12129200. 12149200. Replacement with the new 1200W motor kit A-0.6.5.
1
ASSEMBLY INSTRUCTIONS GM 200 / 300 / 400 SERIES
Instruction No. 82129400/00-08
To be performed by a skilled
or instructed person only !
Disconnect the vacuum cleaner
from the power supply before
starting the work!
! Models with bag-full indicator:
Open the dust cover until it stops
and continue with a little pressure
by hand until it slides free of the
hinges.
Models with no bag-full indicator:
Open the dust cover and lift it out
of the hinges.
Remove filter with dust bag.
Remove the dust bag holder by
pressing bottom clip and ease the
holder out of the bottom. This
releases the hook at the container
wall.
@ To separate the top and bottom
housing and avoid scratches on
the parts, place tool no. 22361400
under the buffer.
Follow instruction 82361500
Remove the strap (12) by hand.
Lift up the buffer and remove the
top housing.
# Free the cord with plug from
the terminal box in the top housing
by using a Pozi screwdriver no. 2
or in old models press it out by
hand.
Remove the cord reel and lock the
cord to the reel. Remove internal
wires and release the on/off switch
by pressing a screwdriver under it.
Remove the motor housing with
four screws by a Pozi screwdriver
no. 2.
Replace the motor unit with the
new complete motor housing
included the thermal switch and
connect wires as described.
Refit in reverse order. Press the
buffer back in place by hand after
mounting the strap around the
housings.
WE
Q
12