25
Installation
General
The fitting of the appliance should only be
carried out by a registered Corgi gas fitter.
The appliance is not connected to the flue gas
outlet channel.
Electrical connection
or
without using the third phase.
Connect the appliance in accordance with the
sticker affixed to the rear of the oven.
■ The electrical connection must comply
with national and local regulations. For the
Netherlands this includes the NEN 1010
amongst other standards.
■ Wall socket and plug must be accessible at
all times.
Gasconnection: RC 1/2˝ (ISO 7/1-RC 1/2)
■ The gas connection must comply with
national and local regulations. For the
Netherlands this includes the GAVO
regulations (NEN 1078). Amongst other
things these regulations instruct that:
– only approved materials are to be used.
Please note:
The type of gas and the country for which the
appliance has been designed are indicated on
the ratings plate.
The appliance is set in the factory for G25
(natural gas) with a pressure of 25 mbar
Appliance category 12L.
■ Connect the oven directly to the mains.
This is because the oven can reach high
temperatures. It can also be connected
with a specially designed gas hose. Attach
this hose at the side of the oven to prevent
it touching any hot parts. A gas tap, which
is easily accessible, should always be used
for the appliance.
Attention:
Do not install a oven next to a high cupboard
or wall made of flammable material. (If there is
no alternative, ensure that there is a minimal
distance of 50 mm between the outer edge of
the oven and the wall in question (see fig. 11).
Also ensure that there is a minimum distance
of 650 mm between the oven and any
overhead extractor fan which may be
installed.
fig. 11