SPECIFICA TIONS
Amplifi er section
RMS Output power stereo mode
F ront Ch (both channels driven)
5 W per channel (6
), 1 kHz, 10% THD
T otal RMS stereo mode power 10 W
FM/AM tuner , terminals section
Preset station FM 30 stations
AM 15 stations
Frequency Modulation (FM)
F requency range
87.50 MHz to 108.00 MHz (50 kHz step)
Antenna terminals 75
(unbalanced)
Amplitude Modulation (AM)
F requency range
522 kHz to 1629 kHz (9 kHz step)
520 kHz to 1630 kHz (10 kHz step)
Headphone jack
T erminal Stereo , 3.5 mm jack
Output lev el (CD , 1 kHz, –20 dB)
0.7 mW + 0.7 mW , 32 (Max)
Music port (top)
Sensitivity
Nor mal 490 mV , 15 k
High 100 mV , 15 k
T erminal Stereo , 3.5 mm jack
Disc section
Disc played (8 cm or 12 cm)
(1) CD-Audio (CD-D A)
(2) CD-R/RW (CD-D A, MP3
formatted disc)
(3) MP3
MPEG-1 Lay er 3, MPEG-2 Layer 3
Pick up
W av elength 785 nm (CD)
Laser power CLASS 1 (CD)
Audio output (Disc)
Number of channels 2 ch (FL, FR)
FL = F ront left channel
FR = F ront r ight channel
USB section
USB P ort
USB Standard USB 2.0 full speed
Media fi le format suppor t MP3 (
.mp3)
USB device fi le system F A T 12, F A T 16, F A T 32
USB por t pow er 500 mA (Max)
Speaker section
T ype 1 wa y , 1 speaker system (Bass refl e x)
Speaker unit(s)
Full range 10 cm cone type
Impedance 6
Output sound pressure 83 dB/W (1 m)
Frequency range 61 Hz to 17 kHz (–16 dB)
95 Hz to 15 kHz (–10 dB)
Dimensions (WxHxD)
139 mm x 224 mm x 136 mm
Mass 1.3 k g
General
P ower suppl y AC 220 to 240 V , 50 Hz
P ower consumption 12 W
Dimensions (WxHxD)
184 mm x 123 mm x 228 mm
Mass 1.1 k g
Operating temperature range 0°C to +40°C
Operating humidity range
35% to 80% RH (no condensation)
Power c onsum ptio n in sta ndby mo de :
0. 3 W (a ppr oximate )
1) S pec ifi catio ns are su bjec t to chan ge wit hout
notice.
Ma ss and d imen sion s are app roxim ate.
2) T ot al har moni c dist or tion i s meas ured by th e
dig ita l spec tru m analy zer .
MAINTENANCE
If the surfaces are dirty
T o cl ean t his uni t, w ipe wi th a sof t , dr y clot h.
• Never us e alco hol, pa int thi nner or b enzine to c lean t his uni t.
• Befor e usin g chem ica lly treate d clot h, read th e instr uct ion s that ca me with t he cl oth car efully.
Inside o f p roduct
CA UTION!
• DO NO T INST ALL OR PLACE THIS UNIT
IN A BOOKCASE, BUIL T -IN CABINET OR
IN ANO THER CONFINED SP ACE. ENSURE
THE UNIT IS WELL VENTILA TED. T O
PREVENT RISK OF ELECTRIC SHOCK OR
FIRE HAZARD DUE TO O VERHEA TING,
ENSURE THA T CURT AINS AND ANY OTHER
MA TERIALS DO NOT OBSTRUCT THE
VENTILA TION VENTS.
• DO NO T OBSTRUCT THE UNIT’S
VENTILA TION OPENINGS WITH
NEWSP APERS, T ABLECLOTHS, CURT AINS,
AND SIMILAR ITEMS.
• DO NO T PLA CE SOURCES OF NAKED
FLAMES, SUCH AS LIGHTED CANDLES, ON
THE UNIT .
• DISPOSE OF BA TTERIES IN AN
ENVIRONMENT ALL Y FRIENDL Y MANNER.
THIS UN IT IS INTENDED FO R USE IN
MO DERA TE C LIMA TES.
The s ocket o utlet s hall b e inst alled n ear the
equ ipme nt and e asily a cce ssib le.
The m ains p lug of th e power su pply c ord sh all
remain readily operable.
T o co mplete ly dis conn ect t his ap paratus fr om the
AC Main s, dis conn ect t he power s uppl y cord p lug
from AC rec eptac le.
Thi s prod uct m ay recei ve radi o inter feren ce
cau sed by mo bile te lep hone s duri ng use. If
suc h inter feren ce is a ppare nt, pl ease in crea se
sep arati on bet ween t he pro duc t and th e mob ile
tele phone.
CA UTION!
THIS PRODUCT UTILIZES A LASER.
USE OF CONTROLS OR ADJUSTMENTS
OR PERFORMANCE OF PROCEDURES
O THER THAN THOSE SPECIFIED HEREIN
MA Y RESUL T IN HAZARDOUS RADIA TION
EXPOSURE.
DO NO T OPEN CO VERS AND DO NOT REP AIR
Y OURSELF . REFER SER VICING TO QU ALIFIED
PERSONNEL.
W ARNING:
T O REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK OR PRODUCT D AMA GE,
• DO NO T EXPOSE THIS APP ARA TUS
T O RAIN, MOISTURE, DRIPPING OR
SPLASHING AND THA T NO OBJECTS
FILLED WITH LIQUIDS, SUCH AS V ASES,
SHALL BE PLA CED ON THE APP ARA TUS.
• USE ONL Y THE RECOMMENDED
A CCESSORIES.
• DO NO T REMO VE THE CO VER (OR BA CK);
THERE ARE NO USER SER VICEABLE
P ARTS INSIDE. REFER SER VICING T O
QU ALIFIED SER VICE PERSONNEL.
Operating Instructions
CD Stereo System
Model No . SC-PM02
Dear Customer
Tha nk you for pu rcha sing t his pr odu ct.
For op timu m per form anc e and safe ty ,
read t hese i nstru cti ons th orou ghly b efore
co nnec ting , oper ating or a djus ting t his pro duc t.
Keep t his ma nual for f uture re feren ce.
The se ope rating i nstru cti ons are a ppli cab le for
the fo llowin g system :
System
SC-PM02
Main unit
SA-PM02
Speakers
SB-PM02
Y our u nit may n ot loo k exact ly the s ame as
illustrated.
SU P P L IED A CCE SS ORIE S
Plea se che ck an d ide ntif y the s upp lied ac ces sor ies.
Use nu mber s ind icate d in paren these s when a skin g
for re plac ement p art s. (As of May 2010)
1 x A C mains lead
(K2C Z3 YY 00005)
1 x FM indoor antenna
(RS AX000 2)
1 x Antenna plug adaptor
(K 1 YZ02 0000 1 3)
1 x AM loop antenna
(N 1 D YYYY 000 1 0)
1 x Remote control
(N2 QA YB000 555)
Placement
Set t he unit u p on an even s urf ace away from
dire ct su nlig ht, hig h tempe ratures , high hu midi ty,
and exc ess ive vibr atio n. These c ond itio ns ca n
dam age th e cab inet an d other c omp onen ts,
the reby sh orte ning t he uni t’s ser vi ce life.
Plac e it at leas t 1 5 c m away from wall s urf aces to
avoid d istor ti on and u nwanted a cous tic al ef fect s.
Do no t plac e heav y items o n the un it.
V oltage
Do no t use hig h volt age power s ourc es. Thi s can
overl oad the u nit an d caus e a fi re.
Do no t use a DC p ower sour ce. Che ck th e sourc e
car efully w hen se tti ng the u nit up o n a ship o r
oth er plac e where D C is use d.
A C mains lead protection
Ensur e the AC mai ns lead i s con nec ted cor rec tly
and n ot dam aged. Po or con nec tion a nd lea d
dam age c an caus e fi re or el ect ric sh oc k. Do no t
pul l, bend , or plac e heav y item s on the l ead.
Gra sp the p lug fi rmly wh en un plug ging t he lead.
Pull ing the AC m ains le ad can c ause e lec tric
shock.
Do no t hand le the p lug wit h wet hand s. Thi s can
cau se ele ctr ic sho ck .
SAFETY PRECA UTIONS
PLA CEMENT OF SPEAKERS
PREP ARING THE REMO TE CONTROL
Use al kali ne or man gane se bat terie s.
Ins ert s o the po les (+ an d –) m atch th ose in t he
remote control.
Not e on usi ng the r emo te con trol
• Do no t mix ol d and new b atter ies.
• Do no t use di ffere nt ty pes of b atter ies at th e
same time.
R6 /LR6, AA
(not i ncluded)
• Do no t take apar t or s hor t circ uit th e batte ries.
• Do not at tem pt to rec harge al kalin e or
manganese batteries.
• Do no t use bat teri es if th e coveri ng has be en
peeled off.
• Do no t heat or ex pose to fl ame.
• Do not l eave the bat ter y( ies ) in an autom obil e
exp osed to d irec t sunli ght for a l ong pe rio d of
tim e with d oors a nd win dows cl osed .
• Mis hand ling of b atter ies in t he rem ote con trol
can c ause e lec trol yte l eakage, w hic h may caus e
a fi re.
• Rem ove the bat teri es if th e remote c ontro l is not
go ing to be us ed for a lo ng per iod of t ime. Stor e
in a c ool, d ark pl ace.
Speakers are designed identically so that no left
or ri ght ch annel o rient ation i s nec essar y .
Y ou c annot t ake the fro nt net of f the s peaker s.
Use o nly th e supp lie d spe aker s
Usi ng othe r spea kers ca n damag e the un it and
sou nd qua lit y will be n egati vely af fecte d.
Note:
• Keep you r spea kers at lea st 1 0m m away from
the sys tem for pro per ventil ation.
• The se spe akers d o not have mag neti c shie ldin g.
Do no t place t hem ne ar televis ions , pers onal
co mpute rs or oth er devi ces e asily i nfl uen ced by
magnetism.
• Y ou c an dam age your s peaker s and s hor ten
the ir usef ul life if yo u play so und at hi gh levels
over ex tend ed pe rio ds.
• Red uce t he volum e in the fo llowi ng cas es to
avoid d amag e.
– Whe n playin g disto rte d soun d.
– Whe n adju sting t he sou nd qua lit y .
Caution
• Use t he sp eak ers on ly wit h the
re comm end ed syst em. Fa ilur e to do so
ca n dama ge th e amp lifi er and s pea kers ,
and c an ca use fi r e. Co nsult a q uali fi ed
se rvi ce pe rso n if dam age o ccur s or
if a su dde n chan ge in p er form ance i s
apparent.
• Do no t at tach t hes e spe aker s to walls o r
ceilings .
CAUT IO N
Dan ger of ex plos ion if b atter y i s inc orre ctly r epla ced. R epla ce on ly wit h the sa me or eq uival ent
t ype re comm ende d by the ma nufac turer . Dis pose o f used bat teri es acc ord ing to the m anufac turer ’ s
instructions.
Foreign matter
Do no t let met al obje cts fa ll insi de th e unit. T his
can c ause e lec tric s hock o r malfu nct ion.
Do no t let liq uids g et into th e unit . This c an cau se
ele ctr ic sho ck or m alfun cti on. If th is oc curs ,
imm ediate ly dis conn ect t he unit fr om the p ower
sup ply a nd con tac t your dea ler .
Do no t spray in sect ici des o nto or into th e unit.
They c ont ain fl ammab le ga ses whi ch c an ign ite if
spr ayed into the u nit.
Service
Do no t attem pt to rep air thi s unit by you rsel f.
If sou nd is inter rupted , indi cators fa il to light ,
smo ke appe ars, or any ot her pro ble m that is no t
covere d in the se ins truc tio ns oc cur s, dis conn ect
the AC ma ins le ad and c ontac t your d ealer o r
an aut hori sed ser vi ce ce ntre. Ele ctri c sho ck
or da mage to t he unit c an oc cur if t he uni t is
rep aired , disa ssem bled o r rec onstr ucte d by
unqualifi ed per sons.
Ex tend o perat ing li fe by disc onn ect ing th e unit
from t he power s ource i f it is not to b e used fo r a
long time.
Bac k of pro duc t
For your s afet y , pl ease re ad the fo llowi ng text
care ful ly .
Thi s app lianc e is su ppli ed wit h a moul ded t hree
pin m ains p lug for yo ur safet y and c onven ienc e.
A 5 -amp ere fus e is fi tted in t his p lug.
Sho uld th e fuse ne ed to be re plac ed ple ase
ens ure that t he rep lace ment fu se has a r ating of
5 -amp ere an d that it i s appr oved by AST A or BSI
to BS1 3 62.
Che ck for th e AST A mark or th e BSI mar k on
the b ody o f the fus e.
If th e plug c onta ins a re movabl e fuse c over you
mus t ensur e that it i s refi t ted whe n the fu se is
replace d.
If you l ose th e fuse c over the pl ug mus t not be
use d until a r epla ceme nt cover is o btai ned.
A rep lace ment fu se cover ca n be purc hase d from
your l oca l deal er .
CA UTION!
IF THE FIT TED M OULDED PLUG IS
UNSU IT ABLE FOR T HE SOCK ET OUT LET IN
Y OUR H OME THEN T HE FUSE SH OULD BE
RE MOVED AND THE PLUG C UT OFF AND
DIS POSED OF SAFEL Y .
THERE IS A DANG ER OF SEVERE
ELECTRICAL SHO CK IF THE CU T OFF
PLUG IS IN S ERTED INTO ANY 13-A MPERE
SOCKET .
If a new p lug is to be fi tte d plea se ob ser ve the
wiring code as stated below .
If in any d oubt p leas e cons ult a qu alifi ed
electrician.
IMPORT ANT
The w ires in t his mai ns lead ar e colo ured in
acc ord ance w ith th e followi ng co de:
Blu e: Ne utral, B rown : Live.
As th ese co lour s may not c orres pon d with t he
co loure d mark ings i dent ify ing th e termi nals in
your p lug, pro cee d as foll ows:
CA UTION FOR A C MAINS LEAD
Inform ation fo r Users o n Colle ction a nd Disp osal of O ld Equipme nt and us ed Bat teri es
The se symb ols o n the pro duc ts,
packaging, and /or acco mpanying
do cume nts me an that us ed ele ctr ica l
and e lec tron ic pro duc ts and b atter ies
sho uld no t be mixed w ith g enera l
household wast e.
For pr oper t reatm ent, re cover y
and r ecyc ling of o ld pro duc ts and
use d bat terie s, plea se take t hem
to applicable collection points,
in ac cor dan ce wit h your nat ion al
leg islat ion an d the D irec tives 20 02 / 96 /
EC an d 20 0 6 / 6 6 / EC.
By di spo sing of t hese p rodu cts a nd
bat terie s corr ect ly , yo u will he lp to
save valu abl e reso urce s and pr event
any pote ntial n egat ive ef fect s on
human health and the envi ronment
whi ch co uld oth erw ise ari se from
ina ppro priate wa ste hand ling.
For mo re infor matio n abo ut col lec tion
and r ecyc ling of o ld pro duc ts and
bat teri es, pl ease c onta ct your l oca l
mun ici palit y , your was te dis pos al
ser vi ce or t he poi nt of sal e wher e you
purchased the it ems.
Penalties may be applicable f or
inc orre ct di spo sal of t his was te, in
accordance with national legislation.
For bu sines s use rs in th e Europ ean
Union
If you wi sh to di scard e lec tric al and
ele ctr onic e quip ment , plea se cont act
your d ealer o r supp lier for f ur ther
information.
[ Inf ormat ion o n Disp osal i n oth er
Cou ntri es out side t he Euro pea n
Union]
The se symb ols are o nly vali d in the
Europ ean Uni on. If you wi sh to di scard
the se item s, ple ase co ntac t your lo cal
auth orit ies or d ealer an d ask for t he
cor rec t meth od of di spos al.
Not e for th e bat ter y symb ol ( bot tom
t wo symbo l examp les ) :
Thi s symbo l mig ht be use d in
co mbin ation w ith a ch emic al sym bol.
In th is cas e it co mpli es wit h the
req uirem ent set by t he Dire cti ve for the
chemical involv ed.
The w ire whi ch is c olo ured B lue mus t be
co nnec ted to the te rmin al whi ch is mar ked wit h
the l ette r N or col oured B lac k or Blu e.
The w ire whi ch is c olou red Brow n must b e
co nnec ted to the te rmin al whi ch is mar ked wit h
the l etter L o r col oured B rown or Re d.
W ARNING: DO NO T CONNECT EITHER WIRE
T O THE EARTH TERMINAL WHICH IS MARKED
WITH THE LETTER E, BY THE EARTH SYMBOL
OR COLOURED GREEN OR GREEN/
YELLO W .
THIS PLUG IS NO T W A TERPROOF—KEEP DR Y .
Before use
Rem ove the co nnec tor c over .
How to replace the fuse
The l ocat ion of t he fuse d if fer acc ordi ng to
the t yp e of AC mains p lug ( fi gure s A and B ).
Con fi rm th e AC mains p lug fi tted an d follow t he
instructions below .
Illu strati ons may d iffer fr om act ual AC main s plug.
1 . O pen t he fuse c over with a s crewdr iver .
Figure A Figure B
Fuse cov er
2. Re plac e the fu se and c lose o r atta ch th e fuse
cov er .
Figure A
Fuse (5 ampere)
Figure B
Fuse (5 ampere)
Note:
“EB ” on th e pack aging i ndic ates th e United K ing dom.
Panasonic Corporation
W eb Site: http://panasonic.net
Purs uant to at th e direc tive 20 04 /108 / EC , ar tic le 9 ( 2)
Panasoni c T es ting Cent re
Panasoni c Marketing Europ e GmbH
Win sberg ring 15, 22525 Ha mburg , Germ any
RQTX1189-2B
L0510CH2060
EB
En
1 Connect the speakers.
Be c are ful not to c ross ( sho rt- ci rcuit ) or r evers e the p olari ty of t he
sp eake r wire s as do ing so may d ama ge th e spe aker s.
2 Connect th e AM loop antenna.
Sta nd the a ntenna u p on its b ase.
3 Connect th e FM indoor antenna.
Plac e the ante nna wh ere rec ept ion is b est.
If th e radio r ece ption i s poor, use an o ptio nal outd oor ante nna. D isc onne ct th e FM indo or anten na.
Note:
• Thi s antenn a shou ld be in stall ed by a co mpete nt tech nic ian.
• Dis con nec t the ou tdoor a ntenna w hen th e unit i s not in us e.
• Do no t use the o utdo or antenn a duri ng a ligh tning s torm.
4 Connec t the A C mains le ad.
RE AD TH E CAUTI ON FOR AC MA INS L EAD O N THE L EF T BEFOR E CON NEC TI ON.
The i ncl uded AC ma ins le ad is for us e with t his uni t only. Do not us e it wit h other e quip ment .
Do no t use an AC mai ns lead fro m other e quip ment s.
Black
Red
Click !
T o hou seho ld
mains socket
FM outd oor ante nna
(not i ncluded)
75 c oax ial c able
(not i ncluded)
Use t he anten na
plu g adaptor
(included).
MAKING THE CONNECTIONS
ers a re des igne d ide ntic ally s o that n
■ Sal es and Su ppor t Inform ation
Customer Care Centre
• For cu stom ers wit hin th e UK: 0 844 8 44 3 852
• For cu stom ers wit hin th e Repu blic o f Irelan d: 01 289 8 33 3
• Vis it our web site for pr odu ct infor mati on w ww.pana soni c.co.uk
• E-mail : custo mer .care@pa nasonic.c o. uk
Dir ect Sa les at Pana soni c UK
• For cu stom ers : 08 44 8 44 3 856
• Ord er ac cess or y and c onsu mabl e items fo r your pro duc t with e ase an d con fi den ce by ph onin g our
Cus tomer Ca re Cent re Mon day- T hurs day 9 :0 0a m- 5: 30 pm, Frid ay 9: 3 0am -5 :3 0p m (E xclu ding p ubli c
holiday s).
• Or g o on line t hrou gh our Inte rnet Ac ces sor y ord erin g app licat ion at w w w .pas -eu rope.c om.
• Mo st majo r cred it and d ebit c ard s acc epted.
• All e nquir ies tra nsac tion s and di stri butio n facil ities ar e provid ed dir ect ly by Panaso nic UK Ltd .
• It couldn’t be simpler!
• Als o availab le thro ugh ou r Intern et is dire ct sh opp ing for a w ide ra nge of fi nish ed pro duc ts, ta ke a
brows e on our web site for fu rt her det ails.
PM02_EB.indd 1PM02_EB.indd 1 6/24/2010 5:52:01 PM6/24/2010 5:52:01 PM