7
Chapter 7 Menu description tables
95
7-5-8 IRIS
7-6 FILE
7-6-1 CARD READ/WRITE
TITLE1 - 8:
For setting a title consisting of not more than
8 characters.
Item/
Data storage
Variable
range
Remarks
R.SELECT 1
:
8
For selecting the number of the file whose
data is to be read.
READ
For reading the data on the setup card.
WRITE
For writing the camera data onto the setup
card.
W.SELECT 1
:
8
For selecting the number of the file in which
the data is to be written.
CARD CONFIG
For formatting the setup card.
TITLE READ
For reading the titles given to the data on the
setup card.
7-6-2 CARD R/W SELECT
VTR MENU R/W ON
OFF
For selecting whether or not to handle the
VTR MENU settings during CARD READ/
WRITE data operations.
Item/
Data storage
Variable
range
Remarks
ID READ/WRITE ON
OFF
For selecting whether or not to handle the
CAMERA ID during CARD READ/WRITE
data operations.
SYSTEM MENU
R/W
ON
OFF
For selecting whether or not to handle the
SYSTEM SETTING items during CARD
READ/WRITE data operations.
PAINT MENU
LEVEL R/W
ON
OFF
For selecting whether or not to handle the
PAINT MENU adjustment values during
CARD READ/WRITE data operations.
PAINT MENU
SW(∫) R/W
ON
OFF
For selecting whether or not to handle the
PAINT MENU settings during CARD READ/
WRITE data operations.
VF MENU R/W ON
OFF
For selecting whether or not to handle the VF
MENU settings during CARD READ/WRITE
data operations.
USER MENU
SELECT R/W
ON
OFF
For selecting whether or not to handle the
FILE MENU settings during CARD READ/
WRITE data operations.
MAINTE MENU
R/W
ON
OFF
For selecting whether or not to handle the
MAINTENANCE MENU settings during CARD
READ/WRITE data operations.
OPERATION MENU
R/W
ON
OFF
For selecting whether or not to handle the
OPERATION MENU settings during CARD
READ/WRITE data operations.
The underlining in the variable range column indicates the setting in the preset mode.
Item/
Data storage
Variable
range
Remarks
A.IRIS PEAK/AVE 000
:
040
:
100
For determining the ratio of the peak to the
AUTO IRIS reference.
The higher the ratio, the greater the response
to the peak inside the iris detection window;
the lower the ratio, the greater the response
to the average value inside the iris detection
window.
A.IRIS MODE NORM1
NORM2
CENTR
For selecting the auto iris detection window.
NORM1: Window from the screen center
NORM2: Window from the bottom of the
screen
CENTR: Window in the shape of a spot at
the screen center
S.IRIS LEVEL 000
:
080
:
100
For setting the SUPER IRIS target value.
IRIS GAIN CAM
LENS
For selecting the IRIS GAIN adjustment.
<Note>
With lenses equipped with an extender
function (a2, a0.8 etc.) sold before the DIGI
POWER type manufactured by FUJINON, iris
corrective control is performed with the
extender function on at the LENS setting. As
such, this unit’s iris control will not function
correctly when CAM has been selected as the
setting for this item.
IRIS GAIN VALUE 01
:
08
:
20
For setting the IRIS GAIN adjustment value.
The setting takes effect when IRIS GAIN has
been set to CAM.
A.IRIS LEVEL 000
:
060
:
100
For setting the AUTO IRIS target value.