19
Intensive setting:
Maximum power is obtained at the
intensive setting. It is only required for short
intervals.
❑ Keep pressing the + button until a
ç
appears in the display.
❑ If the intensive setting is not cancelled by
hand, the fan will automatically switch
back to step } after 10 minutes.
Fan follow-on:
❑ Press the button.
The fan runs for 10 minutes at the
selected setting and
! is displayed.
Then the fan automatically switches off.
Lighting:
❑ Briefly press the
a button to switch the
light on and off.
❑ The light can be switched on at any
time, even though the fan is switched off.
❑ Adjusting the brightness:
Hold down the
a button until the
desired brightness is obtained.
Switching on the light automatically, e.g.
via a timer:
❑ Fan and light must be switched off.
Switching on:
Simultaneously press the – and
!
buttons.
❑ After approx. 3 seconds the light
switches on to acknowledge the setting.
Switching off:
Repeat the process with the light switched
on.
❑ After approx. 3 seconds the light
switches off to acknowledge the setting.
Operating procedure
Acoustic signal:
❑ When a button is pressed, this is verified
by an acoustic signal.
Switching off the acoustic signal:
❑ Simultaneously press buttons 0 and +
until a signal is emitted after approx. 3
seconds.
Switching on the acoustic signal:
❑ Repeat the process.
Switching the fan ON
❑ Press the + button.
Setting the required fan speed:
❑ Press the + button.
The fan speed is increased by one step.
❑ Press the – button.
The fan speed is reduced by one step.
Switching the fan OFF:
❑ Press the 0 button.
The displayed
{ goes out shortly
afterwards.
Or:
❑ Keep pressing the – button until the fan
switches off.
The displayed
{ goes out shortly
afterwards.
ṇ The most effective method of removing
vapours produced during cooking is to:
❑ Switch the ventilator ON
as soon as you begin cooking.
❑ Switch the ventilator OFF
a few minutes after you have finished
cooking.
Light
Fan OFF
Reduce fan
speed
Fan ON and
increase speed
Display for fan setting
Fan follow-on
Saturation indicator