564479
22
Zoom out
Zoom in
Vorherige Seite
1/28
Nächste Seite
22
Green Status Indicator Fault Possible Cause Effect on Product Investigate the Following Action Required If fault persists
1 Flash with pause Batteries voltage low Batteries not been charged
Possible bad connection between
batteries, controller, charger or fuses
caused by loose connections,
damaged wiring, water ingress
Not accepting charge due to faulty
battery/cell
Charger not functioning
Operating time
severely reduced
or machine will not
operate
Check when machine last charged
Switch OFF the machine :
Remove Fuses
Check connections to batteries, charger and
fuses for loose wires or screws
Check each battery Voltage individually to
detect defect unit 10.5V min
Check battery voltage and charge current
ensuring charger red fault light is
extinguished
Charge batteries immediately
Tighten loose connections and
replace damaged components
Replace batteries as required
Replace charger
Contact
Service
Agent
2 Flashes with pause Traction motor
disconnected
The motor has a bad connection
Motor disconnected
TCO activated
(Thermal cut Out)
Motor failed open circuit
Motor will not operate Check all connections and leads between the
motor and controller
Tighten loose connections and
replace damaged
components - check exhaust
clean if necessary.
3 Flashes with pause Traction motor wiring
Trip
The motor has a short circuit to a
battery
Motor will not operate Check all connections and leads between the motor and controller
4 Flashes with pause Battery Lockout The battery charge level has fallen
below the battery lockout level and
the controller is inhibiting machine
functions
Machine functions not
working
Check battery voltage and charge current
ensuring charger red fault light is extinguished
Check each battery Voltage individually to
detect defect unit 10.5V min
Charge batteries immediately
6 Flashes with pause Charger Connected The controller is being inhibited from
driving, This may be because the
battery charger is connected
Machine functions not
working
Remove Charger to operate machine
8 Flashes with pause Controller Trip A controller trip is indicated Machine functions not
working
Check all connections and leads Tighten loose connections and
replace damaged components
9 Flashes with pause Brake Deactivated
or Failed
Poor brake connections.
Brake failure or deactivation
Traction drive
disabled
Check brake wiring and brake lever Replace brake or wiring as
necessary.
Reactivate brake by engaging
brake lever.
10 Flashes with pause High Battery Voltage Poor connections between battery
controller and traction motor
Machine functions not
working
Check each battery Voltage individually to
ensure voltage < 14 volts
Check connections on controller, batteries and
traction motor
Check combined battery pack voltage is < 28
volts
Green Flashing Warning light.
Warning light ashes explained
22

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Numatic TTV - 5565- 200T wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info