5
To select the display unit,
1. Press the indoor temperature window.
2.
Press [UNIT] repeatedly for the desired setting. The selected
unit will apply to all temperature displays in this window.
NOTE The unit of all temperature related display will be
changed simultaneously.
To display the dew point temperature, press the indoor
temperature window until the “DEW” indicator is displayed.
To display maximum, minimum temperatures,
1. Press the indoor temperature window or repeatedly
until the "DEW" icon appears.
2. Press [MEMORY] repeatedly for the desired record.
The time and date of the record will also be displayed
alternatively with the “STAMP” icon in the clock window.
The display will automatically return to the current
temperature or dew temperature whatever is previously
displayed if the unit is left untouched for about one minute.
To clear the memory,
1. Press the indoor temperature window or repeatedly
until the "DEW" icon appears.
2. Press and hold [MEMORY] till the key tone is heard.
3. Press [MEMORY] to check the memory is clear.
INDOOR HUMIDITY
The current indoor relative humidity, taken by the indoor
baro-thermo-hygrometer, is displayed on the indoor
hygrometer window.
To display the maximum, minimum and current humidity,
1. Press the indoor humidity window.
2. Press [MEMORY] repeatedly for the desired record.
The time and date of the record will also be displayed
alternatively with the “STAMP” icon in the clock window.
To clear the memory,
1. Press the indoor humidity window.
2. Press and hold [MEMORY] until the key tone is heard.
3. Press [MEMORY] to check the memory is clear.
OUTDOOR AND CHANNEL TEMPERATURES
The temperature readings taken by the outdoor thermo-
hygrometer and separate thermo or thermo-hygro sensors
are displayed on the outdoor and channel temperature
window.
As this window can display up to four different sets of data,
specify the instrument or channel you want to read.
To do so,
1. Press the outdoor/channel temperature window.
2. Press [CHANNEL] to go from the outdoor reading
taken by the outdoor thermo-hygrometer to those taken
by individual sensors (Channel 1, 2 or 3).
The outdoor thermo-hygrometer is also capable of
detecting the dew point temperature as well as the wind
chill reading. To display such information, press the window
repeatedly.
The temperatures can be displayed in degrees Centigrade
(˚C) or Fahrenheit (˚F).
To select the display unit,
1. Press the outdoor/channel temperature window.
2. Press [UNIT] repeatedly for the desired setting. The
selected unit will apply to all temperature displays in this
window.
NOTE The unit of all temperature related displays will
change simultaneously.
To display the maximum, minimum temperatures,
1. Press the outdoor/channel temperature window or
repeatedly until the "DEW" icon appears.
2. Press [CHANNEL] for the outdoor thermo-hygrometer
or the desired channel.
3. Press [MEMORY] repeatedly for the desired record.
The time and date of the record will also be displayed
alternatively with the “STAMP” icon in the clock window.
To display the dew point temperature for a channel, press
the window again when the channel temperature is located.
To clear the memory,
1. Press the outdoor/channel temperature window or
repeatedly until the "DEW" icon appears.
2. Press [CHANNEL] for the outdoor thermo-hygrometer
or the desired channel.
3. Press and hold [MEMORY] until the key tone is heard.
4. Press [MEMORY] to check the memory is clear.
OUTDOOR AND CHANNEL HUMIDITY
The relative humidity readings taken by the outdoor thermo-
hygrometer and separate thermo-hygro sensors are
displayed on the outdoor/channel humidity window.
As this window can display up to four different sets of data,
specify the instrument or channel you want to read.
To do so,
1. Press the outdoor/channel humidity window.
2. Press [CHANNEL] to go from the outdoor reading
taken by the thermo-hygrometer to those taken by
individual sensors (Channel 1, 2 or 3).
To display the maximum, minimum and current
humidity,
1. Press the outdoor/channel humidity window.
2. Press [CHANNEL] for the outdoor thermo-hygrometer
or the desired channel.
3. Press [MEMORY] repeatedly for the desired record.
The time and date of the record will also be displayed
alternatively with the “STAMP” icon in the clock window.
To clear the memory,
1. Press the outdoor/channel humidity window.
2. Press [CHANNEL] for the outdoor thermo-hygrometer
or the desired channel.
3. Press and hold [MEMORY] until the key tone is heard.
4. Press [MEMORY] to check the memory is clear.
WMR968_EN_output 12/17/2004, 15:055
5

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Oregon Scientific WMR968 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info