ADVANCED PROGRAMMING (SPECIAL FUNCTIONS) EXTRAS
WINTER / SUMMER OFFICIAL TIME CHANGE
Enter in MENU with key OK, use keys
and to select EXTRAS. Validate with
OK and display shows EXTRAS SEASON, press again OK and it is shown
SEASON:ON, with keys
and it is possible to select three options: AUTO,
MANUAL and NOT USE; validate always with OK.
AUTO: (The clock is automatically changed on the last Sunday in March and the
last Sunday in October at 2:00 h and at 3:00 h respectively). This option does not
allow any change.
MANUAL: (Allows to choose the date and time for the time change). When
selecting this option display shows SEA W-S, the month and the time for Winter to
Summer change, using keys
and it is possible to change the month for the
automatic change, validate with OK and change, in the same way, the day, hour
and minutes, finally validate with OK. Then it appears SEA S-W and proceed in the
same way.
DEACTIVATED (NOT USE): (No time change will be made)
If this option is selected, no automatic time change will be executed. If there is any
switching programmed at the exact time of the time change period, these will be
duplicated or not executed, depending the type of time change.
PROGRAMMING FESTIVITY PERIODS
This menu only appears if any switching has been programmed in MENU
PROGRAMMING as FESTIVITY. Only one period of FESTIVITY can be
programmed. Enter in MENU EXTRAS HOLIDAYS and display shows HOLIDAYS
NOT USE, this option allows to deactivate the holidays programm.
To enter a festivity programm, use keys
and to show in display HOLIDAYS
EDIT, validate with OK and programm the BEGIN as follows: month, day, hour and
minute. Then programm END of the period of festivity in the same way.
During this period, the device will execute the switchnig programmed as festivity,
and display shows the symbol “ “.
HOLIDAY PROGRAM
Enter in MENU EXTRAS HOLIDAYS and the display shows HOLIDAYS NOT USE,
this option allows to deactivate the holidays programm. To enter a holiday
programm press
and and display shows HOLIDAYS EDIT, validate with OK
and programm the BEGIN as follows: month, day, hour and minute. Then
programm END of the period of holidays in the same way.
During this period, the device will not execute any programmed switching, and
display shows the symbol “ “.
IMPORTANT: If any switching is programmed as FESTIVITY, then the
programm HOLIDAYS cannot be used and it is removed from menu
remaining as FESTIVITY period.
COUNTER
Enter in MENU EXTRAS COUNTER, then it appears COUNTER C1: and the
number of hours that circuit C1 has been activated (position ON); using keys
and we can see the counter of circuit C2. Counters only increment the hours if
connected to power supply.
To reset the counters, just press OK when the display shows the counter to see
ERASE C1 or ERASE C2, and select YES with keys
and and then validate
with OK.
MODE 12H – 24H.
Enter in MENU EXTRAS 12H – 24H, press OK and select the mode to display the
time. Validate with OK.
DISPLAY CONTRAST
Enter in MENU EXTRAS CONTRAST, press OK and the display shows
CONTRAST and a number from 0 to 9. Select the desired contrast level by using
keys
and and validate with OK.
TECHINCAL FEATURES
Power supply As indicated on the device
Switching capacity: 16 (10) A / 250 V~
Maximum recommended loads:
Incandescent lamps: 3000 W
Uncompensated fluorescent lamps 1200 W
Compensated fluorescent lamps 1200 W 150 µF
Low voltage halogen lamps 1000 VA
Halogens (230 V) 2500 W
Low-consumption lamps 10X23 W
Contact type and material Changeover AgSnO
2
Power consumption: 6 VA 1 circuit (aprox. 1 W)
Action type: 1B, 1S, 1T and 1U
Memory spaces: 22
Type of switchings: ON
OFF
ASTRONOMIC
Switching accuracy: Better than 1 second
Operating accuracy: ± 1 s/ day at 23 ºC
Power reserve: 4 years (Lithium battery)
at 23 ºC
Operating temperature: - 10 ºC to + 45 ºC
Protection category: IP 20 according to EN 60529
Protection class: II according to EN 60335
when mounted as intended
Pollution situation: Normal
Sealable cover
DIMENSIONS
If you need more information regarding sunrise and sunset times, you can visit the
following websites.
Only for Spain:
http://www.mfom.es/ign/home/astronomia/publico/efemerides/salidasypuestasdesol.html
International:
www.sunrisesunset.com
www.worldtime.org
A016.26.52842
ORBIS TECNOLOGÍA ELÉCTRICA, S.A.
Lérida, 61 E-28020 MADRID
Tel.: + 34 91 567 22 77 Fax + 34 91 571 40 06
E-mail: info@orbis.es
http://www.orbis.es
35
88 45
60
65
2

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Orbis Astro Log wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info