Wireless Indoor and Outdoor
Thermometer with Digital Clock
Model: EMR801
USER MANUAL
OVERVIEW
FRONT VIEW
1
2
3
5
6
7
8
9
4
1. Solar panel
2. Outdoor temperature
3. Indoor temperature / Time
4. Ice alert indicator
5. : Increase value ; auto-toggle of indoor temperature
and time
6. MODE: Enter setting mode; toggle between indoor
temperature and time
7. Main unit low battery indicator
8. Remote sensor low battery indicator
9. Remote sensor reception indicator
BACK VIEW
1
2
3
45
6
1. Wall-mount hole
2. Mounting magnet
3. °C/°F: Select temperature unit
4. Battery compartment
5. Table stand
6. RESET: Reset unit to default settings
REMOTE SENSOR
2
3
4
5
1
1. LED status indicator
2. Wall mount hole
3. Battery compartment
4. RESET hole
5. CHANNEL switch
GETTING STARTED
SOLAR PANEL
The solar panel is an energy saving feature, which is an
environmentally friendly way to provide additional power to
the main unit and prolongs battery life. However, it cannot
replace battery power entirely.
INSERT BATTERIES
1. Remove the battery compartment.
2. Insert the batteries, matching the polarities.
3. Press RESET after each battery change.
LOCATION MEANING
Indoor temperature / time
area
Main unit batteries low
Outdoor temperature area Sensor batteries low
SET CLOCK
1. Press and hold MODE for 2 seconds.
2. Press to change values.
3. Press MODE to confirm.
4. The settings order is: 12/24 hour format, hour and
minute.
REMOTE SENSOR
To set up the sensor:
1. Open the battery compartment and insert the battery,
matching the polarity.
2. Press RESET.
3. Close the battery door.
4. Place the sensor within 30 m (98 ft) of the main
unit using the table stand , mounting magnet or wall
mount.
TIP Ideal placements for the sensor would be in any
location on the exterior of the home at a height of not more
than 1.5 m (5 ft) and which can shield it from direct sunlight
or wet conditions for an accurate reading.
1.5 m (5 ft)
NOTE Use alkaline batteries for longer usage and
consumer grade lithium batteries in temperatures below
freezing.
SENSOR DATA TRANSMISSION
To search for a sensor:
Press and hold MODE + for 2 seconds.
The sensor reception icon in the remote sensor area
shows the status:
ICON DESCRIPTION
OUT OUT
Main unit is searching
for sensor(s).
OUT OUT OUT OUT
A channel has been
found.
OUT
The sensor cannot be
found.
TIP The transmission range may vary depending on
many factors. You may need to experiment with various
locations to get the best results.
TIME AND INDOOR TEMPERATURE DISPLAY
To enable auto-toggle display of time and indoor
temperature:
Press and hold for 2 seconds.
To disable auto-toggle display of time and indoor
temperature:
Press MODE.
To manually toggle between time and indoor
temperature display:
Press MODE.
ICE WARNING
If the sensor falls between 3°C to -2 °C (37°F to 28°F), the
green LED indicator will flash, and will stop flashing once
the temperature is out of this range.
NOTE As ice alert is only applicable to channel 1, to
prevent flashing of LED, select channel 2 or 3 on outdoor
sensor.
RESET
Press RESET to return to the default settings.
PRECAUTIONS
Do not subject the unit to excessive force, shock, dust,
temperature or humidity.
Do not cover the ventilation holes with any items such
as newspapers, curtains etc.
Do not immerse the unit in water. If you spill liquid over
it, dry it immediately with a soft, lint-free cloth.
Do not clean the unit with abrasive or corrosive
materials.
Do not tamper with the unit’s internal components.
This invalidates the warranty.
Only use fresh batteries. Do not mix new and old
batteries.
Images shown in this manual may differ from the
actual display.
When disposing of this product, ensure it is collected
separately for special treatment.
Placement of this product on certain types of wood
may result in damage to its finish for which Oregon
Scientific will not be responsible. Consult the furniture
manufacturer’s care instructions for information.
The contents of this manual may not be reproduced
without the permission of the manufacturer.
Do not dispose old batteries as unsorted municipal
waste. Collection of such waste separately for special
treatment is necessary.
Please note that some units are equipped with a
battery safety strip. Remove the strip from the battery
compartment before first use.
NOTE The technical specifications for this product and
the contents of the user manual are subject to change
without notice.
NOTE Features and accessories will not be available
in all countries. For more information, please contact your
local retailer.
SPECIFICATIONS
TYPE DESCRIPTION
MAIN UNIT
L x W x H 68 x 24 x 96 mm
(2.68 x 0.94 x 3.78 in)
Weight 80 g (2.82 oz) without battery
Temperature range -5°C to 50°C (23°F to 122°F)
Signal frequency 433 MHz
Power 2 x UM-4 (AAA)
1.5 V batteries
REMOTE UNIT (THN132N)
L x W x H 96 x 50 x 22 mm
(3.78 x 1.97 x 0.87 in)
Weight 62 g (2.22 ounces)
Transmission range 30 m (98 ft) unobstructed
Temperature range -20°C to 60°C (-4°F to 140°F)
Power 1 x UM-3 (AA) 1.5 V batteries
ABOUT OREGON SCIENTIFIC
Visit our website (www.oregonscientific.com) to learn
more about Oregon Scientific products. If you’re in the US
and would like to contact our Customer Care department
directly, please visit: www2.oregonscientific.com/service/
support
For international inquiries, please visit:
www2.oregonscientific.com/about/international
FCC STATEMENT
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) This
device must accept any interference received, including
interference that may cause undesired operation.
WARNING Changes or modifications not expressly
approved by the party responsible for compliance could
void the user’s authority to operate the equipment.
NOTE This equipment has been tested and found
to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful
interference in a residential installation.
This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful
interference to radio communications. However, there
is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be
determined by turning the equipment off and on, the user
is encouraged to try to correct the interference by one or
more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and
receiver.
Connect the equipment into an outlet on a circuit
different from that to which the receiver is
connected.
Consult the dealer or an experienced radio / TV
technician for help.
DECLARATION OF CONFORMITY
The following information is not to be used as contact
for support or sales. Please visit our website at www2.
oregonscientific.com/service for all enquiries.
We
Name: Oregon Scientific, Inc.
Address: 19861 SW 95th Ave.,Tualatin,
Oregon 97062 USA
Telephone No.: 1-800-853-8883
declare that the product
Product No.: EMR801
Product Name: Wireless Indoor and Outdoor
Thermometer with Digital Clock
Manufacturer: IDT Technology Limited
Address: Block C, 9/F, Kaiser Estate,
Phase 1,41 Man Yue St.,
Hung Hom, Kowloon,
Hong Kong
is in conformity with Part 15 of the FCC Rules.Operation is
subject to the following two conditions: 1) This device may
not cause harmful interference.2) This device must accept
any interference received, including interference that may
cause undesired operation.
Thermomètre extérieur et intérieur
sans fil à horloge numérique
Modèle : EMR801
Manuel de l’utilisateur
VUE D’ENSEMBLE
FACE AVANT
1. Panneau solaire
2. Température extérieure
3. Température intérieure / heure
4. Indicateur d’alerte du niveau de gel
5. : Augmente la valeur, alternance automatique de
l’heure et de la température intérieure
6. MODE : Permet d’entrer dans le mode Réglages,
d’alterner entre l’heure et la température intérieure
7. Indicateur de faiblesse des piles de l’appareil
principal
8. Indicateur de faiblesse de la pile de la sonde sans fil
9. Indicateur de réception de la sonde sans fil
FACE ARRIERE
1
2
3
45
6
1. Trou de fixation murale
2. Aimant de montage
3. °C / °F : Permet de sélectionner l’unité de mesure de
la température
4. Compartiment des piles
5. Support de table
6. RESET (REINITIALISER) : Réinitialise l’appareil aux
réglages par défaut
SONDE SANS FIL
2
3
4
5
1
1. Indicateur de statut LED
2. Trou de fixation murale
3. Compartiment des piles
4. Fente RESET (Réinitialiser)
5. Bouton CHANNEL (CANAL)
1

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Oregon Scientific EMR801 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info