RESET
Press and hold and together for 6 seconds to return the device to default
settings.
MAINTAINANCE
Maintain the Rain Gauge
Cleaning the hole of the rain collector and the tipping bucket to maintain accuracy.
Unscrew the tipping bucket and clean the dirt with water periodically.
Maintain the Wind Sensor
If the wind cup doesn’t spin in the wind or does not spin as fast as they should.
Remove the wind cup and clear out all bugs, spider webs or debris.
NOTE Do not apply any uid lubricant on the shaft and bearing. It will break the inner
electronic components.
SPECIFICATIONS
BASE STATION
Dimension (L x W x H) 180 x 90 x 160 mm
(7 x 3.54 x 6.3 inches)
Weight 427.5 g (0.94 lbs) without battery
Battery 3 x 1.5 V AA batteries
AC/DC Adapter Input: 100 – 240 V, 50-60 Hz 300 mA
Output: DC 5V, 1000 mA
ALL-IN-ONE SENSOR
Dimension (L x W x H) 385 x 195 x 315 mm
(15.16 x 7.68 x 12.4 inches)
Weight 1139 g (2.51 lbs) without battery
RF transmission frequency EU: 868mhz, US: 915mhz
No. of channels 3
RF transmission
range
250 – 300 m (internal antenna)
Transmission Cycle 15 seconds
Battery 4 x 1.5 V AA batteries
Battery life 12 months
BAROMETRIC PRESSURE
Unit mb, inHg, mmHg and hPa
Measuring range 700 – 1050 hPa
Accuracy +/- 7 hP a
Altitude setting Sea level
User setting for offset pressure to sea level
Weather display Sunny, Partly Cloudy, Cloudy,
Rainy and Snowy
INDOOR TEMPERATURE
Temperature unit °C / °F (°C for EU, °F for US)
Measuring Range -5 – 50 °C (23 – 122 °F)
Accuracy 0 – 40 °C (32 – 104 °F): +/-1 °C (+/- 2 °F)
-5 – 0 °C (23 – 32.0 °F): +/-2 °C (+/- 4 °F)
40 – 50 °C (104 – 122 °F): +/-2 °C (+/- 4 °F)
Resolution 0.1 °C (0.2 °F)
Memory Current, Min. and Max.
RELATIVE HUMIDITY
Measuring Range 10 % 95 % RH
Accuracy 40 % 80 % RH: +/-5 % RH
25 % 40 % RH and 80 % 90 % RH: +/-7 % RH
Resolution 1 %
Memory Current, Min and Max
OUTDOOR TEMPERATURE
Temp. unit °C / °F (°C for EU, °F for US)
Measuring Range -30 – 60 °C (-22 to 140 °F)
Accuracy -20 – 0 °C: +/-2.0 °C (+/- 4.0 °F)
0 – 40 °C: +/-1.0 °C (+/- 2.0 °F)
40 – 50 °C: +/-2.0 °C (+/- 4.0 °F)
50 – 60 °C: +/- 3.0 °C (+/- 6.0 °F)
Temperature resolution 0.1°C (0.2 °F)
Memory Current, Min and Max
WIND SENSOR
Wind speed unit m/s, knots, kph, mph
Speed accuracy 2 – 10 m/s (+/-2 m/s)
10 – 56 m/s (+/-10 % m/s)
Direction resolution 22.5 degrees
Memory Max wind speed
RAIN GAUGE
Rainfall unit mm , inch (mm for EU, inch for US)
Rain rate unit mm/hr and inch/hr
Measuring range for rainfall 0 mm to 9999 mm (0 – 393.6 inches)
Measuring range for rain rate 0, 0.04 in/hr (1mm/hr) to
40 in/hr (1016 mm/hr)
Accuracy 0 – 15 mm (0 – 0.6”)/hr : +/-1 mm/hr (0.04”)
15 – 991 mm/hr (0.6 – 39”) : +/-10 %
Memory Past 24 hrs, hourly from last memory reset
PRECAUTIONS
Use only fresh batteries of the required size and type. Do not mix old and new
batteries, different types of batteries.
Do not dispose old batteries as unsorted municipal waste. Collection of such
waste separately for special treatment is necessary.
If you do not plan to use the product for a long time, remove the batteries.
Batteries can leak chemicals that can damage electronic parts.
Do not subject the device to excessive force, shock, dust, temperature or
humidity.
Do not immerse the device in water. If you spill liquid over it, dry it immediately
with a soft, lint-free cloth.
Do not clean the device with abrasive or corrosive materials.
Do not tamper with the device’s internal components. Doing so invalidates the
warranty.
Images shown in this manual may differ from the actual display.
When disposing of this product, ensure it is collected separately for special
treatment.
The contents of this manual may not be reproduced without the permission of the
manufacturer.
NOTE
The technical specications for this product and the contents of the user
manual are subject to change without notice.
NOTE
Features and accessories will not be available in all countries. For more
information, please contact your local retailer. To download an electronic version of
the user manual, please visit http://global.oregonscientic.com/customerSupport.php.
5
7

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Oregon Scientific WMR500 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Oregon Scientific WMR500

Oregon Scientific WMR500 Bedienungsanleitung - Deutsch, Englisch, Holländisch, Französisch, Italienisch, Portugiesisch, Spanisch - 70 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info