24
7 8 9
10 11 12
After cleaning process the machine switches
to maximum energy saving mode.
Remove cleaning key and insert two cleaning
tablets.
Daily Cleaning
Place empty container back into the
refrigerator and guide the suction tube with
temperature sensor and level sensor into the
container. Press any button.
After cleaning, carefully wipe milk suction
tube with temperature sensor and level sen-
sor, using only single-use disposable tissue or
paper towel. Usage of non-disposable tissue
or sponge can lead to bacterial contamina-
tion of the milk.
~28 min.
CAUTION
Risk of corrosive injury
Direct contact with cleaning
detergent with eyes may cause
injury.
Clean your hands after han-
dling cleaning tablets.
Wear gloves/goggles.
NOTICE
Cleaning solutions
The use of inappropriate cleaning solu-
tions may damage parts of the machine
or may lead to improper cleaning
efficiency.
Use only Thermoplan milk cleaning tab-
lets to perform the automatic cleaning.
Remove cleaning key
Insert cleaning tablets
Cleaning in progress: 28:15
Please wait!
Insert cleaning key
Cleaning procedure starts auto-
matically after the cleaning key is
inserted.
To restart machine from maximum
energy saving mode, ►see page 16.
Empty remaining water, clean milk container
with potable water and place it back into the