ENGLISH
IMPORTANT SAFETY INSTRUCTIONS FOR THE USER
Before using the vacuum cleaner, please observe these basic precautions.
WARNING: To reduce the risk of fire, electric shock, or injury
This appliance is not intended for use by young children or infirm person without supervision; young children should be
supervised to ensure that they do not play with the appliance.
• Do not use the appliance if the mains lead or plug is damaged or faulty.
This appliance is provided with a mains lead and if this becomes damaged, it must be repaired by an Authorized Service Centre
or a qualified person in order to avoid any hazard.
• Unplug from the socket when not in use and before cleaning the appliance or undertaking maintenance operations.
• Turn off the appliance before removing the plug. Do not pull on the mains lead, always pull on the plug body itself.
• Do not handle plug or vacuum cleaner with wet hands.
• Do not use wet filters after wash, make sure they are completely dry to avoid damaging the cleaner.
• Do not vacuum flammable or combustible substances, neither use in areas where they may be present.
• Do not vacuum hot ash, embers or large and sharp objects.
Do not vacuum water or other liquids.
• Keep the vacuum cleaner away from heat sources such as radiators, fires, direct sunlight, etc.
This vacuum cleaner is fitted with a thermal cut-out device which automatically turns off the cleaner to prevent overheating of the
motor. When this happens, disconnect the cleaner from the mains socket and check the dust compartment and filters as they
may be full or clogged with fine dust. Check for any other obstructions in the hose or tube. After removing the obstruction, leave
the cleaner to cool down until the thermal cut-out resets after approximately 60 minutes.
A- IDENTIFICATION OF MAIN PARTS
C - HOW TO OPERATE YOUR CLEANER
B - HOW TO ASSEMBLE YOUR CLEANER
A)
Turbine nozzle (
Only MC-CG663)
B)
Floor nozzle (Only MC-CG661)
C)
Connection pipe
D)
Hose
E)
Suction regulator
F)
Curved wand
G)
Telescopic wand
(MC-CG663)
(MC-CG661)
H)
Hose inlet
I )
Dust indicator
J)
Dust cover
K)
ON /OFF Switch pedal
L)
Cord rewind pedal
M)
Crevice nozzle
N)
Dusting brush
O)
Paraquet floor nozzle (Only MC-CG661)
P)
Exhaust cover
Q)
Plug
R)
Variable power control button
B-1 Insert connection pipe into hose inlet until it locks. When
removing hose assembly, pull out connection pipe with
pushing down two connection buttons.
NOTE: Do not bend, pull and step on the hose or put
anything heavy on it.
B-2 Insert the hose unit into the upper end of the connected
telescopic wand, and the floor nozzle to the other end.
(Only MC-CG661)
B-3 Insert the hose unit into the upper end of the telescopic
wand. Twist the telescopic wand so that the round hole
will fit into the tab on the hose unit. (When removing the
hose, push the tab down whilst pulling on the telescopic
wand)
Attach the Turbine Nozzle to the other end (Only MC-
CG663)( Removal as per reverse procedure)
B-4 Keep hold of the tube grip and pull out the tube to the
required length.
C-1 Pull out the mains lead and put the plug into the wall
socket.
C-2 Gently press at the centre of the switch pedal to turn
ON the vacuum cleaner.
Press the pedal again to turn it OFF.
C-3 Power control
To increase or decrease the power, turn the variable
power control button.
C-4 Switching between carpet and flooring
Flooring: Press lever A
Carpet: Press lever B
*Switching 3 positions for MC-CG663.
Flooring (PARQUET): Set position A
Carpet (short): Set position B
Carpet (long or hard to push): Set position C
C-5 The curved wand of the hose is attached with a manual
suction regulator, which allows you to briefly reduce the
suction level.
C-6 After you finish vacuuming, remove the plug from
the wall socket and press the cord rewind pedal.
When rewinding the power cord, press the cord rewind
pedal by holding the plug so that it does not become
damaged.
C-7 Storage position
Insert the wand holder straight into the wand
supporter.
C-8 Park system
For short breaks during vacuuming, slide the hook
attached to the nozzle pipe into the slot on the rear side
of the cleaner.
NOTE: When you use park position, we suggest the
appliance is switched off.
18

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Panasonic mc cg 661 ke 79 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info