NIKON VISION CO., L TD.
Customer Service Department
3-25, Futaba 1-chome, Shinagawa-ku, T okyo 142-0043, Japan
T el: +81-3-3788-7699 Fax: +81-3-3788-7698
Printed in China (197K)/1E
CAUTIONS BEFORE USE
Please observe the following guidelines strictly so you can use the equipment properly
and avoid potentially hazardous problems. Befor e using this product, r ead thoroughly the
“SAFETY AND OPERA TION PRECAUTIONS” and instructions on correct usage
accompanying the product. Keep this manual within reach for easy r eference.
WARNING
This indication alerts you to the fact that any improper use ignoring the contents
described herein can result in potential death or serious injury .
CAUTION
This indication alerts you to the fact that any improper use ignoring the contents
described herein can result in potential injury or material loss.
SAFETY AND OPERA TION PRECAUTIONS
Warning
•
Never look directly at the laser beam or directly at the sun when using the Nikon
Callaway id TECH.
• DonotdepressthePOWERbuttonwhilelookingintotheopticsfromtheobjectiveside.
• Donotaimattheeye.
• Donotoperatetheunitwithotheradditionalopticalelements,suchaslensesor
binoculars. Using an optical instrument together with the Nikon Callaway id TECH
increases the danger of damaging the eyes.
• DonotdisassembletheNikonCallawayidTECH.Aproductthathasbeendisassembled
is not guaranteed by the manufacturer .
•
WhentheNikonCallawayidTECH’ sbodycoverisdamaged,orifitemitsastrange
sound due to dropping or for some other cause, immediately remove the
battery and stop using.
Cautions
• WhennotusingtheNikonCallawayidTECH,donotpushthePOWERbutton.
• DonotleavetheNikonCallawayidTECHwithinthereachofsmallchildren.
• Rain,water ,sandandmudshouldberemovedfromtherangefinderbodysurfaceassoon
as possible, using a soft, clean, dry cloth.
• AlthoughtheNikonCallawayidTECHiswaterproof,itisnotdesignedforuse
underwater .
• DonotswingtheNikonCallawayidTECHbyitsstrap.Itmayhitsomeoneandcause
injury .
• DonotleavetheNikonCallawayidTECHinanunstableplace,asitmayfallandcause
injury , or damage the equipment.
• DonotlookthroughtheNikonCallawayidTECHwhilewalking.Y oumaywalkinto
something and get hurt.
• DonotleavetheNikonCallawayidTECHinacaronahotorsunnyday ,ornearheat-
generating equipment. This may damage or negatively affect it.
• DonotleavetheNikonCallawayidTECHindirectsunlight.Ultravioletraysand
excessive heat may negatively affect or even damage the unit.
• WhentheNikonCallawayidTECHisexposedtosuddenchangesintemperature,water
condensation may occur on lens surfaces. Do not use the product until the condensation
has evaporated.
• Donotusealcoholforcleaningthemainbody .
• Donotleavethepolyethylenebagusedforpackagingwithinthereachofsmallchildren.
• Becarefulthatsmallchildrendonotinadvertentlyswallowtheeyecup.Ifitdoeshappen,
consult a doctor immediately .
• Ifyouusetherubbereyecupforalongperiodoftime,youmaysufferskininflammation.
If you develop any symptoms, consult a doctor immediately .
• WhencarryingtheNikonCallawayidTECH,storeitinthesoftcase.
• IfyourNikonCallawayidTECHshouldfailtooperatecorrectly ,discontinueuse
immediately and consult the T roubleshooting T able. If you are unable to fix the problem,
contact your local dealer for instructions on where to send it for repair .
CARE AND MAINTENANCE
Lenses
• Whenremovingdustonthelenssurface,useasoftoil-freebrush.
• Whenremovingstainsorsmudgeslikefingerprintsfromthelenssurface,wipethelenses
very gently with a soft clean cotton cloth or quality oil-free lens tissue.
Use a small quantity of pure alcohol (not denatured) to wipe stubborn smudges. Do not
use velvet cloth or ordinary tissue, as it may scratch the lens surface. Once the cloth has
been used for cleaning the body , it should not be used again for the lens surface.
Main body
• Cleanthebodysurfacewithasoft,cleanclothandadrycloth.Donotusebenzene,
thinner , or other organic agents because they may cause discolouration or rubber
degeneration.
Storage
• Watercondensationormouldmayoccuronthelenssurfacebecauseofhighhumidity .
Therefore, stor e the Nikon Callaway id TECH in a cool, dry place.
After use on a rainy day or at night, thoroughly dry it at room temperatur e, then store in a
cool, dry place.
NOTES ON LITHIUM BA TTER Y
If handled incorrectly , batteries may rupture and leak, corroding equipment and staining
clothing. Be sure to observe the following:
• Installbatterieswiththe+and–polespositionedcorrectly .
• Batteriesshouldberemovedwhenexhaustedorduringextendedperiodsofnon-use.
• Alwaysusethesamebrandofbattery .
• Ifbatteryfluidcontactseyesorskin,rinsewellwithwater .Ifswallowed,consultadoctor
immediately .
• Donotshort-circuitbatterychamberterminals.
• Donotcarrybatteriestogetherwithkeysorcoinsinapocketorbag.Thismayoverheat
and short-circuit batteries.
• Donotputbatteriesinfireorwater .Neverdisassemblebatteries.
• Donotchargebatteries.
• Donotsubjectstoredbatteriestoextremesintemperatur e.
• Donotsubjectbatteriestostrongvibrationsorshock.
Key Features
Body .............................................x1
Soft case ......................................x1
Neckstrap ..................................... x1
Lithium battery (CR2) ....................x1
Composition
• Li ne ar di st an ce me as ur em en t r an ge : 10-500meters/11-550yards/33-999feet
• Anglemeasurementrange:±89°
• Distancemeasurementdisplaystep:
[Internal Display]:
(Linear Distance)
0.5 meter/yard, 1 foot
(measurement distance is less than 100 meters/yar ds/feet)
1.0 meter/yard, 1 foot
(measurement distance is 100 meters/yar ds/feet or farther)
(Horizontal Distance/Height)
0.2 meter/yard, 0.5 foot
(measurement distance is less than 100 meters/yar ds/feet)
1.0 meter/yard, 1 foot
(measurement distance is 100 meters/yar ds/feet or farther)
(Angle)
0.1°(-10°ー 10°)
1.0°( ≦ -10°,10° ≦ )
[External Display]:
(Linear distance) 0.5 meter/yard, 1 foot
(Horizontal Distance/Height) 0.2 meter/yard, 0.5 foot
(Angle) 0.1°
• Easy-to-aim6xopticalobservationsystem
• Quantifiesthehorizontaldistancetothetargetanditsheightinr elationtothe
rangefinder's level by measuring linear distance and angle.
• Measuretheverticalseparation(heightbetweentwopoints).
• Theresultsar edisplayedonbothaninternalandanexter nalLCDpanel.The
external LCD panel shows all results simultaneously .
• MeasureanddisplayinFirstT ar getPriority .
• W aterproofdesign(NOTdesignedforunderwaterusage)
• Invisible/EyesafeIECClass1MLaser
• 30-secondresultsdisplay
• Compact,lightweight,ergonomicdesign
• Automaticshut-off(afterappr ox.30sec.unattended)
• Defaultto“LastUse”settings
• 20-secondcontinuousmeasuringfunction
The Nikon Callaway id TECH emits invisible, eyesafe, infrared energy pulses
that reflect of f the selected target back to its optical receiver . Sophisticated
precision charge cir cuitry is used to instantaneously calculate distances, by
measuring the time it takes for each pulse to travel from the rangefinder to the
target and back. Laser reflectivity and measur ement results may vary according
to climatic and environmental conditions, the colour , surface finish, size, shape
and other characteristics of the target.
The following factors ensure best range and accuracy:
• Nighttimeuse
• Cloudyweather
• Bright-colouredtar gets
• T argetswithhighlyr eflectivesurfaces
• T argetswithshinyexteriors
• Large-sizetar gets
• Shootingtargetsfacingat90degr ees
Measurement may result in inaccuracy or failure in the following cases:
• Slenderorsmalltarget
• T argethasdif fusingreflectivesurface
• T argetdoesnotr eflectthelaserbeam(glass,amirror ,etc.)
• Blacktarget
• T argethasvaringdepths
• Insnow ,rainorfog
• T argetmeasur edthroughglass
• Reflectivesurfacemeasuredfr omdiagonaldirection
• Movingtarget
• Obstaclemovinginfrontofthetar get
• Whentargetingthesurfaceofwater
Nomenclature
1
Monocularobjectivelens/
Laser emission aperture
2
Laser detector aperture
3
External LCD
4
MODEbutton
5
POWERbutton
6
6x monocular eyepiece
7
Eyecup/diopter adjustment ring
8
Diopter index
9
Strap eyelet
!p
Battery chamber cover
!q
Battery chamber cover “Open/
Close” indication
!w
Product number/explanatory label
!e
Laser warning label
Internal Display
1. 『 』- T a rg e t fo c us i ng / La s er ir r ad i at e sy s te m
『
』-
Aim at the target. P osition the target
at the center of the reticle.
『
』- Appears while the laser is being used
for a measurement. (Remains present during
single measurement.Blinks during continuous
measurements.)
Warning: Do not look into the objective lenses
when this mark is shown.
2. 『
』: Distance/measurement status display
Digitally indicates measured distance in meters/yards/feet and angles in
degrees. Also indicates measuring status such as “Measurement in
progress”, “Measurement unsuccessful” or “Unable to measure.”
<Examples of measurement results>
(Distance)
Display of results: ( ≧ 100m/yards/feet) e.g. 234 meters =
『
』
Display of results: ( < 100m/yards) e.g. 76.5 yards = 『
』
Display of results: ( < 100 feet) e.g. 82 feet = 『
』
(Angle)
Display of results: ( ≦ -10˚ and ≧ 10˚ ) e.g. 36˚=『
』
e.g. -29˚=『
』
Display of results: (-10˚< and < 10˚ ) e.g. 3.5˚=『
』
e.g. -7.0˚ =『
』
『
』- Now measuring
『
』- Failure to measure or unable to measure distance
3. 『
』
Display Units
『
』Indicates distance being measured in meters.
『
』Indicates distance being measured in yards.
[No unit displayed] Indicates distance is measured in feet.
4. 『
』- Indicates batter y condition. (See " Changing Batteries" )
5 . 『
』Display Modes
(See “Measurement and Display” for operations and display examples.)
Linear distance mode
『
』Calculates linear distance to your target and displays the results.
Horizontal distance mode
『
』 Calculates horizontal distance to your target by measuring
the linear distance and angle, and displays the results.
Height mode
『
』 Measures your target's height from the horizontal level, and
displays the results.
Vertical separation (height between two points) mode
『
』 Uses the linear distance and angle data of two points to
calculate and display the vertical separation (height
between the two points.)
Angle mode
『
』 Measures the angle of your target from the horizontal level
and displays the results.
Although the LCD was produced using the most advanced technology, it is
impossible to eliminate dust completely . When using this product, the LCD is
magnified by high magnification of the eyepiece lens and dust may a ppear as
a defect. It will not, however , affect measurement accurac y .
Operational Summary
Caution—use of controls or adjustments or performance of
procedures other than those specified herein may result in
hazardous radiation exposure
1. Install a battery in the battery chamber . (See Changing
Batteries)
2. Rubber eyepiece cup
Eyeglass wearer: Collapse the eyepiece cups.
Non-eyeglass wearer: Do not collapse the eyepiece cups.
3. Diopter adjustment
Adjust diopter to obtain a c lear image in the LCD.
First, rotate the diopter adjustment ring counterc lockwise until it comes to a
complete stop. Next, turn on the power to activate the LCD when you look
through the Nikon Callaway id TECH. Rotate the diopter adjustment ring
clockwise until the display comes into focus.
If the diopter is not adjusted to correspond to your eyesight, you may not be
able to clearly focus your subject.
4. Measuring
Note: See separa te “Measurement and Display” sheet for external LCD panel.
Note: Depressing and holding do wn the POWER button causes all symbols to be
displayed in the internal LCD panel. After you remove your finger from the
POWER button, the last-used setting is displayed. (If you briefly press the
POWER button then remove your finger , the LCD panel may display the last-
used setting without displaying all of the symbols. This is not a malfunction
or other problem.)
Before measuring, be sure to confirm settings, such as unit, measurement/display
mode and priority mode.
◎: See the relevant mode section in this manual for setting.
Changing Batteries
T ype of battery: 3V CR2 lithium battery
Battery condition indicators
: Ba ttery has enough charge for use.
: Ba ttery charge is getting low.
flashing: Batter y charge is low and batter y
should be replaced.
disappears: Battery is exhausted and should
be replaced.
flashing in the LCD indicates that the batter y should be replaced.
1 Open the battery chamber cover
Using the ball of the thumb or a coin in the recessed part of the battery
chamber cover , rotate the cover following the Open/Close arrow indica tor . It
may not open easily due to its rubber packing for water resistance.
2 Replace the old battery with a new one
Install new battery with the [+] and [-] correctly positioned follo wing the
“Battery installa tion” indication seal in the batter y chamber . (Insert battery
positioning the [+] pole towards the inside of the chamber .) [The Nikon
Callaway id TECH will not operate if the battery is installed incorrectly .]
3 Close the battery chamber cover
Align the Open/Close indicator with the white dot and insert the batter y
chamber cover . Using the ball of the thumb or a coin, turn the cover in the
opposite direction to the arrow indicator . It may not close easily due to the
rubber packing for water resistance, but continue to turn it all the way until
it stops. Confirm that the cover is securely closed.
Battery life
Continuous operation:
Approx. 10,000 times (at 20°C)
T arget focusing, measurement, and automatic power off are included in a
single cyc le. This figure may differ according to temperature, and other
factors such as target shape, colour , etc.
* The Nikon Callaway id TECH come with a 3V CR2 lithium battery. However , due to
natural electric discharge, the life of the battery will likely be shorter than that noted
above.
Replace batter y if the Nikon Callaway id TECH is ever submerged in water or if water
enters in the battery chamber .
Specifications
Laser Rangefinder
Thank you for purchasing the Nikon Callaway id TECH.
This high-spec laser rangefinder features a new angle measurement function in
addition to the existing linear distance measurement function for enhanced
enjoyment of sports and other outdoor applications. (The Nikon Callaway id
TECH is also able to measure the horizontal distance to a target and its height.)
Please observe the following guidelines strictly so you can use the equipment
properly and avoid potentially hazardous problems. Before using this product,
read thoroughly the “SAFETY PRECAUTIONS” and instructions on correct usage
accompanying the product.
Use of controls or adjustments or performance of pr ocedures
other than those specified herein may r esult in hazardous
radiation exposure.
Keep this manual within reach for easy r eference.
• Specificationsanddesignaresubjecttochangewithoutnotice.
• Noreproductioninanyformofthismanual, inwholeorinpart(exceptforbrief
quotation in critical articles or reviews), may be made without written
authorization from NIKON VISION CO., L TD.
Instruction Manual
Callaway id TECH
POWER
Set FULL/Limited
measurement mode
LCD is illuminated
Set your desired modes
◎
Align the reticle
with the target
POWER
appears
Results are converted to the
mode set and displayed.
MODE
Indication
remains
illuminated for
30 sec.
30 seconds pass without operation *
Power off: LCD indications disappear
Measure again
Fail to measure
Cannot measure
Successfully
measured
For continuous distance
and angle measurement
(up to 20 seconds), keep
button depressed.
※
or
☆
☆【Continuous measurement mode 】
Keeping the POWER button depressed allows you to perform
continuous measurement for 20 seconds.
Blinks while performing measurements.
When measuring a pin at a golf course, for example, use Continuous
measurement mode for easy measurement. With no objects between you
and the pin, the smallest number is the distance to your targeted pin.
※ See the “Measurement and Display” sheet for details regarding the
operations and results display of the various modes.“
* P ower turns off 30 seconds after the last operation.
5. Selecting display unit (Factory default setting is yard.)
Meter [ ]
Y ard
[ ]
Feet [ ]
1. Confirm the LCD panel is on.
2. Press and hold the
button for approx. two seconds.
3. When display unit has switched, release the
button.
4. Repeat steps 2 and 3 until your desired mode is displayed.
5. When you ha ve completed setting, results will be converted and displayed
in the your selected measurement unit.
6. Switching measurement/display modes (F actory default setting is
linear distance measurement mode)
Linear Distance [ ]
Horizontal Distance [ ]
Angle [ ]
Height [
]
Vertical Separation
between 2 points point
[ ]
By pressing the MODE button, modes will change in
the order indicated above.
The angles and heights of two points are displayed
only at the full-mode setting.
1. Confirm the LCD panel is on.
2. Press
button within 0.5 seconds.
3. Release
button to switch the mode.
4. Repeat steps 2 and 3 until your desire mode is displayed.
5. Switching the mode after measurement converts the results to the new
mode.
6. After the mode is set, measurements are performed in the new mode.
7. Switching Full/Limited modes (default setting is limited mode)
1. Confirm the power is off (LCD is off).
2. Press and hold
button, then depress and hold button
within 0.5 second.
3. Continue to press and hold both buttons, (more than 2 seconds),to
confirm the internal display is on.
When these buttons are pressed, all symbols are displayed . When
『
』and 『 』symbols do not a ppear , Limited mode is
switched to Full mode.
Note) If buttons are not pressed in the correct order , switching will
not take place.
Note) This mode change can also be confirmed when s witching the
measurement/display mode.
4. Release buttons.
8. Distance display
Nikon Callaway id TECH is F irst T arget Priority Distance Display System.
When obtaining different results from a single measuring operation. The Nikon
Callaway id TECH will display the distance to the nearest target on the LCD
panel.
ex.) When measuring a tree standing in front of a house;
"115m" (distance to the tree) will be displayed. This mode has application for
golf.
9. Low battery indication
Flashing
indicates that the batter y charge is low and batter y should
be replaced. (See "Changing Battery")
Optical system
T ype Roof-prism monocular
Magnification 6x
Effective diameter of objective lens (mm) ø21mm
Angularfieldofview(real) 6.0°
Eye relief (mm) 18mm
Exit pupil (mm) ø3.5mm
Dioptreadjustment ±4m
-1
Others
Operatingtemperature -10°—+50°
Power source CR2 lithium battery x 1, 3V DC,
Auto Power Off (appr ox. 30 seconds)
Dimensions(DxWxH) 130x45x69mm
W eight Approx.210g(withoutbattery)
Structure Body:W aterproof(maximumdepthof1meter
for up to 10 minutes)*
(Batterychamber:W aterresistant**)
Safety&EMC Class1MLaserproduct(IEC68025-
1:2001)
FCC Part15 subpart B Class B
CE,EMCdirective,c-tick,WEEE
* W aterproof models
The Nikon Callaway id TECH is waterproof, and will suffer no damage to the
optical system if submerged or dropped in water to a maximum depth of 1 meter
for up to 10 minutes.
The Nikon Callaway id TECH offers the following advantages:
• Canbeusedinconditionsofhighhumidity ,dustandrainwithoutriskof
damage.
• Nitrogen-filleddesignmakesitresistanttocondensationandmold.
Observe the following when using the Nikon Callaway id TECH.
• Astheunitdoesnothaveaperfectlysealedstructure, itshouldnotbe
operated nor held in running water .
• Anymoistureshouldbewipedoffbeforeadjustingmovableparts(eyepiece,
etc.) of the Nikon Callaway id TECH to prevent damage and for safety reasons.
T o keep your Nikon Calla way id TECH in excellent condition, Nikon Vision
recommends regular servicing by an authorized dealer .
** The batter y chamber is water resistant, not waterproof. Water may enter the
device if the Nikon Callaway id TECH is submerged in water . If water enters
the battery chamber , wipe out any moisture and allow time for the chamber to
dry .
T r oubleshooting/Repair
If p rob le ms p er s is t af te r co nsu lt ing t he Troub le sh oot ing Tabl e,
pl ea se c ont ac t you r lo ca l de al er to c he ck /rep ai r the N ikon
Cal law ay id T ECH. N eve r let a nyo ne th an t he of f ic ia l
re pr es ent at ive of t he p rod uc t ma nu fac tu re r che c k or re pa ir t he
Niko n Ca lla way id T ECH . Fail ur e to fol low th is i ns tr uc tio n co ul d
re su lt in i nju r y, or da mag e to th e pr odu ct .
Symptom Check Points
Unit does not turn on —
LCD fails to illuminate
T arget range cannot be
obtained
[- - -] (“Cannot
measure”) appears
Closer target cannot be
measured
T arget beyond a certain
distance cannot be
measured
Measurement result is
unstable
Incorrect result is
displayed
•DepressPOWERbutton.
•Checkandreplacebatteriesifnecessary.
•Besurethatnothing,suchasyourhandorfinger ,is
blocking the laser emission aperture and laser
detector .
•Besurethatthelaseremissionapertureandlaser
detector are clean. Clean them if necessary .
•Besurethatthetargetshapeandconditionis
appropriate to reflect the laser beam.
•Replacebattery.
•Besuretoholdtheunitsteadywhiledepressingthe
POWER button.
•Besurethetargetiswithinmeasuringrange(10-
500m/11 - 550 yards/33-999 feet)
•Besurethatnothing,suchasleavesorgrass, is
between the Nikon Callaway id TECH and the target.
•Besurethatnothing,suchasleavesorgrass, is
between the Nikon Callaway id TECH and the target.
•Replacebattery.
•Besurethatthetargetshapeandconditionis
appropriate to reflect the laser beam.
•Besuretoholdtheunitsteadywhiledepressingthe
POWER button.
•Besurethatnothing,suchasleavesorgrass, is
between the Nikon Callaway id TECH and the target.
•Replacebattery.
•Besurethatthetargetshapeandconditionis
appropriate to reflect the laser beam.
•Besurethatnothing,suchasleavesorgrass, is
between the Nikon Callaway id TECH and the target.
If your Nikon Callaway id TECH should require repair , please contact your local
dealer for details regarding where to send it. Before doing so, you are advised to
consult the T roubleshooting T able below.
Do not use the Nikon Callaway id TECH for purposes beyond the limits of its
stated accuracy .
This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules and to EU EMC
directive. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequenc y energy and, if not
installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However , there is no guarantee that
interference will not occur in a particular installation. If this equipment
does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the
following measures:
•Reorientorrelocatethereceivingantenna.
•Increasetheseparationbetweentheequipmentandreceiver .
•Consultthedealeroranexperiencedradio/TVtechnicianforhelp.
This Class B digital apparatus meets all requirements of the Canadian
Interference-Causing Equipment Regulations.
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two condition0s:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, inc luding interference
that may cause undesired operation.
E
T ree F ence House
Distance to T arget 115m 123m 128m
MeasurementSystem
Measurementmode Linear distance : Act
display Horizontal distance : Hor
Height : Hgt
Angle : Ang
V ertical separation
(height between two points ): Hgt + Hgt2
Measureddistance/ Distance: 10-500meters/11-550yar ds/33-999feet
angle range (999 feet: 304.5 meters/333 yards)
Angle:
±89°
Distance- Act 0.5 m ete r/y ard , 1 .0 fo ot ( < 100 meters /yards /feet)
An gle
( Li ne ar d ist an ce )
1 .0 me ter /ya rd, 1.0 foot ( ≧ 1 0 0 met ers /yards /feet)
Di spl ay Ho r 0. 2 mete r/ yar d, 0. 5 foo t
( < 1 0 0 meters /yards /feet)
Ste ps
( Ho ri zon ta l dis t. )
1.0 mete r/ yar d, 1.0 foot ( ≧ 1 00 meters/yards /feet)
Hgt 0. 2 met er/ ya rd, 0. 5 foo t ( < 1 00 meters /yards/feet )
( Height)
1 .0 me ter /ya rd, 1.0 foot ( ≧ 100 meters/yards /feet )
An g
(Angle )
0. 1 °( < 10° ),1.0° ( ≧ 10 ° )
Linear distance
0. 5 mete r/ yar d, 1.0 foot
Horizontal di st.
0.2 m ete r/y ard , 0.5 fo ot
Height 0 .2 m ete r/y ar d, 0.5 fo ot
Angle 0 .1°
System First T ar get Priority Distance Display system
Internal
External
Laser
Class IECClass1M
W avelength 870nm
Pulse duration 14 ns
Output 15W
Beam divergence V ertical:5°—8°,Horizontal:25°—36°
Operating humidity 80% RH (without dew condensation)
Laser Rangefinder
8
6
1
3
7
4
2
!e
!w
!q
9
!p
5