5
OFF/ON
TEMP
MODE
FAN SPEED
AUTO
TIMER
AIR SWING
R
ESET
2
3
5
4
1
SLEEP
6
M
ANUALSELECT SET/CANCEL
A
B
AUTO
HEAT
COOL
COOL
DRY
FAN
SPEED
A
B
HOW TO OPERATE
To start the operation
Press 1.
•POWER indicator (green) on the indoor unit will light up.
•To stop, press once more.
Setting Mode
Press 2 to select:-
Cooling Model
AUTO Automatic Operation
COOL Cooling Operation
DRY Soft Dry Operation
FAN Air Circulation Operation
Heat Pump Model
AUTO Automatic Operation
HEAT Heating Operation
COOL Cooling Operation
DRY Soft Dry Operation
PREPARATION BEFORE OPERATION
Indoor Unit
1 Connect the power supply cord to an independent
power supply.
Setting Temperature
Press 3 to increase or decrease the temperature.
The temperature can be set between 16°C ~ 30°C
Recommended temperature:
During AUTO Operation, press 3 to select:-
Operation with 2°C higher than the standard
temperature.
Operation with the standard temperature.
Operation with 2°C lower than the standard
temperature.
Standard Temperature
Cooling Model
Once the Automatic Operation is selected, the indoor
temperature sensor operates automatically to select
the desired operation mode with Cooling or Soft Dry.
After the operation mode has been selected, the
mode does not change.
Heat Pump Model
At the beginning of the automatic operation, Heating,
Cooling or Soft Dry is automatically selected according
to the indoor temperature.
After the operation mode has been selected, the
mode does not change.
Operation
Cooling
Soft Dry
Standard
temperature
25°C
22°C
Indoor
temperature
23°C
Operation
Cooling
Soft Dry
Heating
Standard
temperature
25°C
22°C
21°C
Indoor
temperature
23°C
20°C
Cooling Model
COOL –> 26°C ~ 28°C
DRY –> 1°C ~ 2°C
lower than the
room temperature
Heat Pump Model
COOL –> 26°C ~ 28°C
DRY –> 1°C ~ 2°C
lower than the
room temperature
HEAT –> 20°C ~ 24°C
Operation Details
COOL – Cooling Operation
To set the room temperature at your preference
cooling comfort.
AUTO – Automatic Operation
Sense indoor temperature to select the optimum
mode.
Temperature is not displayed on the remote control
during AUTO operation.
DRY – Soft Dry Operation
•A very gentle Cooling Operation, prior to
dehumidification. It does not lower the room
temperature.
During Soft Dry operation, the indoor fan operates at
Low Fan Speed.
HEAT – Heating Operation
(for Heat Pump Model only)
Heat is obtained from outdoor air to warm up the
room. When the outdoor ambient air temperature
falls, the heating capacity of the unit might be
reduced.
Defrosting Operation
Depend on the outdoor temperature, the operation
occasionally stops to melt the frost on the outdoor
unit.
FAN – Air Circulation Operation
(for Cooling Model only)
Heated air rises and collects at the top of the room.
The air circulation circulates the heated air downward,
thus increasing heating effectiveness. When the unit
is installed floor mounted, you should set the
temperature higher than that of ceiling mounted.
At ceiling mounted At floor mounted
1
12CTP5-01EN(01-09) 12/24/09, 11:29 AM5
6

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Panasonic S-A18CTP wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info