Chapter 6 Maintenance and inspections
76
6. SERVO
5. HUMID
9. WIRELESS RF
7. RF
WARNING lamp Lights for 90 minutes following the release of the
condensation detection after the condensation
formation was detected.
Indications on LCD screen
HUMID display lights if condensation is
detected.
HUMID display flashes for an additional 10 to 90
minutes after condensation detection is canceled.
Tally lamp Flashes 4 times per second for 90 minutes after
condensation detection is canceled.
Viewfinder HUMID display flashes from the time
condensation is detected until 90 minutes after
the condensation detection is released.
Alarm Sounds continuously (4 times a second during
recording).
Warning description Condensation has formed.
VTR unit operation The recording operation continues but if the tape
sticks, recording will stop.
For 80 minutes after the condensation detection is
released, the drum is rotated and no operations
are accepted.
Corrective action Stop the tape travel and turn off the power. If the
HUMID display fails to be cleared even when the
power is turned back on, wait until it clears.
WARNING lamp Flashes four times a second (during recording
and playback).
Indications on LCD screen
SERVO display lights (during recording and
playback).
Tally lamp Flashes four times a second (during recording
and playback).
Viewfinder SERVO display lights (during recording and
playback).
Alarm Sounds four times a second (during recording and
playback).
Warning description The servo is disturbed.
VTR unit operation Operation continues but the unit may not operate
correctly.
Corrective action Turn off the power and consult your dealer. The
warning display may flash for a moment and then
disappear when tape transport commences: this
is normal and not indicative of a failure or
malfunctioning.
WARNING lamp Flashes four times a second (during recording).
Indications on LCD screen
RF display flashes (during standby and recording).
Tally lamp Flashes four times a second (during recording).
Viewfinder RF display lights (during recording).
Alarm Sounds four times a second (during recording).
Warning description The video heads have become clogged. There is
a problem in the video system.
VTR unit operation The cleaning rollers are activated to clean the
heads (for a maximum of 10 seconds).
Recording continues but the signals may not be
recorded correctly.
The indications on LCD screen are retained until
the REC/PAUSE status is established. They go
off as soon as the unit transfers from the
REC/PAUSE mode to another mode.
Corrective action Clean the heads. If the signals cannot be
recorded correctly even after cleaning, consult
your nearest service center.
WARNING lamp Flashes four times a second (during standby and
recording).
Indications on LCD screen
No indication
Tally lamp Flashes four times a second (during recording).
Viewfinder WIRELESS RF display lights for at least 3
seconds during recording.
Alarm Sounds four times a second (for at least 3
seconds during standby and recording).
Warning description Poor wireless signal reception.
VTR unit operation Operation continues but the signals from the
wireless microphone cannot be received.
Corrective action Check the microphones power supply and the
reception condition of the receiver.
8. 1394
WARNING lamp Flashes four times a second (during recording).
Indications on LCD screen
1394 E-22 display flashes.
Tally lamp Flashes four times a second (during recording).
Viewfinder
O When error code 92 appears, 1394 INITIAL
ERROR display lights (during standby and
recording).
O With all other error codes or when 1394 is
selected as the REC SIGNAL menu item
setting, the error is not displayed in the
viewfinder.
Alarm Sounds four times a second (during recording).
Warning description There is something wrong with the signals
supplied to the DVCPRO connector.
VTR unit operation Operation continues, but something is wrong with
the signals supplied to the DVCPRO connector.
Corrective action Check the IEEE 1394 cable and DVCPRO
connector connections and the settings of the
external units or menu settings, and then turn the
power off and back on.
If the warning display is not cleared, check 6-3-2
Error codes, and consult your nearest service
center.
76

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Panasonic AJ-SDC 615P wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info