625427
57
Zoom out
Zoom in
Vorherige Seite
1/60
Nächste Seite
GROUP
TF
EN
EN
u
HR EVO14
TF01
AUGER AT LIGTHING UP
TON time of the gear motor during the “WAITING FLAME” phase
sec
3,6
TF02
AUGER MAX CHARGE
maximal interval time for the pellet pre-loading
min
4
TF31
IGNITIONSMOKE SPEED
inflow in the firepot during the “WAITING FLAME” phase
g/min
1350
TF04
PRE-HEAT RESISTANCE
pre-heating time of the resistance
sec
180
TF05
DELTA FLAME
flame increasing value to go to next phase
°C
7
TF06
PUMP THRESHOLD
smoke temperature threshold for starting exchanger
°C
51
TF07
RE-START THRESHOLD
reference threshold for restart
°C
80
TF59
FAN THRESHOLD
reference threshold for fan activation
°C
60
TF08
AUGER AT STATR UP
ON time of the gear motor during the “FLAME LIGHT” phase
sec
2,6
TF09
MINUTES START
Time for the stabilization of the flame during the “FLAME LIGHT” phase
min
8
TF32
START SMOKE SPEED
inflow in the firepot during the “ FLAME LIGHT” phase
g/min
1500
TF11
ACTIVATION CLEANER
ON time of the gear motor during the “FIRE POT CLEANING” phase
str
OFF
TF12
CLEANING FREQUENCY
Duration of the firepot cleaning operation
min
30
TF13
CLEANING DURATION
Interval of time between two fire pot cleaning operations
sec
20
TF14
SUCTSMOKE CLEANING
Smoke suction speed during the “FIRE POT CLEANING PHASE”
g/min
2500
TF18
AUGER CLEANING
Working time of the pellet motor during the automatic cleaning
sec
1,4
TF21
SEC. AUTOM. CLEANING
WORKING TIME OF AUTOM. CLEANING DEVICE
sec
30
TF27
AUTOM. CLEANING STROKES
Number of stokes of the automaic cleaning during each cleaning cycle
num
5
SWITCH OFF
TF15
OFF THRESHOLD
threshold for START (tsmoke<=pr13) or RESTART (tsmoke>pr13)
°C
50
TF16
AUGER AT MODULATION
ON time of the gear motor during the work phase at power MOD.
sec
2
TF17
FLOW POWER mod
inflow in the firepot during the work phase at power MOD.
m/s
1,45
TF19
AUGER MIN POWER
primary exchanger voltage during the work phase at power MIN
sec
2
TF20
FLOW POWER min
ON time of the gear motor during the work phase at power MIN
m/s
1,45
TF22
AUGER MAX POWER
inflow in the firepot during the work phase at power MAX
sec
5,3
TF23
FLOW POWER max
primary exchanger voltage during the work phase at power MAX
m/s
1,65
TF25
AUGER POWER AT SANI
ON time of the gear motor during the work phase at power SANI
sec
5,3
TF26
FLOW POWER sani
inflow in the firepot during the work phase at power SANI
m/s
1,65
TF33
SMOKE SPEED I mod
Smoke suction speed during work phase at MOD
g/min
1300
TF34
SMOKE SPEED min
Smoke suction speed during work phase at MIN
g/min
1300
TF35
SMOKE SPEED max
Smoke suction speed during work phase at MAX
g/min
1600
TF36
SMOKE SPEED sani
Smoke suction speed during work phase at SANI
g/min
1700
ALTITUDE
TF38
ALTITUDE
Value of the altitude from the sea level
metri
0
ON/OFF RDS
TF39
ON/OFF FLOW METER
disable “OFF” or enable “ON” the RDS function
val
S.Aut
RECIPE
TF40
RECIPE ACTIVE
OFF/scarce/low/medium/high draught
str
OFF
TF54
DELTA BOILER
Delta temp. to activate heating of the sanitay water (available from vers. 04)
°C
5
TF55
DELTA PUFFER
Delta temperat. to activate heating on water tank (available from vers. 04)
°C
5
TF41
THRESHOLD NO PELLET
Reference threshold for “NO PELLET” alarm
°C
45
TF42
MAXIMUM THRESHOLD
Maximum temperature threshold during working phase
°C
270
TF43
DELAY ALARMS
delay alarms activation
sec
60
TF44
BLACK OUT
limit seconds for the activation of the “BLACK OUT” alarm
sec
10
TF45
REIGNITION BLOCK
START or RESTART (VENTILATION) waiting time
min
3
TF46
T-OFF MINIMUM
Reference threshold for “NO PELLET” alarm
min
4
TF47
MINIMUM INFLOW
Minimum inflow
m\s
0,5
TF48
MAX DURATION IGNITION
Maximum time for an ignition cycle
min
18
TF37
MAX. WATER TEMPERATURE
Water temperature for starting circolator
°C
90
TF49
CANCELL PRESSURE
CANCELL PRESSURE READING WITH PRESS. TRASDUCER
on/off
OFF
TF50
FREQUENCY XHZ
NET FREQUENCY
Hz
50
TF51
DEGREES
measuring unit for the temperature
°C/°F
°C
TF52
DRAUGHT USER
Option to activate to allow the user ti set darft and pellet
on/off
ON
TF53
SERVICE HOURS
enable/disable resistance
h
2500
TF30
ACTIVATION FAN
PARAMETER RELATED TO ACTIVATION OF AIR AXCHANGE HEATER
str
OFF
TF28
FAN SPEED MOD
EXCHANGER VOLTAGE DURING WORKING PHASE AT POWER mod
v
160
TF29
FAN SPEED SANI
XCHANGER VOLTAGE DURING WORKING PHASE AT POWER SANI
v
210
TF56
VOLT MAX
Volt mx
v
230
TF57
MAXIMUM POWER
Maxiumum power setting (MIN MED MAX)
str
P MAX
SANITARY
POWER
SMOKE SPEED
DELTA
BOILER/PUFFER
ALARMS
EXTRA
PARAMETERS
IGNITION
MAXIMUM
POWER
FLAME LIGHT
CLEANING
BRAZIER
MODULATION
POWER
MINIMUM
POWER
HR EVO14 EN
93
57

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Nordic Fire HRV170 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info