4
Multiple Flash Photography
type) or AI-P lenses to perform Center-Weighted or
Spot Fill-Flash, or (3) performing Standard TTL Flash.
* Because 3D Multi-Sensor and Multi-Sensor Balanced Fill-Flash take advan-
tage of the SB-25s Monitor Preflash and the cameras TTL Multi-Sensor, it is
difficult to manage such fill-flash operations for TTL Multiple Flash
Photography, especially when using the SB-25 as a master flash unit with
other slave flash unit(s). The Sensor system is designed to analyze Monitor
Preflash reflection from a single SB-25 (ideally, mounted on the camera) and to
control light output from that particular unit, but not from the other slave(s).
Use optional Multi-Flash Sync Cord SC-18 (1.5m) and/or
SC-19 (3m) to connect flash units via the SB-25s TTL
multiple flash terminal. Remove the rubber cover to use.
Use optional TTL Remote Cord SC-17 or SC-24* for use
with the SB-23, SB-22, SB-21B, SB-20, SB-18 and/or
SB-15 as a master flash unit.
* Used for F4-Series with the DW-20 or DW-21 attached.
Use optional TTL Multi-Flash Adapter AS-10 for use with
the SB-22, SB-21, SB-20, SB-18 and or SB-15 as a slave
flash unit.
Use optional TTL Remote Cord SC-23 for use with the
SB-140, SB-14 and/or SB-11.
The SB-11/14/140 (even with SC-23) or SB-21 cannot be
used for TTL multiple flash photography with the F-401/
N4004 and F-401s/N4004s.
When a second shot cannot be taken (F90-
Series/N90, F4-Series, F-801/N8008, F-801s/
N8008s, F-601/N6006, F-601M
/N6000, F-401x/
N5005, and F-501/N2020)
For multiple flash photography, if the electronic current
in the synchro circuit exceeds a certain level, you may
not be able to take a second shot after taking the first
shot.
Take care that the combined total of the coefficients
(numbers shown in parentheses below) for all
Speedlights used at any one time does not exceed 20
at 20°C (68°F), or 13 at 40°C (104°F).
If you are unable to take a second shot, disconnect
the master Speedlight from the camera, or turn each
of the Speedlights off once. This resets the circuits so
you can resume shooting.
Speedlight coefficients
SB-25 (1) SB-24 (1) SB-23 (4) SB-22 (6) SB-21 (4)
SB-20 (9) SB-19 (2) SB-18 (16) SB-17 (4) SB-16 (4)
SB-15 (4) SB-14 (1) SB-12 (1) SB-11 (1)
Manual Multiple Flash Photography
Use the sync/multiple flash terminal for connection with
other Speedlights via optional sync cords.
Use optional Sync Cord SC-11 or SC-15.
Set and use Manual Flash mode on each Speedlight
for correct exposure.
Speedlights for TTL multiple flash photography
Master
Slave
SB-25, SB-24, SB-23, SB-22, SB-21B, SB-20,
SB-18, SB-16B or SB-15
SB-25, SB-24, SB-22, SB-21B, SB-20, SB-18,
SB-17, SB-16A, SB-16B and/or SB-15
TTL Multiple Flash Photography
Use the TTL multiple flash terminal for connecting other
Speedlights via optional sync cords.
You can use one Speedlight for the master flash unit and
up to four other units for slaves.
See the following chart to confirm available Speedlights
for master and slave use.
Note the following when using an F90-Series/N90 camera
for TTL Auto Flash operation with multiple Speedlights:
a. Use the SB-25 as a slave flash unit whenever possi-
ble, or
b. When using the SB-25 as master, avoid Monitor
Preflashes* by (1) upward tilting or rotating the flash
head (the distance indicator bars disappear),
(2) using a lens other than AF Nikkor (including D-
Use the ON position to activate a slave flash unit; the
STBY does not function (SB-25, SB-24, SB-22 and
SB-20).
The SB-23 offers only OFF and TTL/STBY positions for
power switching. This means it cannot be used as a slave.
SB-25_En 03.1.14 8:18 PM Page 128
65

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Nikon SB-25 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Nikon SB-25

Nikon SB-25 Bedienungsanleitung - Deutsch - 73 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info