Operation manual
4
U-5~18MX4 + U-8~16ME4
M + U-8~16ME4 + U-4~6ML5
Urban Multi air conditioner
4PW40727-1A
Explanation of heating operation
It may take longer to reach the set temperature for general heating
operation than for cooling operation.
The following operation is performed in order to prevent the heating
capacity from dropping or cold air from blowing.
Defrost operation
In heating operation, freezing of the outdoor unit coil increases.
Heating capability decreases and the system goes into defrost
operation.
The indoor unit fan stops and the remote controller displays
.
After maximum 10 minutes of defrost operation, the system
returns to heating operation again.
Hot start
In order to prevent cold air from blowing out of an indoor unit at
the start of heating operation, the indoor fan is automatically
stopped. The display of the remote controller shows .
It may take some time before the fan starts. This is not a
malfunction.
7.2. Program dry operation
The function of this program is to decrease the humidity in your
room with minimal temperature decrease (minimal room
cooling).
The micro computer automatically determines temperature and
fan speed (cannot be set by the remote controller).
The system does not go into operation if the room temperature
is low (<20°C).
For systems without cool/heat changeover remote control
switch (See figure 5)
1 Press the operation mode selector button several times and
select (program dry operation).
2 Press the on/off button.
The operation lamp lights up and the system starts operation.
3 Press the air flow direction adjust button. (Only for Double-flow,
Multi-flow, Corner, Ceiling-suspended and Wall-mounted.) Refer
to "7.3. Adjusting the air flow direction" on page 4 for details.
Stopping the system
4 Press the on/off button once again.
The operation lamp goes off and the system stops operation.
For systems with cool/heat changeover remote control switch
(See figure 6)
1 Select cooling operation mode with the cool/heat changeover
remote control switch.
2 Press the operation mode selector button several times and
select (program dry operation).
3 Press the on/off button.
The operation lamp lights up and the system starts operation.
4 Press the air flow direction adjust button. (Only for Double-flow,
Multi-flow, Corner, Ceiling-suspended and Wall-mounted.) Refer
to "7.3. Adjusting the air flow direction" on page 4 for details.
Stopping the system
5 Press the on/off button once again.
The operation lamp goes off and the system stops operation.
7.3. Adjusting the air flow direction
Refer to the operation manual of the remote controller.
Movement of the air flow flap (See figure 8)
For the following conditions, a micro computer controls the air flow
direction which may be different from the display.
The air flow direction can be adjusted in one of the following ways.
The air flow flap itself adjusts its position.
The air flow direction can be fixed by the user.
Automatic " " and desired position " ".
NOTE
The heating capacity drops when the outside
temperature falls. If this happens, use another
heating device together with the unit. (When using
together with appliances that produce open fire,
ventilate the room constantly.)
Do not place appliances that produce open fire in
places exposed to the air flow from the unit or
under the unit.
It takes some time to heat up the room from the
time the unit is started since the unit uses a hot-air
circulating system to heat the entire room.
If the hot air rises to the ceiling, leaving the area
above the floor cold, we recommend that you use
the circulator (the indoor fan for circulating air).
Contact your dealer for details.
NOTE
Do not turn off power immediately after the unit stops,
but wait for at least 5 minutes.
NOTE
Do not turn off power immediately after the unit stops,
but wait for at least 5 minutes.
A Double-flow + Multi-flow units
B Corner units
C Ceiling-suspended units
D Wall-mounted units
COOLING HEATING
•When the room temperature is lower than
the set temperature.
•When starting operation.
•When the room temperature is higher than
the set temperature.
At defrost operation.
•When operating continuously at horizontal air flow direction.
•When continuous operation with downward air flow is performed at the time of cooling with a
ceiling-suspended or a wall-mounted unit, the microcomputer may control the flow direction,
and then the remote control indication also will change.
NOTE
The movable limit of the flap is changeable.
Contact your dealer for details. (Only for Double-
flow, Multi-flow, Corner, Ceiling-suspended and
Wall-mounted.)
Avoid operating in the horizontal direction
"". It may cause dew or dust to settle on the
ceiling.
4PW40727-1A Page 4 Thursday, October 11, 2007 11:02 AM
6

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Panasonic U-16ME4 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info