12 | Product details
Determined use
The product must only be used for controlling heating
systems.
Any other use is considered improper. Any damage that may
result is excluded from liability.
Installation, commissioning and maintenance
Installation, commissioning and maintenance must only be
carried out by a suitably qualified engineer.
Only genuine spare parts must be installed.
Electrical work
Electrical work must only be carried out by qualified
electricians.
Before carrying out electrical work:
Isolate all poles of the mains voltage and secure against
reconnection.
Using suitable means, test the power supply is
disconnected.
▶The product requires different voltages.
Do not connect the low voltage side to the mains voltage or
vice versa.
Also observe connection diagrams of other system
components.
Handover to the end user
When handing over the heating system, explain the operating
conditions to the user.
Explain how to operate the heating system, with particular
emphasis on all safety-related actions.
Explain that conversions or maintenance must only be
carried out by a suitably qualified engineer.
Point out the need for inspections and maintenance for
safe and environmentally friendly operation.
The installation and operating instructions must be given to
the end user for safekeeping.
Damage caused by frost
The system can freeze if it is switched off:
Observe the notices regarding frost protection.
Due to the additional functions, e.g. DHW heating or anti-
seizing protection, the system should always be left on.
Correct any faults immediately.
2 Product details
The module is used to activate
A heating circuit with a heating pump; with or without
mixing valve actuator
A cylinder primary circuit with separate cylinder
primary pump and DHW circulation pump (DHW
circulation pump optional).
The module is used to record
The flow temperature in the assigned heating circuit or
the temperature of the DHW cylinder
The temperature at a low loss header (optional)
7716 192 614
The control signal from a temperature switch in the
assigned heating circuit (optional for a heating circuit
without mixer).
In the following, a heating circuit, constant
heating circuit is generally referred to simply
as a heating circuit.
Function
Max. 4 heating circuits with mixer 
without mixer
1)
1) Max. one heating circuit without mixer recommended

Multiple heating circuit
hydraulic connection
low loss header
Buffer cylinder
2)
2) Not shown in the system schematics.

Flow temperature sensor – system (to T0)
(e.g. on low-loss header)

Possible heating circuit
functions
Heating 
Constant heating
circuit
3)
3) For constant flow temperature, e.g. swimming pool or hot
air heating.
Cooling
External signal for heat requirements (to MD1),
heating pump on/off for a constant heating circuit
Cylinder primary circuit 1 or 2
4)
4) DHW cylinder downstream of low loss header.
DHW circulation pump
Table 2 Functions of module in combination with heat pump
( ) or other heat source ( )
12

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Nefit MM100 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info