Technical Data
Nominal thermal output ................................................5,0 kW
Room heat output ......................................................... 5,58 kW
Connection pipe........................................................Ø 150 mm
max. Weight ........................................................................150 kg
Connection combustion air ..................................Ø 125 mm
Operating mode .................................. Intermitting burning
Regulations to be observed
Local and building law regulations
The stove must be installed by a professional and con-
nected to the chimney. The specic national regulations
for safe installation of the connector must be complied
with. The connecting piece used must possess an open-
ing for cleaning.
The stove must be regularly checked by a professional.
The stove has national technical approval from the
Deutsches Institut für Bautechnik (DIBt) (German
Institute for Civil Engineering) for room-air independ-
ent operation.
Due to its general technical approval, the stove can be
used simultaneously with an approved ventilation sys-
tem without additional safety device.
Equipped with a self-closing combustion chamber door,
the stove is approved to be connected to multi-ue chim-
neys provided that it operates with a room-air dependent
combustion-air supply.
Room-air independent operation requires that the exhaust
gases of the replace be discharged through a single-ue
chimney or the exhaust duct of a single-ue air-exhaust
chimney. Exhaust gases may also be discharged into multi-
ue exhaust gas systems if all connected replaces are part
of the same utilisation unit/action range of the ventilation
system. Individual dierences can be discussed with your
district master chimney sweep.
Chimney design
The chimney design is according to DIN EN 13384 -1 and
-2 or to the specic national regulations.
The chimney must comply with the temperature class
T400.
Necessary data
Closed operation
with billet wood / wood briquettes:
Nominal thermal output ......................................5,0 / 5,0 kW
Waste air mass ow rate .................................. 3,76 / 3,67 g/s
Waste air temperature at
connection duct .....................................................328 / 286 °C
Minimum delivery pressure at
nominal thermal output ...........................................12 / 11 Pa
Combustion air supply
The stove can be operated conventionally, dependent on
the ambient air as well as independent of the ambient air.
It must be guaranteed that there is enough combustion air
available for the stove. For the proper function of the stove,
a necessary combustion air volume current of 10,5m³/h
must be considered.
Ambient air independent
combustion air connection
By an ambient air independent operating mode, the com-
bustion air must be added from outside through a leak-
proof line or through a supply duct in the chimney. Thus,
speak with your district chimney sweep master.
Due to energy saving reasons, the combustion air inlet
should be able to be blocked if the stove is not being op-
erated. This can occur through a shut-o valve in the com-
bustion air line or through the air slide valves on the stove.
If a shut-o valve is used, this must be clearly identied
with CLOSED/OPEN.
Through the shuto, it is avoided that heat is removed
from the set-up room through the constant circulation of
cold combustion air and cold combustion air lines may
lead to an increased formation of condensation.
Attention:
The combustion air line may not be closed during
operation!
In order to feed the combustion air to the stove externally
via a pipe instead of from the room in which it is installed,
it is possible to screw a Ø 125 mm combustion air pipe to
the back of the stove or at the bottom. If the combustion
air pipe installed is longer than 3 m, calculations will have
to be carried out to verify an adequate supply of combus-
tion air. At extremely low outdoor temperatures, conden-
sation can occur on the combustion air duct. For this rea-
son it must be insulated with a suitable insulating materi-
al. Observe the rules of the oven and air heating construc-
tion craft.
Use the Olsberg combustion air pipes with sealing lip.
14

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Olsberg Pular Plus Compact wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info