GB GB
GB
GB GB
not performed by our authorized ser vice
branch will void the w arranty.
Procedure in t he case
of warranty
Please follow the instructions below to ensure
quick processing of y our claim:
Please retain pr oof of purchase and the arti-
cle number (e.g., IAN). The product number
can be found on the t ype plate, an engraving,
the cov er page of your instructions (bottom
left) or the decal at t he back or bottom. In
the ev ent of malfunctions or other defects
please first contact the service depar tment
below b y phone or e-mail. A product recor -
ded as defective, along with the proof of
purchase (sales receip t) and a description
of the defect and when it occurred, can the n
be returned free of char ge to you to the ser-
vice address pr ovided.
How to contact us:
GB
Name: C . M. C. GmbH
W ebsite: www.cmc-cr eative.de
E-mail:
ser vice.gb@cmc-creativ e.de
Phone: 0-808-189-0652
(Standard German land-
line charges)
Register ed office: Germany
IAN 96959
Please note that the following addr ess is not
a ser vice address.
Please initially contact the named Ser vice
Centres.
Address:
C . M. C . GmbH
K atharina-Loth-Str. 15
66386 St. Ingbert
Germany
Environmental instructions
and disposal infor mation
Don‘t waste, recycle!
Device, accessories and pack a-
ging should be recy cled in an
envir onmentally friendly manner .
Do not dispose of the air tool with your hou se-
hold waste, or thr ow into fire or w ater .
If possible, non-operational equipment should
be recy cled. Contact your local retailer f or
information.
EU Conformit y
Declaration
We ,
C . M. C . GmbH
Responsible for documentation:
Markus Zimmer
K atharina-Loth-Str. 15
66386 St. Ingbert
declare in our sole res ponsibilit y that the
product
Pneumatic t yre inflator
Serial number: 1727
Y ear of manufacture: 2014 / 32
IAN: 96959
Model: P ARKSIDE PNEUMA TIC T YRE
INFLATOR PDR A1
Complies with the following EU norms,
guidelines and directiv es:
Machiner y Directive
(2006 / 42 / EC)
applicable harmonised standards
NF EN 1953:2013
DIN 31000:2011-05
Using the pneumatic
t yre inflator
Connect the unit to a compressed air
supply .
Press the trigger
6
to start the air flow .
Release the trigger
6
to stop the air
flow . The air pressure can be r ead off
the pressure gauge
1
.
I f you hav e inflated too much air into the
article: Press the air release button
3
to
release some of the air .
Press the lev er down on the v alve plug
and pull off the valv e cap from the valv e.
D isconnect the unit from the compr essed
air source after finishing the work.
Warning: F irst of all, disconnect the tube
from the compr essor and when you have
done this, disconnect the supply pipe from
the unit. Follo wing these instructions will
stop the supply pipe from twirling ar ound
all ov er the place.
M
aintenance and Cleaning
DANGER OF INJUR Y
!
The device r equires no maintenance.
Do not use corrosiv e or aggressive cle-
aning agents. Do not allow an y liquids
to
enter the device. Otherwise t he device
could be damaged.
Clean the casing with a dr y cloth.
Ser vice
Only allow y our unit to be maintained and
ser viced by qualified service personnel. This
will maintain the safet y features of y our unit.
W arrant y
Creative Mark eting Consulting
GmbH warranty
Dear customer , the warranty for this device
is 3 years fr om the date of purchase. In the
ev ent of product defects you hav e legal ri gh t s
against the retailer of this pr oduct. Y our
sta tutor y rights are not limited in an y way by
our warranty detailed below .
W arrant y t erms
The warranty period begins on the date of
purchase. Please re tain the original receipt
safely . This document is required as your
proof of pur chase.
Should this device show an y fault in mater i-
als or manufacture within 3 year s from date
of purchase, it will be repair ed or replaced
- at our choice - by us fr ee of charge. This
warranty is conditional on the defective de-
vice and the receipt of pur chase being pre-
sented within the 3 year warr ant y period, and
that there is a brief written description of the
nature of the defect and of the date it arose.
If the defect is cov ered by our w arranty , we
will return the repair ed equipment or repla-
cement thereof. A repair or e xchange of the
equipment does not extend a ne w warranty
period.
Scope of warranty
The appliance has been manufactured to st
rict
qualit y guidelines and meticulously ex am i ne d
before deliv er y .
The warranty applies to faults in material or
manufacture. This guarantee does no t appl y
to product parts which are subject to normal
wear and tear and can be r egarded as wea-
ring par ts, or for damage to break able p ar ts,
e.g., switch, rechargeable batteries, or par ts
which are made of glass.
This warranty becomes void if the device has
been damaged or improperly used or main-
tained. All instructions pro vided in the ope-
rating instructions must be follo wed strictly to
constitute proper use of the pr oduct. Uses and
actions contrary to those set out in the opera-
ting instructions, and which are ill-advised or
warned against, must be av oided at all cost.
This product is intended for private, non-com-
mer cial use only . Any incorrect or impr oper
use of the device, use of for ce and changes
capacities are limited must ne ver be allo-
wed to use the de vice without super vis io n
or instruction by a person r esponsible
for their safet y . Please ensure that child-
ren cannot play with this unit.
Check the unit af ter
filling with compressed air using a tested
pressure gauge.
EXPLO-
SION HAZARD! Use this
device in w ell-ventilated areas
only . Never use petrol or other flamma-
ble liquids to clean the air tool! Sparks
could ignite residual v apours inside the
compressed air equipment r esulting in the
compressed air equipment e xploding.
RECOIL! When use d
under high pressure conditions, r ecoil
can
occur which can cause danger due to
constant pressurisation.
RISK OF INJUR Y!
Never point the air jet t owar ds yourself
or other people, animals, or electrical
equipment.
During maintenance, switch off the
compressed air supply .
Never e xceed the maximum permitted
operating pressur e of 10 bar . Use a
pressure r educer to adjust the operating
pressure.
Switch the device off if y ou do not use it
anymor e.
First of all, disconnect the tube fr om the
compressed air sour ce and when you
have done this, disconnect the supply
pipe from the unit. F ollowing these in-
structions will stop the supply pipe from
twirling around all ov er the place.
For y our own pro tection, please wear
suitable protectiv e clothing.
K eep children and other persons away
from the equipment during use.
Do not use the equipment when tired or
under the influence of drugs, alcohol or
medications. One moment of careles
sness
when using the equipment may result in
serious injuries. Distractions can cause
you to lose contr ol of the device.
Before any r epair and maintenance work
or transport, remov e the device from the
compressed air sour ce.
Before using the unit, check it for da
mage,
and especially for light damage or da-
mage to the protectiv e systems. These
must be thoroughly check ed to confirm
that they are indeed comple tely capa-
ble of performing their intended tasks.
All unit parts must be correctly assemble d
and comply with all guidelines in order
to ensure correct and safe oper ation.
If you ascertain that the unit is indeed
damaged, you ar e not permitted to use
it. Do not bend the unit’s pipe. This cou ld
cause damage.
Warning! Please observe all manu-
facturer’s instructions r egarding inflatable
articles.
Nev er remov e model numbers. They are
safet y-relev ant par ts of the unit. If you
have no e xperience of working with th is
unit, please undertake a training course
to acquaint you with the dangers of em-
barking on such a venture.
Original Accessories /
Auxiliar y equipment
Use only the accessories and attachments
detailed in the operating instructions.
Using other t ypes of additional parts
can cause danger .
Star t-up
Connecting the
compressed air source
Warning: Ne ver e xceed the maximum
permitted operating pressur e of 10 bar .
Warning: In order to regulate the pr essure ,
the compressed air sour ce must be fitted wit h
a pressure r egulator .
Connect the unit to a suitablecompres-
sed air source. No w connect the supply
pipe using the quick-release connect or to
the coupling plug on the pneu mati c tyr e
inflator .
Pneumatic t yre inflator PDR A1
Introduction
Congratulations!
Y ou have chosen high-quality de-
vice by our compan y . Familiarise
yourself with the pr oduct before using it for
the first time. In addition, please carefully
refer to the operating ins tructions and the
safet y advice below . Initial operation of this
tool must be performed by trained personnel.
K eep these instructions in a safe place. If you
pass the device on to an yone else, please
ensure that y ou also pass on all the docu-
mentation.
Intended use
With suitable accessories the pneumatic t yre
inflator can be used to pump up and regu-
late th e air pressur e in bicycle tyres, i nfl at ab l e
dinghies, air beds, balls, etc. This article is
not to be used contrary to the stipulated
co ndi ti on s o f intended use detailed in the in-
st ruc tio n lea flet. The manufacturer accepts
no responsibility for damage or injur y result-
ing from non-obser vance of the instructions
or from an y form of misuse. This device has
bee n des igned f or household use and may
no t be used for commercial or industrial pur-
poses.
Features
1
Pressure gauge
2
Pneumatic t yre inflator
3
Air outlet button
4
Compressed air nozzle
5
T ube with valve plug
6
T rigger
Scope of delivery
1 Pneumatic t yre inflator
1 Set of operating instructions
T echnical Dat a
Operating pressur e: max. 10 bar
Compressed air quality: Cleansed, oil-free
and free of con-
densation
V olume flow: Standard flow:
600 l / min.
Sound pressure le vel: 55 dB (A)
Acoustic capacity : 60 dB (A)
Measured v alue
Corresponds to: EN ISO 14462
Safet y information
Basic safet y measures
must be follow ed when using compressed
air devices to eliminate the risk of fire, ele ct r ic
shock and personal injury. Be sur e to read
and follow the notices within these opera-
ting instructions prior to using the equipment
and store them in a safe location. The ma-
nufacturer assumes no liability for damages
or personal injury resulting from failure to
follow these oper ating instructions.
Children or persons who lack the kno w -
ledge or experience to use the de vice or
whose phy sical, sensor y or intellectual
C . M. C . GmbH
Katharina-Loth-Str . 15
66386 St. Ingber t
Germany
V ersion des informations · Stand der
Informationen · Last Information Update:
06 / 2014 · Ident.-No.: PDRDA1062014-FR
St. Ingbert, 30.06.2014
K arl Peter Uhle
- Managing Director -
The following pictograms are used in t hese operating instructions /
on the equipment :
Please read the operating
instructions!
Never point the de vice at people
or animals.
Obser ve the w arning and
safet y instructions!
K eep children away fr om the
device!
W ear ear protection, dust
mask, safety glasses and
protectiv e glov es.
Dispose of packaging and de vice
in an environmentally-friendly way!
96959_par_Druckluft-Reifenfueller_(480x630)_FR.indd 2 27.06.14 12:53