076 6664 7254
5276 5977 6684 7394 8109 8827
6971 7694 8603 9517 10437 11361
2504 2837 3172 3509 3848 4189
3481 3944 4410 4879 5350 5824
4584 5194 5807 6424 7045 7669
40° 45° 50° 55° 60° 65° 72° 81° 90° 99° 108° 117°
Cooling Performance Data
Noise Levels
Model Fan Speed
Cooling Performance (watts)
Air-Mean Water Temperature Difference (°C)
Cooling Performance (Btu/h)
Air-Mean Water Temperature Difference (°F)
1256 1034 1922 1291 2676 1421
1510 1241 2312 1597 3220 1759
1601 1363 2449 1770 3408 1879
886 761 1355 1002 1886 1091
958 815 1466 1058 2041 1123
1276 1093 1953 1434 2719 1549
578 490 884 635 1230 668
646 545 988 704 1375 736
780 638 1194 867 1662 1098
318 274 487 362 678 396
473 405 725 531 1009 574
574 459 878 623 1222 790
Normal
Medium
Boost
Normal
Medium
Boost
Normal
Medium
Boost
Normal
Medium
Boost
20-14
15-10
10-6
7-4
4284 3530 6557 4405 9131 4849
5153 4234 7887 5449 10985 6002
5462 4650 8354 6039 11628 6412
3022 2598 4624 3420 6435 3721
3268 2781 5001 3609 6965 3833
4354 3730 6664 4892 9276 5284
1971 1671 3016 2166 4195 2279
2202 1861 3370 2404 4690 2512
2662 2178 4074 2957 5671 3748
1085 936 1663 1237 2313 1352
1614 1383 2473 1813 3443 1959
1957 1567 2995 2126 4170 2695
Tot. Sens. Tot. Sens. Tot. Sens.
15° 20° 25° 27° 36° 45°
Tot. Sens. Tot. Sens. Tot. Sens.
Heat outputs tested in accordance with
BS 4856 Part 1.
Flow rate 340 ltr/h (75 gal/h).
Flow Rate Correction Factors:
455 ltr/h (100 gal/h) multiply by 1.06.
227 ltr/h (50 gal/h) multiply by 0.96.
113 ltr/h (25 gal/h) multiply by 0.85.
Noise levels tested in accordance with EN 23741.
Test Pressure 20bar (2 MPa)
Water connections 15mm
Maximum working pressure 10bar (1MPa)
Electrical supply 230V - 50Hz
Cooling performance tested in accordance with BS 4856 Part 2. Flow rate 340 ltr/h. Relative humidity 50%.
Model
Sound Pressures at 2.5m (dBA)
20-14 33.3 38.7 45.4
15-10 28.8 35.4 45.6
10-6 23.5 30.8 37.2
7-4 23.4 32.5 43.3
Normal Medium Boost
Weight, Water Content and Motor Power
Model
Motor
Power (W)
Water
Content (l)
Unpacked
Weight (kg)
20-14 80 0.30 7.4
15-10 62 0.32 8.9
10-6 35 0.56 11.3
7-4 35 0.77 14.7
Heating Performance Data
Approximate Hydraulic Resistance through Fan Convectors
Litres/h
7-4
1084
798
350
134
10-6
1240
657
327
105
15 -10
1500
905
450
157
20 -14
1774
1140
565
221
7-4
9.4
7.7
3.5
1.4
10-6
12.12
6.42
3.25
1.1
15 -10
14.7
8.9
4.37
1.57
20 -14
17.42
11.2
5.5
2.1
455
340
227
113
mm wg
kPa
23673 HiLine manual UK 27/06/2011 09:12 Page 9
8

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Myson HI-LINE RC 10-6 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info