542372
19
Zoom out
Zoom in
Vorherige Seite
1/56
Nächste Seite
FIAMMETTA BIIGIORGIA BIIASIA BIIFIORELLA BIILUCY BII
7196601 – EN 19
A too small section causes a decrease of the draught. It is suggested
a minimum height of 4 m.
The following features are forbidden and therefore they endanger the
good operation of the appliance: asbestos cement, galvanized steel,
rough and porous internal surfaces. Picture 3 gives some examples
of execution.
The minimum section must be 4 dm
2
(for example 20 x 20 cm’s)
for appliances whose duct diameter is lower than 200 mm, or
6.25 dm
2
(for example 25 x 25 cm’s) for appliances with diameter
greater than 200 mm.
The draught created by the flue must be sufficient, but not excessive.
A too big flue section can feature a too big volume to be heated and
consequently cause difficulties in the operation of the appliance; to
avoid this, tube the flue along its whole height. A too small section
causes a decrease of the draught.
The flue must be properly spaced from any flammable materials
or fuels through a proper insulation or an air cavity.
It is forbidden to let plant piping or air feeding channels pass in the
same flue. Moreover, it is forbidden to create movable or fixed
openings on the same for the connection of further other appliances.
5.1. CHIMNEY CAP
The draught of the flue depends also on the suitability of the
chimney cap.
Therefore, if it is handicraft constructed, the output section must be
more than twice as big as the internal section of the flue. Should it be
necessary to exceed the ridge of the roof, the chimney cap must
assure the discharge also in case of windy weather (Picture 4).
The chimney cap must meet the following requirements:
have internal section equivalent to that of the stack.
have a useful output section twice as big as the flue internal one.
be manufactured in such a way as to prevent the penetration of rain, snow, and any other foreign body in the
flue.
be easily checkable, for any possible maintenance and cleaning operation.
Picture 3
Picture 4
Picture 5
A+1/2A
A
Max.
A+1/2A
(3)
(1)
(2)
(4)
(1) AISI 316 steel flue with double
chamber insulated with material resistant
to 400°C. Efficiency 100% excellent.
(2) Refractory flue with double insulated
chamber and external coating in
lightweight concrete. Efficiency 100%
excellent.
(3)
Traditional clay flue square section
with cavities. Efficiency 80% excellent.
(4) Avoid flues with rectangular internal
section whose ratio differs from the
drawing.
Efficiency 40% poor.
(1) Industrial chimney cap
with pre-
fabricated
elements
it allows an
excellent discharge of the
smokes.
(2) Handicraft chimney cap.
The right output section must
be at least twice as big as the
internal section of the flue
(ideal value: 2.5 times).
(3) Chimney cap for steel
flue with conical deflector
of smokes.
50 cm
(1) In case of flues side by side, a chimney cap must be higher
than the other one of at least 50 cm in order to avoid pressure
transfers between the flues themselves.
19

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für La Nordica LUCY wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info