INSTRUCTION MANUAL DIMMER [UNIVERSAL DIMMER FOR DIN-RAIL]
Technical Features
Safetey instructions
Supply voltage
230 V, 50Hz
CAUTION!!
DANGER OF LIFE / RISK OF FIRE AND ELECTRIC SHOCK!!
Power consumption
3 VA
LOAD
LED 1*: Dimmable 230V~ LED lamps (leading edge dimming)
4 - 100 W
Installation and assembly of electrical equipment must be carried out only by professional electrician!
Connect the supply voltage/frequency as stated on the product!
Disconnect device from power supply for wiring and installation purposes!
Check power supply is disconnected!
Defective devices have to be put out of service immediately
Warranty void if housing opened by unauthorised person!
The electronic circuit is protected against a wide range of external influences. Incorrect operating may occur if
external influences exceed certain limits!
Installation and assembly of electrical equipment must be in accordance with local building and electrical codes!
LED 2*: Dimmable 230V~ LED lamps (trailing edge dimming).
4 - 100 W
LED 2*: Dimmable 12V~ LED lamps (trailing edge dimming) with
electronic transformer, type C
Max. 300 W transformer / Max. 1 lamp
per transformer (E.g.: 6 transf. á 50W)
RLC*: Incandescence, 230V Halogens & LV Halogens
with Electronic transformer
15 400 W
RLC*: Halogens with Ferromagnetic transformer
20 250 W
CFL*: Dimmable Compact Fluorescent Lamps
20 200 W
Max. number of pushbuttons
3 lighted pushbuttons & unlimited non-
lighted pushbuttons
Dimensions
17,5 x 90 x 60mm (1 module)
Weight
68 g
Important Note
Permitted ambient temperature
0º … +40ºC
*Check the technical specification of the lamps! For all transformers and lamps, please take into account the
specifications of the manufacturer!
Type of protection
IP20 DIN EN 60529
Function overview
Wiring diagram
Universaldimmer for DIN-rail. Protected against overload and short circuit. Built-in heat protection. Controlled by pushbutton.
1 x Rotary switch to select the connected load:
- LED 1: Dimmable 230V~ LED lamps (leading edge dimming)
- LED 2: Dimmable 230V~ LED lamps (trailing edge dimming).
Dimmable 12V~ LED lamps (trailing edge dimming) with electronic transformer, type C
- RLC: For R, L and C loads. Automatic detection of the load type. Load examples:
Incandescence, 230V Halogens & LV Halogens with Electronic transformer and Halogens
- CFL: Dimmable Compact Fluorescent Lamps.
1 x Rotary switch to select the minimum light level
Installation
CAUTION! You must select with the “Load rotary switch” the correct type of connected load in order to avoid damages
of the dimmer or the lamps!
1 Disconnect installation from power supply and check that power supply is disconnected.
2 Select with the Load rotary switch the type of lamp / load you will connect.
3 Install the dimmer according to the wiring diagram.
4 Make sure the loads are connected properly and reconnect power supply.
Press shortly the pushbutton to switch the lamps on and dim with a long press to the minimum light level.
If the lamps are not switched on correct (e.g. light flickering) you have to disconnect the installation from power supply.
Select with the “light level rotary switch” the appropriate and correct minimum light level.
Operation
With a long press you can dim!
Press shortly the pushbutton to switch the lamps on and off!
Memory function
To enable or disable the memory function press with an electrically insulated, prick object into the memory hole.
Is the memory function activated the LED is permanently illuminated.
=> Activated memory function: Lamp(s) switches on with the brightness / light level of the last switch off.
=> Deactivated memory function: Lamp(s) switches on with max. brightness / light level.
Master-slave-function
By master-slave-function (please see master-slave
installation) several dimmers can be controlled by one
pushbutton (higher loads). The pushbutton have to
connected to the master-device.
Being installed as slave the LED will flash. The
pushbutton input (terminal 6) and the memory function
of the slave are deactivated.
To get the dimmer out of slave mode it
is necessary to
disconnect and reconnect the (slave)dimmer.
Standard-installation
Master-slave-installation
2

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Paladin 872 110 led wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info