3. Set the channel. The switch is located in the battery
compartment.
4. Place the sensor near the main unit. Press RESET
on the sensor. Then, press and hold MEM and
CHANNEL on the main unit to initiate signal sending
between the sensor and the main unit. The reception
icon on the main unit will blink for approximately 3
minutes while it is searching for the sensor. (Refer to
the "Sensor Data Transmission" section for more
information.)
5. Close the remote sensor battery compartment.
6. Secure the sensor in the desired location using the
wall mount or table stand.
For best results:
•Insert the batteries and select the channel before
you mount the sensor.
•Place the sensor out of direct sunlight and moisture.
Do not place the sensor more than 30 metres
(98 feet) from the main (indoor) unit.
Position the sensor so that it faces the main
(indoor) unit, minimizing obstructions such as
doors, walls, and furniture.
•Place the sensor in a location with a clear view to
the sky, away from metallic or electronic objects.
Position the sensor close to the main unit during
cold winter months as below-freezing temperatures
may affect battery performance and signal
transmission.
You may need to experiment with various locations to
get the best results.
DATA TRANSMISSION
Data is sent from the sensor(s) every 40 seconds. The
reception icon shown in the Temperature and Humidity
Areas show the status.
SEARCH FOR SENSOR
To search for a sensor, press and hold MEM and
CHANNEL (on the main unit) for 2 seconds.
NOTE If the sensor is still not found, check the batteries,
obstructions, and remote unit location.
NOTE Signals from household devices such as doorbells,
electronic garage doors, and home security systems
may cause temporary reception failure. This is normal
and does not affect general product performance. The
reception will resume once the interference ends.
CLOCK
The clock automatically synchronizes the current time
and date when it is brought within range of the radio
signal DCF77 generated from Frankfurt, Germany for
Central Europe (model BAR628HG) or MSF60 generated
from Rugby, England (model BAR628HGU).
NOTE The signals are collected by the main unit when
it is within 1500 km (932 miles) of a signal.
Initial reception takes 2-10 minutes, and is initiated when
you first setup the unit, and whenever you press RESET.
Once complete, the reception icon will stop blinking. The
icon is shown in the Clock Area.
To force a manual search for clock signals, press and
hold
for 2 seconds. If no signal is found, check the
batteries.
TURN CLOCK ON / OFF
Perform this step if you cannot receive clock signals.
Press and hold
for 2 seconds. Then, manually set the
clock following the “Set Clock” instructions (below).
The signal icon indicates that the clock feature is ON.
No icon means that it is OFF.
SET CLOCK / CALENDAR
You only need to do this if you have disabled the clock
feature (for example, if you are too far from or cannot
receive a signal).
1. Press and hold MODE for 2 seconds. The Clock Area
will blink.
2. Select the hour, minute, year, month, day, and day of
the week language. Press
or to change the
setting.
3. Press MODE to confirm.
The language options are (E) English, (F) French, (D)
German, (I) Italian, and (S) Spanish.
Strong signal Weak signal No signal
ICON DESCRIPTION
Main unit is searching for
sensons.
At least 1 channel has been
found.
Channel 1 is selected (number
will change depending on the
sensor you select)
...shows in Outdoor The selected sensor cannot
Temp / Humidity Area be found. Search for the
sensor or check batteries.
5

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Oregon Scientific BAR628HGU wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Oregon Scientific BAR628HGU

Oregon Scientific BAR628HGU Bedienungsanleitung - Deutsch - 9 seiten

Oregon Scientific BAR628HGU Bedienungsanleitung - Holländisch - 10 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info