28
Milk parameter: Milk foam settings Milk parameter: Refrigerator settings Cup heater
Menu Settings
- Milk parameters
• Milk foam settings:
- Hot foam
- Cold foam
• Refrigerator settings
- Cup heater
Press rinse button for 3 sec.
USER MENU
MILK PARAMETERS
Select menu “MILK PARAMETERS”
Enter
MILK PARAMETERS
HOT FOAM = 0 %
Select “HOT FOAM = 0 %”
Enter
HOT FOAM = 0 %
[ -10.0 .. ◄ 0 % ► .. 10.0]
Increase or decrease the amount of
air in the hot milk foam if required.
Range: -10 % to 10 % from default.
Enter
MILK PARAMETERS
HOT FOAM = 3 %
Repeat this procedure for
COLD FOAM if necessary.
Exit menu
Press rinse button for 3 sec.
USER MENU
MILK PARAMETERS
Select menu “MILK PARAMETERS”
Enter
MILK PARAMETERS
Cooling temperature = 5.0 °C
Select
“Cooling temperature = 5.0 °C”
Enter
Cooling temperature = 5.0 °C
[ 4.0 .. ◄ 5.0 °C ► .. 8.0]
Increase or decrease the cooling
temperature if required or set to
DEFAULT (recommended).
Enter
Exit menu
Press rinse button for 3 sec.
USER MENU
MACHINE PARAMETERS
Select menu “MACHINE PARAM-
ETERS”
Enter
MACHINE PARAMETERS
Cup heater = On
Select
“Cup heater = On”
Enter
Cup heater = on
◄ On ►
Select “On” or “Off”
Enter
Exit menu
Milk foam settings
To change the uidity
of the milk foam, simply
change the % of air in the
milk foam as shown on this
page:
• -10%: more liquid foam
• 0%: installation setting
• +10%: more solid foam