GB
To clear the memory,
1. Press the outdoor/channel humidity window.
2. Press [CHANNEL] for the outdoor thermo-hygrometer or the
desired channel.
3. Press and hold [MEMORY] till a key tone is heard.
4. Press [MEMORY] to check if the memory is clear.
AUTO SCANNING FUNCTION
The auto scanning function is avalibable for the outdoor/channel
window for both the temperature and humidity.
To use it,
1. Press the outdoor/channel temperature or humidity window.
2. Press and hold [
] until another key tone is heard. The main
unit will start scanning from the active temperature and humidity
display. Each channel will be displayed for about 4 seconds.
To exit the auto scanning routine, press any window or control
button.
RAINFALL
The rate of rainfall can be displayed in mm/hr or in/hr.
To select the display unit,
1. Press the rainfall window.
2. Press [UNIT] for the desired setting.
To display the yesterday’s rainfall and the total rainfall from the
last cleared date,
1. Press the rainfall window.
2. Press [MEMORY] for the desired record. Yesterday rainfall will
be displayed with “YESTERDAY” shown in the rainfall window.
Total rainfall will be displayed with "TOTAL" shown in the
rainfall window. The time and date of the record will be displayed
alternatively with “SINCE” icon in the clock window for total
rainfall.
Note: Yesterday’s rainfall record will be updated when the real time
clock runs from 11:59:59 pm to 12:00:00 am. And it is counted for
12:00:00 am of one day to 12:00:00 am on the next day.
If the rain sensor detects no rainfall for about two consecutive
hours, the current rate of rainfall will be displayed as zero.
To clear the total rainfall,
1. Press the rainfall window.
2. Press and hold [MEMORY] till a key tone is heard.
The yesterday’s rainfall record will not be affected when you clear
the total rainfall.
WIND SPEED AND DIRECTION
The current wind speed and direction are displayed in the wind
speed and direction window.
To display the average wind speed, press the window till the
“AVERAGE” icon is displayed.
The wind speed can be displayed in m/s, kph, mph or knots.
To select the display unit,
1. Press the wind speed and direction window.
2. Press [UNIT] for the desired setting.
To display the maximum speed and direction for gust wind in
record,
1. Press the wind speed and direction window.
2. Press [MEMORY]. The time and date of the record will also be
displayed aternatively with “STAMP” icon in the clock window.
To clear the record,
1. Press the wind speed and direction window.
2. Press and hold [MEMORY] till a key tone is heard.
As for the wind direction, it is displayed in a digital compass with
bearing read-outs.
WEATHER ALARMS
Weather alarms are used to alert you to certain weather conditions.
Once activated, the alarm will go off when a certain set of criterion
is met.
You can set alarms for:
Indoor, outdoor and channel high temperatures
Indoor, outdoor and channel low temperatures
Indoor, outdoor and channel dew point approaching
Indoor, outdoor and channel high humidity
Indoor, outdoor and channel low humidity
High rainfall rate
Pressure drop
High gust wind
Low wind chill
To set a weather alarm,
1. Press the window containing the weather element you want to
set.
2. Press [ALARM]. The current alarm setting will be displayed.
3. Press and hold [SET].
4. Press [
] and [ ] for the desired setting.
5. Press [SET].
For temperatures and humidity, the high and low alarms can be set
in sequence. After entering the value for one alarm, you will be
prompted to enter the value for the other.
A weather alarm is activated once set. When the set criteria are met,
an alarm will go off and the current reading will flash together with
the corresponding indicator.
If that happens in the outdoor/channel temperature or humidity
window, the “OUT” indicator will flash to show that the criteria set
for the outdoor thermo-hygrometer have been met. If it is one of the
separate sensors, the [CHANNEL] indicator will flash. Press the
window repeatedly to locate the channel in question.
When a weather alarm goes off, press any button to stop the alarm.
The alarm is still active until you deactivate the function or the
criteria are no longer met.
7

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Oregon Scientific WMR112 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Oregon Scientific WMR112

Oregon Scientific WMR112 Bedienungsanleitung - Deutsch - 10 seiten

Oregon Scientific WMR112 Bedienungsanleitung - Holländisch - 9 seiten

Oregon Scientific WMR112 Bedienungsanleitung - Französisch - 9 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info