551004
1
Zoom out
Zoom in
Vorherige Seite
1/2
Nächste Seite
The MONITOR OUT terminal output can be switched for NTSC or PAL monitors.
Installation Guide
Network Camera
Model No. WV-SFV631L/WV-SFV631LT
WV-SFV611L
WV-SFV631L
(This illustration represents WV-SFV631L.)
PGQX1455XA avs1213-2064 Printed in China
This manual describes the installation procedures, network camera installation, cable connec-
tions, and the angle of view adjustment.
Before reading this manual, be sure to read the Important Information.
This manual describes how to install the network camera using the WV-SFV631L model as an
example.
Major operating controls
The component names of the camera are as follows. Refer to the illustration when installing or
adjusting the camera.
Standard accessories Making connections
Important Information ............................... 1 pc.
Installation Guide (this document) ............ 1 set
Warranty card ........................................... 1 set
CD-ROM
*1
................................................. 1 pc.
Code label
*2
.............................................. 1 pc.
*1 The CD-ROM contains the operating instructions and different kinds of tool software pro-
grams.
*2 This label may be required for network management. The network administrator shall retain
the code label.
The following parts are used during installation procedures.
A Base bracket........................................ 1 pc.
C Fixing screws for attachment plate
(M4 x 8 mm) ...................................... 5 pcs.
(of them, 1 for spare)
G Template B (for the base bracket) .. 1 sheet.
I 2P power cable .................................... 1 pc.
K Waterproof tape ................................... 1 pc.
B Attachment plate .................................. 1 pc.
D 4P alarm cable ..................................... 1 pc.
E MONITOR OUT conversion plug ......... 1 pc.
F
Template A (for the attachment plate)
1 sheet.
H Bit ........................................................ 1 pc.
J LAN cable cover .................................. 1 pc.
H
K
How to initialize the camera
Follow the steps below to initialize the network camera.
1
Turn off the power of the camera. When using a PoE hub, disconnect the LAN cable from the cam-
era. When using an external power supply, disconnect the 2P power cable plug from the camera.
2 Turn on the power of the camera while holding down the INITIAL SET button, and then keep
holding down the button for 5 seconds or more. About 2 minutes later, The camera will start
up and the settings including the network settings will be initialized.
When data is being sent via the network camera Blinks green (accessing)
Turn off each system’s power supply before making a connection. Before making connections,
prepare the required peripheral devices and cables.
When the camera is able to communicate with the connected device
Lights orange
When an SD memory card*
1
is inserted and could Lights off Blinks green
be recognized Lights off
When data can be saved after the SD memory card is Lights off Lights green
inserted and the SD ON/OFF button is pressed
When data can be saved to the SD memory card Lights green
When the SD memory card is removed after holding down
Lights green Blinks green Lights off
the SD ON/OFF button for about 2 seconds
When data cannot be saved to the SD memory card because
Lights off
an abnormality was detected or the SD memory card is
configured not to be used
When AF (Auto Focus) operation is being executed
Blinks red (Interval of 1 time/ second)
When the set is being started Lights red
When an SD memory card is recognized normally Lights red Lights off
When an abnormality is detected in both SD1 and SD2
Lights red
cards after the camera has started
When an abnormality is only detected in the SD1 card Lights red Blinks red
after the camera has started (Interval of 1 time/ 3 seconds)
When an abnormality is only detected in the SD2 card Lights red Blinks red
after the camera has started
(Interval of 2 times/ 3 seconds)
IMPORTANT:
When the camera is initialized, the settings including the network settings will be initial-
ized. Note that the CRT key (SSL encryption key) used for the HTTPS protocol will not
be initialized.
Before initializing the settings, it is recommended to write down the settings in advance.
Do not turn off the power of the camera during the process of initialization. Otherwise, it
may fail to initialize and may cause malfunction.
IMPORTANT:
This is valid if the [Monitor out] is set to [Switch priority] ([Switch priority] is selected by
default). For details, refer to the Operating Instructions (included in the CD-ROM).
IMPORTANT:
Use all 4 pairs (8 pins) of the LAN cable (category 5 or better, straight).
The maximum cable length is 100 m {328 feet}.
Make sure that the PoE device in use is compliant with IEEE802.3af standard.
When connecting both the 12 V DC power supply and the PoE device for power sup-
ply, 12 V DC will be used for power supply*.
* If a 12 V DC power supply and a PoE hub or router are used at the same time, net-
work connections may not be possible. In this case, disable the PoE settings.
Refer to the operating instructions of the PoE hub or router in use.
*
In the situation where a 12 V DC power supply and a PoE hub or router are used at the
same time and the 12 V DC power supply is then disconnected, the power supply may
be stopped and the camera may restart depending on the PoE hub or router used.
When the LAN cable is disconnected once, reconnect the cable after around 2 seconds.
When the cable is quickly reconnected, the power may not be supplied from the PoE device.
When cables are used outdoors, there is a chance that they may be affected by lightning.
In this case, install a lightning arrester just before where the cables connect to the camera.
Connect a LAN cable (category 5 or better, straight)
Waterproof treatment for the cable joint sections
When connecting to a network using a PoE hub
Microphone/line input cable
Connect a monaural mini plug (ø3.5 mm).
Input impedance: Approx. 2 kΩ (unbalanced)
Recommended cable length: Less than 1 m {3.28 feet} (for microphone input)
Less than 10 m {32.8 feet} (for line input)
Recommended microphone: Plug-in power type (option)
Supply voltage: 2.5 V ±0.5 V
Recommended sensitivity of microphone: –48 dB ±3 dB (0 dB=1 V/Pa,1 kHz)
Input level for the line input: Approx. –10 dBV
IMPORTANT:
Be sure to use the 4P alarm cable provided with this product.
Off, input, and output of the external I/O terminal 2 and 3 can be switched by configur-
ing the setting. Refer to the Operating Instructions on the provided CD-ROM for fur-
ther information about the EXT I/O terminal 2 and 3 (ALARM IN2, 3) settings (“Off”,
“Alarm input”, “Alarm output” or “AUX output”).
When using the EXT I/O terminals as the output terminals, ensure they do not cause
signal collision with external signals.
Install external devices so that they do not exceed the ratings above.
Connect the alarm input/output cable
<Ratings>
ALARM IN1(DAY/NIGHT IN), ALARM IN2, ALARM IN3
Input speci cation: No-voltage make contact input (4 V - 5 V DC, internally pulled up)
OFF: Open or 4 V - 5 V DC
ON: Make contact with GND (required drive current: 1 mA or more)
• ALARM OUT, AUX OUT
Output speci cation: Open collector output (maximum applied voltage: 20 V DC)
Open: 4 V - 5 V DC by internal pull-up
Close: Output voltage 1 V DC or less (maximum drive current: 50 mA)
* The default of EXT I/O terminals is “Off”.
Connect an external amplifier-embedded speaker to the audio output cable
Connect a stereo mini plug (ø3.5 mm) (Audio output is monaural.).*
Output impedance: Approx. 600 Ω (unbalanced)
Recommended cable length: Less than 10 m {32.8 feet}
Output level: –20 dBV
IMPORTANT:
Connect/disconnect the audio cables and turn on the power of the camera after turn-
ing off the power of the audio output devices. Otherwise, loud noise may be heard
from the speaker.
Make sure that the stereo mini plug is connected to this cable. When a monaural mini
plug is connected, audio may not be heard.
When connecting a monaural speaker with amplifier, use a locally procured conver-
sion cable (mono-stereo).
Adequate waterproof treatment is required for the cables when installing the camera with cables
exposed or installing it under the eaves. The camera body is waterproof, but the cable ends are
not waterproof.
Be sure to use the supplied waterproof tape at the points where the cables are connected to ap-
ply waterproof treatment in the following procedure. Failure to observe this or use of a tape other
than the provided waterproof tape (such as a vinyl tape) may cause water leakage resulting in
malfunction.
Before starting the installation, check the entire system con guration. The following illustration
gives a wiring example of how to connect the camera to the network via a PoE device (hub).
<LAN cable> < Alarm input/output cable, power cable, micro-
phone/line input cable, audio output cable>
Wind the tape in a
half-overlapping manner.
Wind the tape in a
half-overlapping
manner.
IMPORTANT:
How to wind the supplied waterproof tape
Also waterproof the 2P power cable (accessory), 4P
alarm cable (accessory), and external connections in
the same way.
Stretch the tape by approx. twice (see the illustration)
and wind it around the cable. Insufficient tape stretch
causes insufficient waterproofing.
To prevent the LAN cable hook from coming loose
easily, fit the
J
LAN cable cover onto the pigtail
cable as illustrated, and then slide it in the direction
indicated by the arrow.
The connector of the LAN cable used with this cam-
era must meet the following restrictions.
Height when inserted (From bottom to hook.):
Max. 16 mm {5/8 inches}
Connector width: Max. 14 mm {9/16 inches}
To install this product outdoors, be sure to waterproof
the cables. Waterproof grade (IEC IP66 or equiva-
lent) is applied to this product only when it is installed
correctly as described in these operating instructions
and appropriate waterproof treatment is applied. The
internal parts of base brackets are not waterproofed.
2x
Stretch the tape to
about twice.
PoE device (hub)
PC
LAN cable
(category 5 or
better, straight)
Adjustment monitor
LAN cable
(category 5 or better,
straight)
LAN cable
(category 5 or better,
straight)
Powered speaker
Microphone
Powered speaker
Microphone
Adjustment monitor
Recommended total
extended cable length*
1
WV
-
SFV63
1L
WV
-
SFV631L
IMPORTANT:
The adjustment monitor is used for checking the adjustment of the angular field of view when
installing the camera or when servicing. It is not provided for recording/monitoring use.
Depending on the monitor, some characters (camera title, preset ID, etc.) may not be
displayed on the screen.
Use a switching hub or a router which is compliant with 10BASE-T/100BASE-TX.
If a PoE hub is not used, each network camera must be connected to a 12 V DC power
supply.
When using 12 V DC, power supply from a PoE hub or router is not required.
INITIAL SET button
Dehumidifying
device
Auto focus (AF) button
SD slot 1 (SD1)
SD slot 2 (SD2)
SD ON/OFF button
FRONT must posi-
tioned in front of the
camera (on the
Panasonic logo side).
Direction marker
for installation
(FRONT
)
Data Matrix: To our
website
*
2
Direction marker for installation
(
TOP
)
Points up when installing to a wall.
Dome cover
Light-blocking rubber ring
IR LED
Azimuth adjustment ring
Tilting table
Panning table
Camera fixing screw
The hook engages
with the connector
terminal
J
LAN cable cover
C
Fixing screws for
attachment plate
(accessory)
Enclosure
(Screw size 6.35 mm
{1/4 inches} torx wrench)
Camera
B
Attachment
plate (accessory)
A
Base bracket
(accessory)
ACT indicator
LINK indicator
SD MOUNT indicator
SD ERROR/AF indicator
*1 SDXC/SDHC/SD memory card is described as SD memory card.
*2
Depending on the scanning application used, the Data Matrix may not be able to be
read correctly. In this case, access the site by directly entering the following URL.
http://security.panasonic.com/pss/security/support/qr_sp_select.html
MONITOR OUT terminal
(factory shipment: NTSC
monitor)
D
4P alarm cable (accessory)
GND (black)
ALARM IN3, AUX OUT (gray) (Terminal 3)
ALARM IN2, ALARM OUT (red) (Terminal 2)
ALARM IN1, DAY/NIGHT IN (green) (Terminal 1)
Connect the output cable of the AC adaptor to the 2P power cable.
Power cable
12 V DC
Red Positive
Black Negative
WV-SFV631L
<Required cable>
LAN cable*
2
(category 5 or better, straight)
Use a LAN cable*
2
(category 5 or better, cross) when directly connecting the camera to a PC.
*1 Recommended cable length from the speaker: less than 10 m {32.8 feet}
Recommended cable length from the microphone: less than 1 m {3.28 feet}
*2 Shielded (STP) LAN cables must be used with this unit to ensure compliance with CE stan-
dards.
For U.S. and Canada:
Panasonic System Communications
Company of North America,
Unit of Panasonic Corporation
of North America
www.panasonic.com/business/
For customer support, call 1.800.528.6747
Two Riverfront Plaza, Newark, NJ 07102-5490
Panasonic Canada Inc.
5770 Ambler Drive, Mississauga,
Ontario, L4W 2T3 Canada
(905)624-5010
www.panasonic.ca
For Europe and other countries:
Panasonic Corporation
http://panasonic.net
Panasonic System Networks Co., Ltd.
Fukuoka, Japan
Authorised Representative in EU:
Panasonic Testing Centre
Panasonic Marketing Europe GmbH
Winsbergring 15, 22525 Hamburg, Germany
* Use an external powered
speaker.
Connect the power cable
Caution:
A READILY ACCESSIBLE DISCONNECT DEVICE SHALL
BE INCORPORATED TO THE EQUIPMENT POWERED
BY 12 V DC POWER SUPPLY.
ONLY CONNECT 12 V DC CLASS 2 POWER SUPPLY (UL
1310/CSA 223) or LIMITED POWER SOURCE (IEC/EN/
UL/CSA 60950-1).
IMPORTANT:
The 12 V DC power supply shall be insulated from the commercial AC power.
Be sure to use the 2P power cable provided with this product.
Be sure to fully insert the 2P power cable into the 12 V DC power supply terminal.
Otherwise, it may damage the camera or cause malfunction.
When installing the camera, make sure that excessive force is not applied to the
power cable.
Included Installation Instructions
© Panasonic System Networks Co., Ltd. 2014
WIDE button
(moves the camera to the “Wide” side)
TELE button
(moves the camera to the “Tele” side)
I
2P power cable (accessory)
RJ45 (female)
Network cable
Alarm input/output cable
Microphone/line input cable (white)
Audio output cable (black)
LAN cable (category 5 or better
straight)
4P alarm cable
(accessory)
Power cable
(12 V DC)
12 V DC (red)
GND (black)
Screen display
top (TOP)
NTSC/PAL switch
1

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Panasonic WV-SFV631LT wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Panasonic WV-SFV631LT

Panasonic WV-SFV631LT Bedienungsanleitung - Deutsch - 2 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info