word mark and logo are registered trademarks owned by Bluetooth SIG, Inc.
Bluetooth Security
The Bluetooth radio contained in the 3240 is a Bluetooth Smart single-mode, low-energy radio. It supports
a GATT-based, proprietary Nonin profile to transmit current readings from the patient. Data is not stored
by the 3240 to be transferred at a later time. The 3240 supports an encryption key size of 128 bits. While
the 3240 is in a Bluetooth connection, it will be unavailable for other connections. Apart from the standard
Bluetooth security measures, Nonin has implemented a non-standard security measure to the 3240 that, if
used, will restrict the transfer of data to only devices with a specified organizationally unique identifier
(OUI).
For additional technical information, please see the insert, “NoninConnect Elite Model 3240 Technical
Description.”
SymbolDefinitionSymbolDefinition
!
Caution!
Not for continuous monitoring (no
alarm for SpO
2
)
Follow Instructions for Use.Battery orientation
Consult Instructions for Use.
IP32
Protected against vertically falling
water drops when enclosure is tilted up
to 15 degrees and ingress of solid
foreign objects greater than or equal to
2.5 mm (0.1 in.) in diameter per
IEC 60529.
MR
MR
MR unsafe
Type BF Applied Part (patient
isolation from electrical shock)
UL Mark for Canada and the United
States with respect to electric shock,
fire, and mechanical hazards only in
accordance with IEC 60601-1,
UL 60601-1 and CAN/CSA-C22.2
No. 601.1.
SN
Serial Number
BDA
Bluetooth Device Address
+70C
-40C
Storage/shipping temperature range of
-40 °C to 70 °C (-40 °F to 158 °F)
CE Marking indicating conformance
to EC Directive No. 93/42/EEC
concerning medical devices.
Handle with care
Radio Equipment Class IdentifierKeep dry
Non-ionizing electromagnetic
radiation. Equipment includes RF
transmitters. Interference may occur in
the vicinity of equipment marked with
this symbol.
Medical prescription required
Manufacturer
Indicates separate collection for
electrical and electronic equipment
(WEEE)
EC
REP
Authorized Representative in the
European Community
REF
REF
Catalogue number
MR
MR
•applying the pulse oximeter on
the same arm as a blood
pressure cuff, arterial catheter
or infusion line(s) (IVs)
•excessive light, such as sunlight
or direct home lighting
•excessive motion
•moisture in the device
•improperly applied device
•finger is outside recommended
size range
•poor pulse quality
•venous pulsations
•cardiogreen and other
intravascular dyes
•anemia or low hemoglobin
concentrations
•carboxyhemoglobin
•methemoglobin
•dysfunctional hemoglobin
•artificial nails or fingernail
polish
SymbolDescription
Nonin’s CorrectCheck™ senses that the finger has not been correctly inserted. If
you see this symbol, slide finger further into device.
The number next to this symbol is the amount of oxygen in your blood (functional
oxygen saturation of arterial hemoglobin).
The number next to this animated symbol is your pulse rate. Pulse rate is the
number of times your heart beats per minute.
– – –
Dashes replace the readings when the 3240 is unable to detect a usable signal.
White symbol – Radio is on.
Green symbol – 3240 is connected.
Flashing white symbol – Connection error. The radio will reset.
Poor signal. Steady your hand, reposition finger, warm finger by rubbing, or select
a different finger.
Low battery. Replace batteries.
Critical battery. Flashing indicator on full screen. The device will not work until the
batteries are replaced.
Nonin Medical, Inc.
13700 1st Avenue North
Plymouth, Minnesota 55441-5443 USA
(800) 356-8874 (USA/Canada)
+1 (763) 553-9968 (outside USA and Canada)
Fax: +1 (763) 553-7807
E-mail: technicalservice@nonin.com
Nonin Medical B.V.
Prins Hendriklaan 26
1075 BD Amsterdam, Netherlands
+31 (0)13 - 79 99 040 (Europe)
Fax: +31 (0)13 - 79 99 042
E-mail: technicalserviceintl@nonin.com
nonin.com
707580859095100
−6−4−20246
SaO
2
(%)
SpO
2
−SaO
2
(%)
Bias=0
Limits of Agreement
Linear Regression
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
22
2
3
3
3
3
3
3
3
3
3
3
3
3
33
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
44
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
6
6
6
6
6
6
6
6
6
66
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
7
7
7
7
7
7
7
7
7
7
7
7
77
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
88
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
10
10
10
1010
10
10
10
10
10
10
10
10
10
10
10
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
1111
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
14
14
1414
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
SpO
2
−SaO
2
(%)
Finger
Thumb
Accuracy Summary – Finger and Thumb
Range
Specified Oxygen
Saturation (A
rms
)
Thumb Oxygen
Saturation (A
rms
)
Low Perfusion
Oxygen Saturation (A
rms
)
70 – 100%± 2± 1.56± 2
70 – 80%± 2± 1.91± 2
80 – 90%± 2± 1.21± 2
90 – 100%± 2± 1.49± 2
Finger Oxygen
Saturation (A
rms
)
± 1.31
± 1.65
± 1.05
± 1.18
This graph shows plots of the
error (SpO
2
– SaO
2
) by SaO
2
using the 3240 with a linear
regression fit and upper 95% and
lower 95% limits of agreement.
Each sample data point is
identified by subject from a
clinical study in non-motion
conditions.
Brauchen Sie Hilfe? Stellen Sie Ihre Frage.
Missbrauch melden von Frage und/oder Antwort
Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.
Art des Missbrauchs:
Forenregeln
Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:
Lesen Sie zuerst die Anleitung;
Schauen Sie nach, ob die Frage bereits gestellt wurde;
Stellen Sie die Frage so deutlich wie nur einigermaßen möglich;
Erwähnen Sie was Sie bereits versucht haben um das Problem zu lösen;
Ist Ihr Problem von einem Besucher gelöst dann lassen Sie ihn / sie wissen in diesem Forum;
Falls Sie reagieren möchten, so verwenden Sie bitte das Antworten- Formular;
Da ihre Frage für alle Besucher sichtbar ist, sollten Sie lieber keine persönliche Daten erwähnen.
Neu registrieren
Registrieren auf E - Mails für Nonin Connect Elite 3240 wenn:
neue Frage gestellt werden
neue Handbücher vorhanden sind
Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.
Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.
Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.
Ihre Frage wurde zu diesem Forum hinzugefügt
Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.