While operating in NORM or GAUG Mode the Audible will emit 1 beep per second for 10 seconds when alarms strike, unless it is set Off. During that
time, the Audible can be acknowledged and silenced by pressing the S button (less than 2 seconds).
A LED Warning Light, on the lower end of the housing, is synchronized with the Audible and flashes as the Audible sounds. It will turn Off when the Alarm
is silenced. The Audible and LED will not be active if the Audible is Set OFF (a group A setting).
FREE Dive Mode has its own set of Alarms which emit 3 short beeps either 1 or 3 times which cannot be acknowledged or set Off.
Situations that will activate the NORM/GAUG 10 second Alarm include -
** Items activate only in NORM mode.
• Air Time Remaining (ATR) at 5 minutes, then again at 0 minutes.
• Turn Pressure at the Set Point selected (Transmitter 1 only).
• End Pressure at the Set Point selected (active Transmitter).
• Descent deeper than the Depth Alarm Set Point selected.
• Dive Time Remaining at the Set Point selected**.
• Elapsed Dive Time at the Set Point selected.
• PO2 at the Set Point selected**.
• High O2 of 300 OTU (100%)**.
• TLBG at the Set Point selected**.
• Ascent Rate exceeds 60 FPM (18 MPM) when deeper than 60 FT (18 M), or 30 FPM (9 MPM) at 60 FT (18 M) and shallower.
• Loss of the active Transmitter Link signal for more than 15 seconds during a dive.
• Entry into Decompression Mode (Deco)**.
• Conditional Violation (above a required Deco Stop Depth for less than 5 minutes)**.
• Delayed Violation (above a required Deco Stop Depth for more than 5 minutes)**.
• Delayed Violation (a Deco Stop Depth greater than 60 FT/18 M is required)**.
• Delayed Violation (Max Operating Depth of 330 FT/100 M is exceeded).
• A Gas Switch would expose the diver to PO2 => 1.60 ATA**.
• Watch Daily Alarm reaches time set (disabled during Dive Modes).
• Watch Mode Countdown Timer reaches 0:00.
A single short beep (which cannot be disabled) sounds when -
• After 5 minutes on the surface after the Violation dive.
3 short beeps (which cannot be disabled) sound when -
• Ascent Rate is 51 to 60 FPM (15.1 to 18 MPM) when deeper than 60 FT (18 M), or 26 to 30 FPM (7.5 to 9 MPM) at 60 FT (18 M) and shallower.
• FREE Dive Elapsed Dive Time Alarm (3 beeps every 30 seconds if set On).
During the following NORM Dive situations, the 10 second continuous tone will be followed by a 5 second steady beep that will not turn off when acknowl-
edged -
• Ascent above a Deco Stop for more than 5 minutes.
• Deco requires a Stop Depth of 70 FT/21 M or deeper.
• On the Surface for 5 minutes after a Conditional Violation.
PC INTERFACE
Interface with a PC, to allow uploading settings and downloading data, is accomplished by connecting the OC1 to a PC USB Port using the special OC1
USB Interface Cable.
The software program together with the USB Driver required is on the Oceanlog CD, and can be downloaded from the OceanicWorldwide web site. The
program's HELP** serves as the user manual which can be printed for personal use.
** Prior to attempting to Download data from your OC1 or Upload Settings to it, review the HELP section of the Oceanlog program. Recommended is to
print those sections of HELP that you consider appropriate for your Interface activities.
The Settings Upload portion of the Oceanlog program can be used to set/change the Main Time, Date, Set A group (Alarms), and Set U group (Utilities)
using the same Interface System. FO2 and FREE Mode related items must be set using the control buttons.
Information available for retrieval (download) from the OC1 to the PC Download portion of the program includes dive data such as number, surface inter-
val time, maximum depth, elapsed dive time, no deco status, pressure, start date/time, lowest temperature under water, sampling rate, dive profile, and Set
Points.
The Oceanlog program also allows upgrade of select versions of the OC1's firmware (operating system software) after which the OC1 resets all operating
data. Since the upgrades require reset of the OC1, they are blocked during 24 hours after dives.
• Refer to page 58 for more details relating to Oceanlog and PC Interface.
Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.
Art des Missbrauchs:
Forenregeln
Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:
Lesen Sie zuerst die Anleitung;
Schauen Sie nach, ob die Frage bereits gestellt wurde;
Stellen Sie die Frage so deutlich wie nur einigermaßen möglich;
Erwähnen Sie was Sie bereits versucht haben um das Problem zu lösen;
Ist Ihr Problem von einem Besucher gelöst dann lassen Sie ihn / sie wissen in diesem Forum;
Falls Sie reagieren möchten, so verwenden Sie bitte das Antworten- Formular;
Da ihre Frage für alle Besucher sichtbar ist, sollten Sie lieber keine persönliche Daten erwähnen.
Neu registrieren
Registrieren auf E - Mails für Oceanic OC1 wenn:
neue Frage gestellt werden
neue Handbücher vorhanden sind
Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.
Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.
Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.
Ihre Frage wurde zu diesem Forum hinzugefügt
Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.