NOTE The indoor memory record will be cleared
simultaneously.
ICE WARNING
If the channel 1 sensor falls between 3°C to -2°C (37°F
to 28°F),
will flash to warn you that the temperature
is approaching freezing.
NOTE The alarm will automatically stop if the
temperature goes outside the ice-warning range.
RADIO
You can save up to 16 radio stations (8 for AM and 8
for FM).
To turn the radio ON / OFF
:
Press RADIO.
To save a station
:
1. Press
RADIO to turn the radio ON.
2. Press
AM / FM to select radio frequency.
3. Press TUNNING / SET
/ to manually fine
tune the frequency or press and hold TUNNING /
SET / to activate auto-search.
4. Press and hold STATION
to save the station.
SLEEP TIMER
To turn the sleep timer ON:
1. Press
SLEEP once to activate the last setting
used.
2. Press SLEEP to set radio sleep timer duration (120,
90, 60, 30, 15 or 0 minutes). Select “0” to disable
the sleep timer.
3. Press VOLUME / to change the volume.
NOTE “SLEEP” flashes when the sleep timer is
activated.
BACKLIGHT
Press any key to activate the backlight for 1 minute.
RESET
Press RESET to return the main unit to the default
settings. Remove and then re-insert the batteries to
reset the sensor.
PRECAUTIONS
This product is engineered to give you years of
satisfactory service if you handle it carefully. Here are
a few precautions:
Do not use a damp cloth to clean the surface of
the light touch key, If it is necessary to use a damp
cloth to clean the unit, turn the power off before
cleaning.
Placement of this product on wood surfaces with
certain types of finishes, such as clear varnish, may
result in damage to the finish. Consult the furniture
manufacturer’s care instructions for direction as
to the types of wood surface. Oregon Scientific
shall not be responsible for any damage to wood
surfaces from contact with this product.
Do not immerse the unit in water. If you spill liquid
over it, dry it immediately with a soft, lint-free cloth.
Do not clean the unit with abrasive or corrosive
materials.
Do not subject the unit to excessive force, shock,
dust, temperature or humidity, which may result in
malfunction, shorter electronic life span, damaged
battery and distorted parts.
Do not tamper with the unit’s internal components.
Doing so will invalidate the warranty on the unit and
may cause unnecessary damage. The unit contains
no user-serviceable parts.
Only use fresh batteries as specified in the user’s
instructions. Do not mix new and old batteries.
Do not use rechargeable batteries.
Remove batteries when storing the product for a
long time.
Do not dispose this product as unsorted municipal
waste. Collection of such waste separately for
special treatment is necessary.
Due to printing limitations, the displays shown in
this manual may differ from the actual display.
The contents of this manual may not be reproduced
without the permission of the manufacturer.
NOTE The technical specifications for this product and
the contents of the user manual are subject to change
without notice.
SPECIFICATIONS
TYPE DESCRIPTION
Main unit
Dimensions 163 x 65.4 x 96 mm
(L x W x D) (6.4 x 2.6 x 3.8 inches)
Weight 300g (10.6 ounces)
Temperature unit – °C / °F
Indoor range -5°C to 50°C (23°F to 122°F)
Outdoor range -30°C to 60°C (-22°F to 140°F)
Resolution 0.17°C (0.2°F)
Radio clock
Synchronization Auto or disabled
Clock display HH:MM
Hour format 12hr AM/PM or 24hr
Calendar DD/MM or MM/DD
Weekday in 5 (E, G, F, I, S)
languages
Alarm 2-minute beep or radio alarm with
8-minute snooze
PLL Radio FM / AM; MHz / KHz; 16 preset
channels
Sleep 120, 90, 60, 30 and 0 mins
Remote unit (THN132N)
Dimensions 92 x 22 x 50 mm
(L x W x D) (3.6 x 0.9 x 2.0 inches)
Weight 46 g (1.62 lbs) without battery
RF frequency 433MHz
Range Up to 30 meters (100 feet) with no
obstructions
Transmission Approx. every 40 seconds
Channel no. 1, 2 or 3
Power
Main unit 6V adapter
Remote unit 1 x UM-3 (AA) 1.5V battery
NOTE We recommend that you use alkaline batteries in
the sensor for longer usage and lithium batteries for use
in temperatures below freezing.
ABOUT OREGON SCIENTIFIC
Visit our website (www.oregonscientific.com) to
learn more about Oregon Scientific products such as
digital cameras; MP3 players; children’s electronic
learning products and games; projection clocks; health
and fitness gear; weather stations; and digital and
conference phones.
The website also includes contact information for our
Customer Care department in case you need to reach
us, as well as frequently asked questions and customer
downloads. We hope you will find all the information you
need on our website, however if you’re in the US and
would like to contact the Oregon Scientific Customer
Care department directly, please visit:
www2.oregonscientific.com/service/default.asp OR call
1-800-853-8883. For international inquiries, please visit:
www2.oregonscientific.com/about/international.asp
FCC STATEMENT
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1)
This device may not cause harmful interference, and
(2) This device must accept any interference received,
including interference that may cause undesired
operation.
WARNING Changes or modifications not expressly
approved by the party responsible for compliance could
void the user’s authority to operate the equipment.
NOTE This equipment has been tested and found
to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against
harmful interference in a residential installation.
This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful
interference to radio communications. However, there
is no guarantee that interference will not occur in a
particular installation. If this equipment does cause
harmful interference to radio or television reception,
which can be determined by turning the equipment
off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment
and receiver.
Connect the equipment into an outlet on a
circuit different from that to which the receiver is
connected.
Consult the dealer or an experienced radio / TV
technician for help.
DECLARATION OF CONFORMITY
The following information is not to be used as contact
for support or sales. Please call our customer service
number (listed on our website at www.oregonscientific.
com), or on the warranty card for this product) for all
inquiries instead.
We
Name: Oregon Scientific, Inc.
Address: 19861 SW 95th Ave., Tualatin,
Oregon 97062 USA
Telephone No.: 1-800-853-8883
declare that the product
Product No.: BARM699A
Product Name: Wireless Thermometer with
Self-Setting Clock and FM
Radio
Manufacturer: IDT Technology Limited
Address: Block C, 9/F, Kaiser Estate,
Phase 1,41 Man Yue St., Hung
Hom, Kowloon, Hong Kong
is in conformity with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: 1)
This device may not cause harmful interference. 2) This
device must accept any interference received, including
interference that may cause undesired operation.
© 2006 Oregon Scientific. All rights reserved.
086L004256-013
BARM699A_EN_R5.indd 2 2/17/06 2:05:00 PM
2

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Oregon Scientific BARM699A wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info