3.9. Multiple Unit
The HQView-510/520/530 have a Multiple Unit menu to set up each unit for use in a multi screen
application.
Multiple screens are stitched together to provide a bigger display with higher resolution than a single
display. Each display is driven by a separate HQView unit. Each HQView unit gets the same graphics
or video input signal through a distribution amplifier. The HQView unit cuts out and resizes the image
to display the part of the image assigned to the corresponding screen. In a multi projection display the
individual projections typically are chosen to overlap to give seamless transitions. Overlapping regions
are illuminated by multiple projectors and are brighter than non-overlapping regions. For a uniform
brightness over the total display the brightness in the overlapping regions has to be reduced
electronically. PiP functionality is not supported due to higher bandwidth requirements of the video
processing.
Important: When using multiple HQView units to drive one single large screen, it is essential that all
HQView units are I/O locked, otherwise motion tear will be observed at the boundaries of the image
processed by each HQView unit. It is also essential that all HQView units are setup for the same
processing latency (either all units are in Best Picture mode or all units are in Low Latency mode).
3.9.1. Auto Zoom
Settings: On, Off
Switches on the auto zoom resizing the video image to display the assigned part of the total image.
AutoZoom is switched off automatically when the on-screen menu is activated and that menu cannot
be properly displayed. The menu is scaled to a certain extend by the warp engine and may exceed the
size of the screen. Also, only the active video area can be used for the on-screen menu. This would
crop the menu and make it impossible to navigate. A message will indicate such situations. After
having done the change AutoZoom can be reactivated.
3.9.2. Units Wide/Units High
Settings: 1, 2, 3, 4/ 1, 2, 3, 4
Provides the HQView unit information of the multi screen installation. The number of horizontally and
vertically installed screens or projectors is entered.
3.9.3. Horizontal Pos/Vertical Pos
Settings: 0 to (Units Wide 1) in steps of 1/ 0 to (Units High 1) in steps of 1
Provides the HQView unit information which window of the total image it is assigned to and has to
process (cut out and resize).
3.9.4. Blend Width
The blend width menu provides sliders to set up the overlap region for left, right, top and bottom blend
region. When changing the slider value from within the OSD the blend area is not update immediately.
An update is forced when pressing the menu button, thus the slider is replaced by the menu. This is
not ideal, but excessive blend area write time suggested this approach.
The overlap is set up in output pixels with a range of up to a quarter of the output resolution. For a
configuration with two projectors in horizontal direction the overlap can be higher to allow 16:9 images
to fit on two combined projectors with an aspect ratio of 4:3 or 5:4.
26

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Optoma HQView-500 Series wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info