Example 1
The lift has been active for more then 20 days. (today it is Monday)
A user complains that the lift has stopped several times during movement on Wednesday and Friday.
When the error-log has been read out the display could show:
Note that the first error you read is the most recent one.
_ _ _ 2 2 2 _ _ 2 2 2 2_ _ _ _ _ _ _ _ -
or
_ _ 2 2 2 _ _ 2 2 2 2_ _ _ _ _ _ _ _ _-
Display-error 2 means that the swivel seat-switch was operated during controlling the lift.
In this case it is obvious that the problem has to be found in the wiring or the adjustment of the switch.
Example 2
There was a problem, but the user is not able to inform you.
When you read the error log you see the following errors.
5 2 _ _ 5 _ 5_ d _ _ 6 7 _ _ 0 _ _ 0 d-
Error 5 means that the lift was controlled on 2 locations at the same time.
Error 2 means that the swivel seat-switch was operated during controlling the lift.
Error 0 means that the armrest-switch was operated during controlling the lift.
Error F means that the safety footrest was controlled during controlling the lift
6 and 7 show to you that the lift had entered sleepmode, because the batteries were not charged for 1
hour.
In this case you should check if the control on the armrest goes back in middle position when released
or if one switches on the remote or in the armrest is function properly.
When for example the remote is not mounted properly, it could happen that a button stays controlled
while is has been released.
Also check the safety plate footrest and safety switch footrest left.
The error-log shows that 4 or 5 and probably 10 or 11 days ago, this was a reason why the chairlift
was stopped.
Does the plate of the footrest move back when it is controlled?
Note that also the user can have caused this, because there was an object on the stairs.
Display error 2 and 0 could be a mistake in operating by the costumer.
To be sure, you can check the function of the armrest-switch and swivelseat-switch.
The 6 en 7 indicates that the chairlift had entered the sleepmode.
Was there a power-failure on the 230~net (mains voltage) or …..?
To be sure check the wiring of the charge-point.
Please note that the error-log makes and sees no difference in failure or mistake in controlling
by the user.
It only is a tool to help you find the reason, why the chairlift did not work.
35

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Otolift One wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info