Congratulaons! You have successfully installed the security system!
C
Need customer support? Please call us at 1-888-212-2254
or email at Support@OplinkSecurity.com
A
STEP
2
• Set up an account with your smartphone
Launch the “Oplink mi Security” applicaon. Follow the instrucons on the applicaon page to
acvate your account using your phone number.
STEP
9
• Acvaon completed
When you see the “System is ready!” message, your system is ready for use.
Note: Your IP Camera status will be updated aer 10 minutes.
STEP
6
For complete user manuals and installaon videos, please visit
www.OplinkSecurity.com
Package Contents (for indoor use only)
PT IP Camera
Add on Devices
View more on our webstore
RF RepeaterWiFi Smart Plug
Panic Button
Remote Control (2)
Window Decal (3)
* Trigger the Panic Alarm feature
by pressing the Arm buon for
3 seconds
STEP
1
• Download the Oplink App
Android: Open Google Play Store. Search for “Oplink mi Security” and install the applicaon.
iPhone: Open App Store. Search for “Oplink mi Security” and install the applicaon.
Windows: Open Marketplace. Search for “Oplink” and install the applicaon.
2013 Oplink Communicaons, Inc. All rights reserved.
For the latest version of
Oplink Terms and Condions,
please visit our website.
99200090MIG001
STEP
4
• Power up the IP Camera
Plug the IP Camera into an outlet within 5 feet of the OPU to establish connecon. Once
connecon is established and working, the IP camera can be moved to its desired locaon.
STEP
4
(E)
(F)
The camera can be moved
and mounted aer the
inial acvaon.
Note: Should the placement of the camera cause the image to be upside-down, use the Flip
feature in the App to correct this maer. Video > Single Video Mode > Image Seng
(I) Siren with Power Adapter (1)
Double-sided Tape (1)
Mounng Screws (2)
Screw Anchors (2)
STEP
8
(I)
STEP
3
internet
(B)
(C)
(A)
(D)
• Assemble the OPU staon and connect to a router
Assemble the system according to the provided picture. It is recommended that the OPU be
placed on a 3-5 (0.91-1.52m) high plaorm.
Note: Once the OPU is up and running, to establish proper connecon to it, power up the remaining devices within 5 feet of
the OPU. When connecon is established and working, the devices can be moved to their desired locaons.
TripleShield™
STEP
7
Setup GuideB
STEP
5
(Sample QR Code)
Note: When the acvaon
process cannot be completed
normally, the App will ask you
to scan the OPU’s QR code,
located on the back of the
OPU, to connue.
• Start device acvaon on the App
Tap the “Acvate Now” buon.
(Acvaon process takes approximately 2 minutes)
• Power up the Siren
Plug the Siren into an outlet within 5 feet of the OPU to establish connecon. Once connecon
is established and working, the Siren can be moved to its desired locaon. Your Siren comes with
a backup baery pre-installed. To make use of the backup baery, pull and remove the clear
plasc strip to iniate baery contact.
Magnet
Spacer
Sensor
STEP
8
Router
(not included)
• Install Door/Window Sensor baeries
Each Door/Window Sensor set consists of two pieces. Take the larger piece and with slight force,
push the small tab on the back plate outward and slide the back plate upward. Remove the back
plate and insert a baery into each Door/Window Sensor set. Apply the double-sided tape to each
piece. It is recommended that the Door/Window Sensor be mounted in a vercal/upright posion.
1/4 inch Max
Mount Door Sensor
Note: For the Door/Window Sensor, it does not maer which piece you
place on the frame and which piece you place onthe moving part.
To create proper contact, ensure the tops of the two pieces line up.
The Spacer is used in situaons where the smaller piece needs to be
elevated to the larger piece to ensure proper contact.
Mount Window Sensor
(G) Door/Window Sensor
Baery Installaon
(H) Moon Sensor
Baery Installaon
• Place the Moon Sensor
Li the top tab to remove the cover and install the baery into the Moon Sensor. For maximum
coverage, the sensor should be placed in the corner of the room to be monitored and no more
than 7 feet above the ground. The Moon Sensor is most effecve in areas such as hallways and
entry points where possible intruders will have to pass through.
Mount Moon Sensor
(D) OPU Power Adapter (1)
STEP
6
Inactivity Sensor
Brauchen Sie Hilfe? Stellen Sie Ihre Frage.
Missbrauch melden von Frage und/oder Antwort
Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.
Art des Missbrauchs:
Forenregeln
Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:
Lesen Sie zuerst die Anleitung;
Schauen Sie nach, ob die Frage bereits gestellt wurde;
Stellen Sie die Frage so deutlich wie nur einigermaßen möglich;
Erwähnen Sie was Sie bereits versucht haben um das Problem zu lösen;
Ist Ihr Problem von einem Besucher gelöst dann lassen Sie ihn / sie wissen in diesem Forum;
Falls Sie reagieren möchten, so verwenden Sie bitte das Antworten- Formular;
Da ihre Frage für alle Besucher sichtbar ist, sollten Sie lieber keine persönliche Daten erwähnen.
Neu registrieren
Registrieren auf E - Mails für Oplink TripleShield wenn:
neue Frage gestellt werden
neue Handbücher vorhanden sind
Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.
Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.
Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.
Ihre Frage wurde zu diesem Forum hinzugefügt
Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.