2. Rotate the dial left or right to set the desired values.
3. Press
ALARM to confirm the settings.
To activate / deactivate the high UV alarm:
1. In the UV / Barometer / Rainfall Area and UVI reading
display, press ALARM repeatedly to select the
desired alarm.
2. Press MEMORY / ON / OFF to activate or
deactivate the alarm.
BAROMETER
To change the barometer alarm:
1. In the UV / Barometer / Rainfall Area and
Barometer
reading display, press and hold ALARM to enter the
Barometer alarm setting.
2. Rotate the dial left or right to set the desired values.
3. Press
ALARM to confirm the settings.
To activate / deactivate the
barometer alarm:
1. In the UV / Barometer / Rainfall Area and Barometer
reading display, press
ALARM repeatedly to select
the desired alarm.
2. Press MEMORY /
ON / OFF to activate or
deactivate the alarm.
To set the altitude level compensation for the
Barometer readings:
1. In the UV / Barometer / Rainfall Area and Barometer
reading display. Press and hold
MODE to enter the
altitude setting.
2. Rotate the dial left or right to set the desired values.
3. Press
MODE to confirm the setting.
RAINFALL
To view the current hour, accumulated or last 24
hours rainfall history:
In the UV / Barometer / Rainfall Area and Rainfall reading
display, press
MEMORY / ON / OFF repeatedly to
toggle between current, past 24 hours or accumulated
rainfall. The clock line will change to display the start
time when the accumulated rainfall is displayed. The icon
appears and the start date is showing.
To toggle between rainfall & rain rate display:
In the UV / Barometer / Rainfall Area and Rainfall reading
display, press and hold
MODE.
To reset the accumulated rainfall and timestamp:
In the UV / Barometer / Rainfall Area and Rainfall reading
display
. Press and hold MEMORY / ON / OFF to reset
the accumulated rainfall to ‘0’ and to set the timestamp
to current date and time.
To change the HI rainfall rate alarm:
1. In the UV / Barometer / Rainfall Area and Rainfall
reading display, press and hold
ALARM to enter the
Rainfall alarm setting.
2. Rotate the dial left or right to set the desired values.
3. Press ALARM to confirm the settings.
To activate / deactivate the HI rainfall rate
alarm:
1. In the UV / Barometer / Rainfall Area and Rainfall
reading display, press
ALARM repeatedly to select
the desired alarm.
2. Press MEMORY / ON / OFF to activate or
deactivate the alarm.
WEATHER ALARMS
Weather alarms are used to alert you of certain weather
conditions. Once activated, the alarm will go off when a
certain criterion is met.
Alarms can be set for:
Indoor and outdoor high / low temperatures, dew point
and High / Low humidity
High Heat Index
High Gust Wind
Low wind chill
High UV
Pressure drop
High rain rate
See the relevant section for how to set the alarm.
To silence any alarm: Press any button or rotate the
dial.
SET UP SOFTWARE (FIRST TIME USE)
The main unit is capable of connecting to a PC computer
using the USB connection. The software can read the
latest weather data collected from the base station.
PC system requirements
The minimum system requirements for use of the
software is:
Operating system: Microsoft Windows XP SP2 or
Vista
Processor: Pentium 4 or above
RAM: Min. 512MB
Hard disk free space: Min. 512MB
S cr e e n D isp l a y Ar e a : 1 0 2 4 x 7 6 8 p i x e l s
(recommended)
WINDOWS XP
To install software:
1. Run CD software provided.
2. Setup wizard dialogue box will appear and guide you
through the installation process.
3. After successful installation, double click on
desktop shortcut.
4. Click DISPLAY in Oregon Weather Station dialogue
box.
WINDOWS VISTA
To Disable User Access Control (UAC):
1. From the desktop, My Computer > Control Panel >
14

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Oregon Scientific WMR100NA wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Oregon Scientific WMR100NA

Oregon Scientific WMR100NA Bedienungsanleitung - Deutsch - 18 seiten

Oregon Scientific WMR100NA Bedienungsanleitung - Holländisch - 17 seiten

Oregon Scientific WMR100NA Bedienungsanleitung - Französisch - 18 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info