Low b attery indi cator
When th e low battery indicator ap pears on the di splay,
immedia tely replace the ba ttery with a new CR 2032
battery.
NOTES:
• Do not remove the battery arou nd 12:00AM. The
measuremen t results o f the day when the bat tery was
remove d will be adde d to the me asurement results for the
day th e batt ery was inse rted.
(It is assumed th at the ba ttery w ill be remo ved and
replace d with a new one on th e same day .)
• The measu rem ent re sults are a utoma tica lly sto red in
memo ry on t he hour (e.g. at 12:00 AM, 1 :00AM,
2:00A M, ... 9:00PM, 10:00PM , 11:00PM).
The measu rement resul ts from t he hour unt il the ti me the
battery is r eplaced will be delet ed for that day .
• Wh en the batt ery is remove d, the ti me will be reset to
“12:0 0AM”. Re set th e time after i nserti ng the new
battery . Refer to “SETTINGS”.
(Th e mea surem ent re sults stor ed in memo ry and the
weight, height and st ride l ength se ttings are n ot dele ted.)
1. To unlock the bat tery cover mo ve the lock to the
left. Th en pull the cover off by pull ing it awa y from
the unit.
2. Remove the b attery with a toothpick.
NOTE:
Do not use any type of metal objec t to remove the
batt ery.
CAUTION
Dispose of the device, batte ry, and compone nts
according to ap plicable local reg ulations. Unlawf ul
disposa l may cause envi ronment al pollu tion.
CAUTION
Do not thr ow the ba ttery int o fire. T he batte ry may
explode.
3. Insert the battery (CR2032) with the positive (+)
side face up.
4. Replace the batter y cover by sliding the catch in
first, t hen press down on the ba ttery cover firmly
so it is clo ses. Once t his is comple te, slide th e lock
to the rig ht.
Follow th e procedur e belo w to de lete all the pre vious
measure ment result s and setti ngs, including th e time,
weight, height , and stride leng th.
1. Press and hold an d at the s ame time.
“lb” or “kg” flas hes on t he display .
2. Press a nd hold and at the same time again.
After “Clr” h as been di splayed, “ lb” and “ kg” flash on
the displa y.
The meas urem ent res ults store d in mem ory an d the
settings for the time, weight, height and stride length
are deleted. To conti nue usin g the unit, reset time,
weight, heigh t, and stride length ( refer to
“SETTINGS”).
To keep the unit in the best conditio n and protect the unit
from damage follow the direc tions liste d below:
CAUTION
Do not disasse mble or modify the unit.
Changes or modif ications not appr oved by Omron
Health care will voi d the user warranty.
Clean the unit wit h a soft dry cloth.
Do not use any abrasi ve or volatile
clea ner s.
Do not i mmerse the un it or any o f the
component s in water.
The unit is not wate rproof. Do not
wash it or touch it with wet ha nds. Be care ful that water
does not get into the unit.
Store the uni t in a safe and dry loca tion.
Avoid the unit being e xposed t o direct sunlight , high
temperatur es, high humidi ty, water and/o r dust.
Do not subje ct the unit to strong s hock, drop, or step on
it.
Replace a worn battery with a new one immediately.
Remove the batt ery if the unit will not be used for three
months or longer .
Use of the unit must be consis tent with th e instructi ons
provid ed in this manual.
NOTE:
If a malfunctio n has occurred and you need to repair your
unit, all sett ings and m easurem ent resu lts are de leted. We
recomm end that you record mea surement resul ts.
• Spe cifications a re s ubject to change wi thout notice.
* New battery life base d on OMRON testing.
NOTE:
POTENTIAL FOR RADIO/TELEVISION
INTERFERENCE (for U.S.A. only)
This product ha s been test ed and found to c omply with the
limits for a Cla ss B digital dev ice, pursuant to part 15 of the
FCC rule s.
These limi ts are de signed to provide reasonab le protecti on
agai nst harm ful interfe rence i n a reside ntial instal lation.
The product gene rates, uses, and can radiate radio
frequency e nergy and , if not install ed and used in
accordan ce with the instructi ons, may cause harmfu l
interfer ence to radio comm unicati ons.
However, t here is no guarantee t hat interf erence will n ot
occur in a pa rticular instal lation. I f the product does cause
harmful i nterferenc e to radio or te levision re ception, whi ch
can be determin ed by turning the pr oduct o n and of f, the
user is encour aged to tr y to cor rect the interference by one
or more of th e foll owing me asures:
• Reorient or relo cate the receivi ng antenna.
• Incr ease the separa tion betwee n the product an d the
rece iver.
• Conne ct the produc t into an outle t on a circui t different
from that to whi ch the receiver is connected.
• Consult t he dealer or an experienced radio/TV tech nician
for help.
Changes or modif ications not expressly a pproved by the
party responsi ble for com pliance cou ld void the user’s
authority to ope rate the equipment.
Your OMRON HJ-325 Pedo meter, excludin g the battery, is
warrante d to be fre e from def ects in mat erials a nd
workmanshi p appearin g withi n 1 year from t he date of
purchas e, when used in accordanc e with the instruct ions
provided with t he unit. The abov e warrant ies ex tend onl y to
the or iginal re tail purch aser.
We will, at o ur option, repair or re place witho ut charge any
Pedomet er covered by the above warranties . Repair or
replacem ent is our only resp onsibil ity and your only
remedy und er the above warr anties.
To obtain warranty service conta ct Omron’s Cust omer
Support at 1-80 0-634-4350. Infor mation for warran ty
service is available on our website at
www.omronhealthcare.com.
Enclose the Proof of Purchase . Include a lette r, with your
name, address , phone number , and descript ion of the
specific problem. Pack the product carefully to pre vent
damage in tr ansit. Becaus e of possibl e loss in tr ansit, we
recomm end insuring the product wit h return recei pt
requested .
THE FOREGOING IS T HE SOLE W ARRANTY
PROVIDED BY OMRON IN CONNECTION WITH
THIS PRODUCT, AND O MRON HEREBY DISC LAIMS
ANY OTHER WARRANTIES, EXPRESS OR IMPLIED,
INCLUDING IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE. IMPLIED WAR RANTIES
AND OTHER TERMS THAT MAY BE IMPOSED BY
LAW, IF ANY, ARE LIMITED IN DURATION T O THE
PERIOD OF THE A BOVE EXPRESS WARRANTY.
OMRON SHALL NOT BE LIABLE FOR LOSS OF USE
OR ANY OTH ER SPECIAL, INCIDENTAL,
CONSEQUENTIAL OR INDIR ECT COSTS, EXPENSES
OR DAMAGES.
This warranty provides you with spe cific legal rights , and
you may hav e other rights tha t vary by jurisd iction. B ecause
of special lo cal requir ements, some of the a bove limit ations
and exclusi ons may not apply to yo u.
FOR C UST OMER SER VIC E
Visit our web site at: www.omronhealthcare .com
Call toll free : 1-800-634- 4350
DISTRIBUTED BY:
OMRON HEALTHCARE, INC.
1925 West Fiel d Court
Lake Forest , IL 6 0045 U.S.A.
www.omronhealthcare.com
© 2014 OMRON HEALTHCARE, INC.
Made in China
BATTERY LI FE
Blinking Battery power is low.
Appears
continuously
Battery power e xhausted.
The unit stops measurement.
BATTERY REPLACEMENT
DELETI NG ALL RESU LTS AND SETTINGS
CARE AND MA INTENANCE
TROUBLES HOOTING TI PS
Probl em Probable Caus e How to Correct
The low battery
indicator blinks or
appears continuously.
The battery i s low or
worn.
Replace the battery
with a new one
(CR2032), refer to
“BAT TERY
REPL ACE MENT”.
Nothing is displayed.
Battery saving mode
active.
Pres s eit her of ,
or , refer t o
“The battery saving
mode” in “READING
THE CU RRENT
DISPLAY”.
The polarities of the
battery (+ and -) are
aligned in the wrong
directions.
Insert the ba ttery in
correct alignement,
refer to “BATT ERY
REPL ACE MENT”.
The battery is worn.
Replace the battery
with a new one
(CR2032), refer to
“BAT TERY
REPL ACE MENT”.
The displayed values
are incorrect .
The unit is
positioned
incorrectly.
Refer to “ The unit may
not count steps
correctly in the
following conditions:”
in “USING THE
UNIT”.
Irregular movement.
Inconsistent pace.
Up and down
movement.
The set values are
wrong.
Check the settings,
refer to “SETT INGS”.
The display is unus ual or the buttons do not
operate normally.
Replace the battery
with a new one
(CR2032), refer to
“BAT TERY
REPL ACE MENT”.
Device error.
Reinstall the ba ttery,
refer to “BATT ERY
REPL ACE MENT”.
SPECIFICATIONS
Model: HJ-325
Product Name Alvita Ultimate
Power Supply: 3VDC (1 lithium battery CR2032)
Measurement
Range:
Steps: 0 to 99,999 steps
Distance: 0.0 to 621.3 mil es /
0.0 to 999.9 km
Calories: 0 to 59,999 kcal
Aerobic steps: 0 to 99,999 steps
Time: 12:00AM to 11:59PM
Memor y: Previous 7 days on display
Setting Range: Time: 12:00AM to 11:59PM
Weight: 66 to 300 lb (in increments
of 1 lb) / 30 to 136 kg (in
increments of 1 kg)
Height: 3'4'' to 6 '6'' (in increments of
1 inch) / 100 to 199 cm (in
increments of 1 cm)
Stride length: 12" to 48" (in increments of
1 inch) / 30 to 120 cm (in
increments of 1 cm)
Operating
Temperature/
Humidity:
14°F to 104°F (-10°C to + 40°C) / 30% to 85% RH
Battery Life: Approx. 6 months* (when us ed for 14 hours a day)
NOTE:
The supplied battery is f or initial use. This battery
can run out within 6 months.
Exter nal
Dimensions:
Approx. 1.65"(w) × 2.24"(h) × 0.51"(d)
(42.0(W) × 57.0(H) × 13.0(D) mm)
Weight: Approx. 0.8 oz / 23 g (battery included)
Contents: Pedometer, Holder, Battery (CR2032 installed),
Strap, Clip and I nstruction manual
FCC STAT EMENT
LIMITED WARRANTY