Setup: Connecting the SCSI Cable
SCSI devices are connected to the computer in a “daisy chain.”
Up to eight devices, including the computer and any internal
SCSI devices such as hard drives and CD-ROM drives, can be
connected in a SCSI chain. The first and last devices in the
chain must be terminated, i.e., fitted with special circuitry to
reduce noise, making the connection more reliable. If the
LS-2000
is the last device in the chain, it can be terminated
using the termination switch on the rear of the scanner. Except
in the case of some laptop computers requiring external termi-
nators, the other end of the chain will be terminated inside the
computer, either at the SCSI adapter or at an internal drive. In
the case of IBM PC/AT computers with internal SCSI devices, it
may be necessary to remove termination from the SCSI adapter
board before connecting external devices.
To connect the scanner to the SCSI chain, a SCSI cable with a
male half-pitch 50-pin connector is required. The other end of
the cable must match the connector on the devices to which
the scanner is to be connected. For direct connection to most
Macintosh computers, a 25-pin D-sub connector will be re-
quired (Macintosh laptop computers use a different type of
connector). SCSI boards for IBM PC/AT computers will usually
be provided with a 25-pin D-sub connector, a 50-pin Centronics
connector, or a half-pitch 50-pin connector with the pins ar-
ranged in two separate rows or attached to a central “finger.” If
the correct type of cable is not available, an adapter can be
attached to one or both ends of the cable. To prevent interfer-
ence, SCSI cabling should be of a high-impedance type and be
as short as possible. The total length of cabling in a SCSI chain
must not exceed six meters (twenty feet), but be aware that
the reliability of the SCSI interface will drop as the length of the
cable increases.
A SCSI cable is provided with scanners sold in the United States
and Canada. If your scanner was purchased in another region,
before connecting the SCSI cable you should attach the ferrite
core provided with your scanner (the cable provided to cus-
tomers in the United States and Canada does not require a
core). Place the SCSI cable in the center of the open core and
close the core tightly. The core should be attached as far as
possible from the scanner; i.e., as close as possible to the other
device to which the cable is attached. Attach the plastic tie on
the scanner side of the core to prevent the core from sliding
out of position.
1. Close and latch core
To LS-2000
2. Place tie around cable
and pull tight
22

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Nikon COOLSCAN_LS2000 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Nikon COOLSCAN_LS2000

Nikon COOLSCAN_LS2000 Bedienungsanleitung - Deutsch - 45 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info