668497
43
Zoom out
Zoom in
Vorherige Seite
1/51
Nächste Seite
ERRORS shown b
y
SENSOR CONTROL BOARD (SCB) 22-aug-11
Display description problem Where to look / what to do
" " (nothing) = PCB standbymode/ sleepmode
1 All OK, ready to run Read softwareversion of all system
E25 No response main drive. (via CAN) Check Flatcable / Replace Main Board press lowest button on SCB
E26 Fail Safetyline test Main board Replace Main Board
Display will show 'd…L…C'
E30 No response level board. (via CAN) Check Flatcable / Replace Level Board
d… = version mainboard (drive)
E31 Fail Safetyline test Level board Replace Level Board
L… = version Leveldrive
E32 Fail Selftest Level board. Critical switch safetyline / Replace Level Board
C…= version sensor Control board
E33 * Overload LevelPCB / Levelmotor Long time high load. Continues heavy load out middle of outputshaft / Replace Level Board
E34 *
High / low supply voltage
{In software before version L27, this was only high supply voltage}
voltage fault on Level or Main board (Main board should respond earlier)
E35 Locked rotor / encoder fault Level motor Check wiring encoder / motor / Replace Level Board
E36 Motor direction error Critical switch safetyline / Check connection Level Motor
E37 Gate supply voltage missing, SLA and/or SLB not active (Tilt sensor?) Critical switch safetyline / Replace Level Board Calibrate chair and liftsensor
E38 *
High impuls current (overcurrent) {In softw. before version L27,this was low supply volt error}
Blocking of motor / Check wiring encoder Adjust seat horizontal. (by handwind)
press both buttons on SCB
E40 PCB error Sensor control Board Replace Sensor Control Board => calibate sensors after replacement display will show blinking 'h'
E41 Liftsensor Fault 1 (ADC) Replace Sensor Control Board => calibate sensors after replacement Hold buttons until blinking 'h' stops.
E42 Liftsensor Fault 2 (V) Replace Sensor Control Board => calibate sensors after replacement When 'h' is continue visible release buttons
E43
Liftsensor Fault 3 ()
Replace Sensor Control Board => calibate sensors after replacement Sensors are calibrated.
E44 Checksum error (Configs) Replace Sensor Control Board => calibate sensors after replacement
E45 System never has been calibrated. (factory default) Calibrate sensors
E50 Chairsensor outside range -3,5 or +3,5 degrees First check and set angle of Chairframe, do restart, and read 'new' error / or sensor not correctly calibrated
E51 Chairsensor Fault 1 (ADC) Replace Chairsensor => calibate sensors after replacement / check wiring Tiltsensor
E52 Chairsensor Fault 2 (V gyro) Replace Chairsensor => calibate sensors after replacement Set dynamic
E53
Chairsensor Fault 3 (V x/y) Replace Chairsensor => calibate sensors after replacement push highest button.
E54
Chairsensor Fault 4 ()
Replace Chairsensor => calibate sensors after replacement / check encodercable/connector While pressing highest button, press lowest
button 3 times.
(Then release highest button)
E60
Tilt sensor activated (outside -5 or +5deg )
Dual Safety line A (SLA) and B (SLB) not intact.
Tiltsensor activated / Problem wiring tiltsensor or flatcable / PCB fault LEVEL / SCB / Tilt Dot OFF at display is normal dynamics
E61 Dual Safety line A (SLA) not intact. Problem wiring tiltsensor or flatcable / PCB fault LEVEL / SCB / Tilt Dot ON is lower dynamic
E62 Dual Safety line B (SLB) not intact. Problem wiring tiltsensor or flatcable / PCB fault LEVEL / SCB / Tilt
E63
Fault in test Dualsafety-line (Given when fault is not E26/E31/E60/E61 or E62) [ NOTE * = no fast beep ]
ERRORS shown b
y
LEVEL BOARD
LED's description problem
LED 1 (YELLOW) Shows CPU status 0,5 Hz = OK / OFF = PCB not ON / ON = error
LED 2 (RED) Shows Status Dual Safetyline (output filter)
OFF Safety line filter A & B on
5Hz Safety line filter A off , B on
5Hz
1sON/1sOFF
Safety line filter A on , B off
ON Safety line filer A & B off
LED 3 (GREEN)
OFF / 0,5 Hz OK Motor control not active = off / Motor control active = 0,5 Hz
ON
Low / High supply voltage error / Motor direction error / Fail Selftest Level drive / Gate supply voltage missing (SCB for detail info)
5Hz 1sON/1sOFF
Locked rotor / encoder fault Level motor
5Hz Overcurrent/ Overload Level motor
43

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Otolift One wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info